Forwards LER 81-022/03L-0
Date released: 01/24/2020 Download: ML20010H744


LER 81-022/03L-0:on 810902,vessel low-low Water Level Isolation Switch Had Setpoint of 116.8 Inches,Exceeding Tech Spec Limit.Caused by Instrument Setpoint Drift.Setpoint Adjusted
ML20010H751
Person / Time
Site: Dresden Constellation icon.png
Issue date: 09/18/1981
From: Schroeder B
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010H751 (2)
Forwards LER 81-022/03L-0
ML20010H743
Person / Time
Site: Dresden Constellation icon.png
Issue date: 09/18/1981
From: Scott D
COMMONWEALTH EDISON CO.