ML20010F872

From kanterella
Jump to navigation Jump to search
Response to ASLB 810825 Order Re ASLB Notification of Unsatisfactory Test Results of Safety Valve.Failure Did Not Have Significant Application to TMI-1 Due to Significant Variance Between TMI Control Ring Settings & Those Tested
Date released: 01/24/2020 Download: ML20010F872


Affidavit That General Public Utils Determined That Failure to Meet Test Screening Criteria Provides No Basis to Doubt TMI-1 Pressurizer Safety Valve Performance of Safety Function.Certificate of Svc Encl
ML20010F873
Person / Time
Site: Crane Constellation icon.png
Issue date: 09/04/1981
From: Correa J
METROPOLITAN EDISON CO.
To:
References
Download: ML20010F873 (7)
Response to ASLB 810825 Order Re ASLB Notification of Unsatisfactory Test Results of Safety Valve.Failure Did Not Have Significant Application to TMI-1 Due to Significant Variance Between TMI Control Ring Settings & Those Tested
ML20010F871
Person / Time
Site: Crane Constellation icon.png
Issue date: 09/04/1981
From: Baxter T
METROPOLITAN EDISON CO., SHAW, PITTMAN, POTTS & TROWBRIDGE
To:
Atomic Safety and Licensing Board Panel
References
Download: ML20010F871 (3)