Interim Deficiency Rept Re Error in Assumptions Used in Modeling Load Transfer from Crossover Leg Restraint to Fill Slab & Containment Basement,Initially Reported by Bechtel on 810821.Final Rept Will Be Submitted by 811106
ML20010J041
Person / Time
Site: Vogtle  
Issue date: 09/17/1981
From: Foster D
GEORGIA POWER CO.
To: James O'Reilly
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
10CFR-050.55E, 10CFR-50.55E, GN-145, NUDOCS 8109290538
Download: ML20010J041 (2)


Text

a,

Georgia Power Company Post Office Bon 4545 h

Atlanta, Georgia 30302 Telephone 404 522-6060

.) '

)

Southern Company Services. Inc.

.\\

g

(

Post Office Boa 2625 Birmmgham, Alabama 35202

(% /

'l/

Telephone 205 870-6011 g

V C

[c,$.g%

h f

9~ '

,s Q 4

{

- u} -

,a E'

9 September 17, 1981 Q 'O

\\f4 4

~t S, W.s_ ]l United States Nuclear Regulatory Commission

.'/

Office of Inspection and Enforcement Region II - Suite 3100 101 Marietta Street File:

X7B603 M19 Atlanta, Georgia 30303 Log: GN - 145

Reference:

50-424, 50-425; Design Calculations Concerning Primary Loop Crossover Leg Pipe Restraints Attention: Mr. James P. O'Reilly Gentlemen:

Georgia Power Company has evaluated the conditions associated with the assumptions used in modeling the load transfer from the cross-over leg restraint to the fill slab and containment basemat.

It has been concluded that an error in the assumptions used for modeling constitctes a reportable deficiency. AddiH-'1 ally, Bechtel Power Corporation by letter dated August 21, 1981, has reported this event as a substantial safety hazard to Mr. Karl Seyfrit of the NRC, Region IV.

Georgia Power Company is submitting this report as an interim l

report and expects to submit a final report by November 6,1981.

This report contains no proprietary infomation and may be placed in the NRC Public Document Room upon receipt.

Sincerely,f e

/

/

D. i0 Foster Project General Manager CWH:tlp Tb s

ih 8109290538 810917 PDR ADOCK 05000424 S

PlR

i Mr. James P. O'Reilly 50-424, 50-425; Containment Liner Penetrations - Unit 1 September 17, 1981 page two xc:

~U. S. Nuclear Regulatory Commission Attn: Victor J. Stello, Jr., fairector j

Office of Inspection and Enfor:ement i -

Washington, D.C.

20555 J. H. Miller, Jr.

R. J. Kelly.

R. E. Conway G. F. Head i

R. H. Pinson C. F. Whitmer i

D. L. McCrary R. A. Thomas- --

i J. A. Bailey O. Batum i-D. E. Dutton K. M Gillespie i

E. D. Groover l-L. T. Gucwa B. L. Lex C. R. Miles, Jr.

H. C. Nix i

R. W. Staffa

'J. L. Vota 4

i I

I f

I i

i l

i i

i L

.