FVY-81-152, Forwards Yankee Atomic BWR Analysis Methods:Analysis of Typical BWR/4 Turbine Trip W/O Bypass Transients, in Support of Proposed Change 98

From kanterella
(Redirected from ML20011A771)
Jump to navigation Jump to search
Forwards Yankee Atomic BWR Analysis Methods:Analysis of Typical BWR/4 Turbine Trip W/O Bypass Transients, in Support of Proposed Change 98
ML20011A771
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 10/30/1981
From: Rich Smith
VERMONT YANKEE NUCLEAR POWER CORP.
To:
Office of Nuclear Reactor Regulation
Shared Package
ML20011A772 List:
References
FVY-81-152, NUDOCS 8111030136
Download: ML20011A771 (1)


Text

VERMONT Y AN KME NUCLEAR POWER CORPORATION SEVENTY SEVEN GROVE STRC$?

2.C.2.1 RUTLAND, VERMONT 05701 EVY 81-152 MEPLY TO:

ENGINEERING OFF!CE 167* WORCESTER ROAD FRAMINGH AM M ASSACHUSETTS O1701 T E L Ec" HON E 817 872 8100 A

October 30, 1981

~

I%o

)?

\\eh United States Nuclear Regulatory Commission j

/g Washington, D. C.

20555 Atten tion :

Orlice cf Nuclear Reactor Regulation Ah' '

References:

(a) License No. DPR-28 (Docket No. 50-271)

(b) Letter, USNRC to VYNPC, dated October 23, 1981 (c) Letter, VYNPC to USNRC, FVY 81-128, dated September 2,1981

Subject:

Supplemental Information in Support of Proposed Change No. 98 - Reload Licensing Submittal

Dear Sir:

This letter provides the information requested in Reference (b). This informat!on is contained in the attached report, YAEC 1280 - Yankee Atomic Boiling Water Reactor Analysis Methods: Analysis af a Typical BWR/4 Turbine hip Without Bypass Transient.

We trust that this information vill aid you in completing your review of Reference (c) in a timely manner. Should you have any further questions, please con tact us.

Very truly yours, VERMONT YANKEE NUCLPJM POWER CORPORATION R. L. Smith CD Licensing Engineer s

RLS: dad

/ /D Attacnmen t f

8111030136 811030 PDR ADOCK 05000271 P

pop

,