Responds to Noncompliance Noted in Insp Repts 50-289/89-22 & 50-320/89-10 Re Failure to Disqualify Armed Site Protection Officer Who Did Not Meet Min Physical Qualifications for Visual Acuity.Corrective Actions:Officer Removed from Duty
ML20011D437
Person / Time
Site: Crane  Constellation icon.png
Issue date: 12/21/1989
From: Hukill H
GENERAL PUBLIC UTILITIES CORP.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
4410-89-L-0126, 4410-89-L-126, C311-89-2139, NUDOCS 8912270214
Download: ML20011D437 (4)


Text

..

p' OPU Nuclear Corporation C

Nuolear

cm:

=

o ylddletown. Pennsylvania 17057 0191 147 944 7621 TELEX 64 2386 Writer's Direct Dial Nurnber:

December 21, 1989 C311-89-2139 4410-89-L-0126 U.S. Nuchar Regulatory Commission Attn:' Document Control Desk Washington, D.C.

20555

Dear Sir:

Three Mile Island Nuclear Station, Units 1 and 2 (TMI-1 & TMI-2)

Operating License Nos. DPR-50 and DPR-73 Docket No. 50-289 and 50-320 Response to Combined inspection Report 50-289/89-22 and 50-320/89-10 The subject Inspection Report identified one item of noncompliance concerning the failure to disqualify an armed Site Protection Officer who did not meet the minbum physical qualifications for visual acuity. Attached is GPU Nuclear's response to this item of noncompliance.

Sincerely, u 11 Vice Presijent & Director, TMI-1 HDH/RDW/spb:2139 cc:

R. Hernan W. Russell J. Stolz F. Young Attachment i

f 'n GPU Nuclear Corporation is a subsidiary of the General Public Utilities Corporation 0912270214 891221

!? " " C

ll EXHIBIT 1 g

t,Pu therdmar RESTRICTED OUTV Date Loost6on:

O Tui O OC O PAR 8 m NY Employee Name too6al Securtly No.

Estonolon JohnDoe 1

0 0

0 0 0 000 1001 Department DMe6en Security Adninistratian Supervisor Name Extere6on Joe Snith 1002 O acent O MET.ED G oPu NUCLEAR O CmLYTiC O OTNER

@ DUE TO MEDICAL CONDmON, THIS EMPLOYEE NAS BEEN PLACED ON THE PDLLOWING WORK RESTRICTIONS:

1. ftw Not Carry Weaoan (To achthalmnimint for follm-up or audiologist for follow to) 2, Itv Not Perform Strenuous Activity (To fantly physicim for folls up)

C PERMANENT ETEMPORARY 3 RECHECK AT MEDICAL DEPARTMENT 1 Week With doctor's note C MEDICAL CONDITION RESOLVED.

EMPLOVEE PHYSICALLY OUALIFIED FOR REQUIRED DUTIES.

C. Ocalock Medical Representative Signature Date 12-15-89 Dieveumon: whne. Supervoor Yellow. Employee's File N 830s (oHe)

p C311-89-2139 Attachment - Page 1 of 2 i

4410-89-L-0126 Item of Noncompliance "The NRC-approved Three Mile Island Security Personnel Training and Qualification Plan dated November 8,1985, Section 1.2.1.3, Armed Personnel Requirements, states, in part, that for each individual, distance visual acuity in each eye shall be correctable to 20/20 in the better eye and 20/40 in the otner eye with eyeglasses or contact lenses.

Contrary to the above, on October 11, 1989, during a review of medical records, an armed security officer, on duty: was identified with corrected visual acuity less than 20/40 in the weak eye.

me non-conforming visual acuity determination had been made and recorded by the licensee's medical department on May 26, 1989.

This is a Severity Level IV violation.

(SupplementIV)"

GPU Nuclear Response GPU Nuclear concurs with this item of nonenmpliance. The cause of this violation is attributed to the failure of the Medical Department to immediately notify the Security Department of the disqualification of a Site Protection Officer for armed duty.

The failure of GPU Nuclear to detect this event previously was due to the lack of accessibility to medical records by the Quality Assurance (QA) Department during performance of QA audits.

A.

Corrective Actions Taken The Site Protection Officer referred to in the item of noncompliance was removed from armed duty upon identification of this event. A QA audit c

(i.e., S-TMI-89-20 dated 12/5/89) was subsequently performed of the medical records of all armed Site Protection Officers to determine compliance with the medical qualification requirements of the NRC-approved Training and o

l Qualification Plan.

As noted in the subject Inspection Report, this audit L

identified an additional armed Site Protection Officer who failed to meet I

the minimum visual acuity requirements. This individual was also promptly l-relieved of armed response duties.

In addition to Site Protection personnel, the referenced QA audit also reviewed the medical records of licensed operators, crane operators, and individucis who utilize respiratory protection devices. This audit identified four (4) findings, which are currently being corrected.

B.

Corrective Actions Which Will Be Taken to Avoid Further Violations When an individual is disqualified for medical reasons, the Medical Department will issue a Restricted Duty Form (Exhibit 1) which will l

identify the specific work restrictions attributable to any failed physical

r:

1 e

i i

.. -C311-89-2139 Attachment - Page 2 of 2 4410-89-L-0126 i

requirement.

In the case of Site' Protection personnel, a copy of this form L

is immediately issued (i.e., same working day) to the Security Department and the Site Protection Officer. Additionally, the Medical Department notifies the Human Resources Department when an individual has failed a i

medical exam. The Human Resources Department then notifies the individual's supervisor, per Procedure 1000-ADM-2624.01.

Future QA audits will include direct examination of medical records pertaining to the minimum qualifications mandated by regulatory requirements considering the confidentiality of those medical records. GPU Nuclear believes these corrective actions should minimize the potential for similar violations.

C.

Date When Full Compliance Will Be Achieved i

Full compliance will be achieved by January 1,1990 at which time the above l

corrective actions will be fully implemented.

s I

.-