ML20011A157
| ML20011A157 | |
| Person / Time | |
|---|---|
| Issue date: | 03/02/1973 |
| From: | William Allen NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | |
| Shared Package | |
| ML20008D735 | List: |
| References | |
| FOIA-81-311 NUDOCS 8110070485 | |
| Download: ML20011A157 (1) | |
Text
r Po mas a C-cst UI E3 STATES ATOMIC ENERGY COMMIS5tC48 i 4
- OtVISepN OF COMPLIANCE
- Di
(
INSPECTION FINDINGS AND LICENSEE ACKNOWLEDGMENT g, g,3CsMges
- 3. R E GION AL. O FF AC E Departiment of The Atwy U.S. Atomic Energy Commsission Army Materials di unehemies Ramearch Dir==*ar=*= ef Eegolatary Operations Watertesses Massachusetts Regien 1 970 Broad street usuark. new Jewy 07102
- s. pocGuy osumssents) 4.s.scsMos Mus.amants)
- s. DATE Or sMsencTIoM 20 01010-04
/m..
l gD_
- /!*r.
u/'
4
- e. BMsPEr: TION FINDINGS The inspection was an examination of the activities conducted undee your license as they relate to radiation safety and to compliance with the '
Commission's rules and regulations and the conditions of your license. The inspection consisted of selective examinations of procedures and repre-sentative records, interviews with personnel, and observations by the inspector. The findings as a result of this inspection are as follows:
ho items of noncompliance or unsafe conditions were found.
The following iterr.s of noncompliance related to records, signs, and labels were found:
O A. Rooms or areas were not properly posted to indicate the presence of a RADIATION AREA.10 CFR 20.203(b)or 34.42 O
B. Rooms or areas were not properly posted to indicate the presence of a HIGH RADIATION AREA.
10,CFR 20.203(c)(1) or 34.42
~_
C.jRooms or areas were not properly posted to indicate the presence of an AIRBORNE RADIOACTIVITY AREA.
OD.1(oomter areas were not properly posted to indicate the presence of RADIOACTIVE MATERIAL.10 CFRf20.203(e).
.s Sv O 'Ec.Cc.ntainers were not roperly labeled to indicate the presence of RADIOACTIVE MATERIAL.
~[
C MT
~
10 CFR 20.203(f)(1 or (f)(2) '
m,<
O JF. A current copy of 10 CFR 20,a copy of the license, or a copy of the operating procedures was not prtfp'e'rly posted or
=
' ' r
.made available.10 CFR 20.206(b)
- . l t
G. Form AEC-3 was not properly posted. 20 CFR 20.206(c)
II. Records of the radiation exposure ofindividuals were not properly maintained.10 CFR 20.401(a) or 34.33(b)
O
- 1. Records of surveys or disposals were not properly maintained.10 CFR 20.401(b)ir 34.43(d)
J. Records of receipt, transfer, disposa". aport or inventory oflicensed material were not properly maintained.
10 CFR 30.51,40.61 or 70.51 K. Records ofleak tests were not maintained as prescribed in your license, or 10 CFR 34.25(c)
L. Records ofinventories were not maintained.10 CFR 34.26 O
M. Utilization logs were not maintained.10 CFR 34.27 N. Records of radiation survev mstrument calibratio'n were not maintained.10 CFR 34.24 O. Pecords of teletherap3 electrical interlock tests were not maintained as prescribed in your license.
O P. Other
-- =--- - -
i J w w a
m h MM 1 ~*c -s J (A EC Compliance inspectorl C -~~. w, r 7 The AEC Compliance Inspector has explained and I understand the items of noncompliance listed above.The items of noncompliance will be corrected within the next 30 days.
,J.E9%
s li M ,
(Licensee Representative - Title or Position)
(Date) l ORIGINAL TO LICENSEE 8110070485 010Ei18 PDR FOIA SULLIVA81-311 PDR
~