Forwards Discussion Re Required Concessions to Technical Requirements for Completion of NUREG-0737 Mods by Startup Following Sept 1982 Outage.Typical Equipment Procurement Schedules Also Encl
ML20011A620
Person / Time
Site: Rancho Seco
Issue date: 10/08/1981
From: Mattimoe J
SACRAMENTO MUNICIPAL UTILITY DISTRICT
To: Novak T
Office of Nuclear Reactor Regulation
References
RTR-NUREG-0737, RTR-NUREG-737, TASK-***, TASK-TM NUDOCS 8110290191
Download: ML20011A620 (4)


Text

_

f~

/

D Oc.N.El 5t ~5\\i

~

October 8i 1981 TO: TOM NOVAK

~ '

ASSISTANT DIRECTOR i

OPERATING REACTORS.

tc s

+

On' September 17, 1981, we discussed ouk schedule fo' r completion of the remaining NUREG-0737 modifications at. Rancho Seco with you and other members of the NRC staff t. We indicated that some concessions to the technical requirements would be required in order for us to have the requirements completed by startup :following a September 1982 shutdown.

.These concessions revolve around the power requirements of the TMI modifications and are discussed in Attachment 1.

~

We also discussed the level of. manpower which has been devoted to these-modifications and would like to reiterate the fact that our entire Generation Engineering staff was devoted to these modifications following the Three-Mile Accident, except as required by other NRC requirements.

An example of competing requirements on our manpower are the 79-01 B

. e estimate an expenditure W

Electrical Equipment Qualification efforts.

of $600,000 for the study required by this bulletin and have budgeted

.$4,000,000 for replacing. equipment.

Five SMUD-engineers and six consulting engineers have been assigned to this project. Of course, all projects cannot be started at one. time, but must follow each other in some logical sequence. Recently, our Operating Department has had to devote manpower to outages relating to steam generator tube leaks and.

Our turbine failure. This has interfered with our inhouse safety review.

process in many cases.

0ur problems pertaining to equipment procurement' and the~ dasign effort.

required. prior to publishing a bid specification were discussed during our meeting. Attachment 2 provides some examples of procurement schedules.

O D

/ud' W

w'\\

1 0

S m e%y%

4 m

$ NfWin 34y h y \\ y %g%[ggb e11o290191 stime n <g pe -c--g

A. .ATTACHMFNT 1 POSSIBLE SCHEDULE IMPROVEMENTS The power requihements for the implementation of NUREG-0737 items have established a need for' additional emergency power-suppl _ies at Rancho Seco Uni t-.l. The~ District has, awarded a contract for the purchase of two additional diesel generators, whose installation,in turn, ieads to the're-quirement for a class I structure:to hou'se the units and a class I cooling pond for unit cooling. The total cost of this addition is some $40 million and we find it impossible to complete this effort,until the 1984 refueling octage. The main power requirement comes from the need to automatically ~ 1oed our existing auxiliary fe'edwater pump motors onto emergency diesel: busses. Regulatory Guide 1.9 provides minimum acceptable voltage and frequency drops during an automatic loading sequence. Our frequency is expected to drop about 1 H z below these minimum requirements and the exact-amounts would have to be determined from system testing. If NRC allowances-are made to allow for this~ deviation, it.might be possible for the _ District to eliminate the addition of'the new diesel generator system. In addition, the power requirements for control room habitability probably cannot be met and concessions may have to be made in the design of redundant heating, venti-lating, and air conditioning units. The power available for eavironmental control of-the new Nuclear Service Electrical Building may also havelto be lessened, requiring additional equipment qualification efforts for equipment being installed in this building. Most likely, this effort could not be com-pleted until some time after the September 1982 outage. (


a-n_.-------a., _ _,

~ ATTACHMENT 2 -TYPICAL EQUIPMENT PROCUREMENT SCHEDULES The Sacramento Municipal Utility District is a public agency and must purchase equipment according to State law. All purchases of over $10,000 must be made by-~ competitive bid and must be approved by the Board of Directors, who meet twice each month. This requirement makes extra front-end engineering necessary to prepare bid specifications suitable for the purchase of equipment meeting all District and NRC requirements. The following are examples. of procurement schedu bc. I ' Reactor Coolant System Solenoid Operated Vent Valves A. Initiate development of design criteria (B&W) 8/20/79 'B. ' Completion of design criteria l?/3i/79 C. Begin system design effort (Bechtel) 2/21/80 D. Start preparation of bid specificatior. 4/1/80-E. Bid release 9/5/80 F. Bid opening 10/1/80 G. Award 10/17/80 H. Original delivery schedule 5/21/81 I. Present forecast delivery date 2/7/82 -II. Auxiliary Feedwater System Valve Modification A. Initiate reliability study of auxiliary feedwater system (B&W) 8/21/79 B. Complete reliability study 12/17/79 C. Attempt to -purchase motor operator for existing valve for 4/1/82 installation 11/80 D. Valve vendor would not provide operator and new bid specification work initiated 2/1/81 E. Bid Release (forecast) 10/15/81 F. ' Award (forecast) 12/1/81 G. Delivery (specified) 6/1/82 III. Expansion of Class IE Electrical Power System A. Bechtel ' Task'~ initiated - 5/8/80 i B. Start preparation for bid spec for 4160 volt switchgear. 8/80 1. Bid Release 3/26/81 2. Bid Opening 5/7/81

3.. Award 7/2/81

-4. . Estimated Delivery 4/30/82

c. =

r. C. Start preparation of bid specifications for 480 volt load centers 8/80 1. Bid Release 3/12/81 2. Bid Opening 4/16/81 3. Award 6/19/81 4. Estimated Delivery 3/12/82 IV. Essential Water Chillers A. Start preparation of bid specification 7/26/80 B. Bid Release 7/27/80 C. Board authorization to negotiate a contract based on the fact that only one bid was received and it was non-responsive 9/17/81 D. Award (forecast) 11/5/81 E. Delivery (forecast) 9/15/82}}