ML20011A594

From kanterella
Jump to navigation Jump to search
Forwards LER 81-094/03L-0
Date released: 01/25/2020 Download: ML20011A594


LER 81-094/03L-0:on 810921 & 27,diesel 2C Failed to Reach Rated Speed & to Respond to Speed Control When Shutdown Attempted.Caused by Low Oil in Diesel Governor & Shorted Brush in Governor Control Motor
ML20011A599
Person / Time
Site: Hatch 
Issue date: 10/20/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20011A599 (2)
Forwards LER 81-094/03L-0
ML20011A593
Person / Time
Site: Hatch 
Issue date: 10/20/1981
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20011A593 (1)