ML20010G852

From kanterella
Jump to navigation Jump to search
Forwards LER 81-076/01T-0.Detailed Event Analysis Encl
Date released: 01/24/2020 Download: ML20010G852


LER-81-076/01T-0:on 810902,NRC Notified of Svc Water Leaking from Secondary Coil on Containment Fan Coil Unit (Cfcu) 14, Per IE Bulletin 80-24.CFCU Removed from Svc & Declared Inoperable.Caused by Secondary Coil Failure
ML20010G873
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/14/1981
From: Dickey F
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20010G873 (1)
Forwards LER 81-076/01T-0.Detailed Event Analysis Encl
ML20010G851
Person / Time
Site: Salem PSEG icon.png
Issue date: 09/14/1981
From: Midura H
Public Service Enterprise Group
To: HAYNES R C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20010G851 (3)