ML20010G452

From kanterella
Jump to navigation Jump to search
Forwards LER 81-077/01T-0.Detailed Event Analysis Encl
Date released: 01/24/2020 Download: ML20010G452


LER 81-077/01T-0:on 810902,operator Discovered Svc Water Leaking from Secondary Cooling Coil on Containment Fan Coil Unit 11.Caused by Pinhole Leak in Secondary Coil.Leak Brazed Over
ML20010G460
Person / Time
Site: Salem 
Issue date: 09/08/1981
From: Dickey F
Public Service Enterprise Group
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20010G460 (1)
Forwards LER 81-077/01T-0.Detailed Event Analysis Encl
ML20010G451
Person / Time
Site: Salem 
Issue date: 09/08/1981
From: Midura H
Public Service Enterprise Group
To: HAYNES R C
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20010G451 (3)