ML20010E701

From kanterella
Jump to navigation Jump to search
Forwards LER 81-085/03L-0
Date released: 01/24/2020 Download: ML20010E701


LER 81-085/03L-0:on 810805,reactor Core Isolation Cooling Steamline Switch Found to Actuate Above Tech Spec Limit. Caused by Setpoint Drift.Barton Model 288 Recalibr & Returned to Svc
ML20010E703
Person / Time
Site: Hatch 
Issue date: 08/25/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010E703 (2)
Forwards LER 81-085/03L-0
ML20010E700
Person / Time
Site: Hatch 
Issue date: 08/25/1981
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20010E700 (1)