Forwards H Dieckamp Requesting Reversal of Director of Nuclear Reactor Regulation 810817 Decision Requiring re-exam of All TMI-1 Licensed Operators.Decision Imposes New Restart Requirement.W/Certificate of Svc
ML20010D209
Person / Time
Site: Crane 
Issue date: 08/20/1981
From: Trowbridge G
SHAW, PITTMAN, POTTS & TROWBRIDGE
To: Jordan W, Little L, Smith I
Atomic Safety and Licensing Board Panel
Shared Package
ML20010D210 List:
References
NUDOCS 8108240101
Download: ML20010D209 (4)


Text

.

p--m-g PTC D. S U TI L. ; 7. 0,...,...s

. l.......,

SHAW, PITTM AN, PoTTs & TROWBRIDGE 18 00 M STR E CT, N, W.

WASHIN GTO N, D. C. 20036 TELERMONE TELEcopIER WRITER O ECT AL NUMBER

rea, i

89-2893 (SMAwLAw WSM)

C A BLE "sMawLAw'*

El (m:3 5

ON>

August 20, 1981

(

OfRe of the Secgreta 6

\\

0::keti.cg & se Oh Dr. Walter H.

Jordan Ivan W.

Smith, Esquir g

Chairman Atomic Safety and Licensing Board Atomic Safety and Licensing Board 881 West Outer Drive U.S.

Nuclear Regulatory Commission Oak Ridge, Tennessee 37830 Washington, D.C.

20555 s

Dr. Linda W.

Little

' Ogf'gv.

Atomic Safety and Licensing Board g @./ _

5000 Hermitage Drive N

Raleigh, North Carolina 27612

~_

q,1h)d /'3 3; y

/s ' 4

%?

Metropolitan Edison Company

/ /cb O,\\( /

In the Matter of Tf;-

(Three Mile Island Nuclear Station, Unit No. 1)

Docket No. 50-289 Restart I

Dear Chairman Smith and Administrative l

Judges Jordan and Little:

l l

We are enclosing for your information a letter sent today to the Chairman of the NRC from Herman Dieckamp, President of General Public Utilities Corporation.

Mr. Dieckamp's letter asks the Commission to reverse the decision reached by the Director of Nuclear Reactor Regulation (NRR) and communicated to Mr. Dieckamp on August 17, 1981, to require reexamination of all of the TMI-l licensed (or candidate) operators who successfully passed the NRC l

written examinations given last April.

1 l

Since the Director's decision can be viewed as imposing a new restart requirement which Licensee would be entitled to liti-gate before the Licensing Board, before embarking on the present course of action we considered taking the matter initially to the Board, rather than to the Commission.

The decision to raise the issue directly with the Commission was based upon the following considerations:

03 3

lb 8108240101 810820 PDR ADOCK 05000289 PDR o

o SHAW, PITTMAN, POTTS & TROWBRIDGE August 20, 1981 Page Two 1.

NRR intends to administer the licensed operator reexam-inations a'few days in advance of the operator oral exams, which are presently scheduled for September, 1981.

Time is therefore of the essence.

Direct review of the NRR decision by the Commission appears to be the only practicable course of action available to us.

2.

We believe the Commission can make a decision on the matter based on the several factual investigations conducted by the l

Staff without the development of a further evidentiary record by the Licensing Board.

In fact, Mr. Dieckamp's letter to the Commis-sioners does not take issue with the factual findings reached in the investigative reports issued by the Office of Inspection and Enforce-ment and by the Office of Inspector and Auditor but, rather, bases its objections upon them.

3.

Finally, we have taken into account the Staff's handling i

of the reexamination issue, which so far as the Board is concerned consisted of informing the Board of the investigative efforts under-way, the results of the investigations, and NRR's proposed action.

The Staff sought no action by the Board.

Clearly, the Staff was of the view that the reexamination issue is severable from the restart hearing; in fact, Mr. Denton indicated to Mr. Dieckamp that he felt at liberty to and did discuss the matter with Chairman Palladino prior to making his decision.

In summary, we are forwarding the attached letter to you in order to keep you fully apprised of a matter pending before the Com-mission which could bear on the restart of TMI-1.

i Si

rely,

./

e F.

rowbridg cc w/ attachment:

I Chairman Palladino Commissioner Gilinsky 1

Commissioner Ahearne Commissioner Bradford Commissioner Roberts TMI-l Restart Hearing Service List 1

- - -,,,., - - - _ - - - ~.. - -.,,,.

n..,---

. -. ~,. -


,-.--n

Cd1 pq

/

t,s.

/ :

a.

y

&f% 2 01981 e, 'I, l em f'

C[.:- C n. p..g.7.j l

L:e..n: :.. b ;_

y (AS f;D)'

UNITED STATES OF AF. ERICA NUCLEAR REGULATORY COMMISSION co ld BEFORE THE ATOMIC SAFETY AND LICENSING 30ARD In the Matter of

)

)

METROPOL'[ TAN EDISON COMPANY

)

Docket No. 50-28.:

)

(Restart)

(Three Mile Island Nuclear

)

-Station, Unit No. 1)

)

SERVICE LIST Ivan W. Srith, Esgaire Jchn A. Imvin, Esqaire CW m Assisrant Counsel Atcmic Safety and Licensirs Pennsylvania Public Utility Ci m'n sca_d Panel Post Cffice Scx 3265 U.S. Nuclear Pegulatcry Ccnreissicn Earrisburg, Pe:r.sylvania 17120 Washir.= ten, D.C.

20555 Earin W. Carter, Esgaire cr. Waltar H. Jordan Assistant Attcrnev Geraral Atcmic Safety ad Licensirs 505 Executive Ect5e Scard Panel Post Office Scx 2357 881 West Outer Drive F - isburg, Pennsylvania 17120 Ca% Pidge, Tennessee 37830 John E. I'Annich Dr. Linda W. Iittle c'.ai:c an, Daups ccunty Beard Atcrcic Safety ard Licensirs of Ccnrissicners Scard Panel Dauphin Ccunry Ccurthcuse 000 Herritage Mve

.ht anf Market Streers 1

Paleigh, North %1ina 27612 Earrishcrg, Pennsylvan'ia 17101 Ja:ms R. Tcurtellette, Esquire Walter W. Cchen, F @ e Office of the Executive Imgal Directcr Ccnstrmr Idva: ate Office of Ccn. t_rer Advocate U. S. Nuclear Pegulatory Ccrrissien s

l Washing cn, D.C.

20555 14th Flccr, Straterry Secare Harrisburg, Pennsylvaria 17127 Cocke & q and Service Secticn Office cf the Secretary U. S. Nucla"- Pegulatory Ccnrissica Washington, D.C.

20555

o.

O 2-s Jordan D. C = ningb2.m, Esgaire M' Eradford At wrney for Newberry Tcw ship A= i-Nuclear Group Fepresen & g Ycrk T.M.I. Steeri.g Cm mittee 245 West Philadelpbla Street Fcx, Farr & C=ningham Ycrk, Pe_.nsylvaria 17404 2320 Nc-d Second Street Harrisburg, Pennsylvania 17110 W4 4 = n S. Jc dan, m, Esgaire Attorney for Pecple Isainst Nuclear Ms. Louise BrM #crd

.ergy

'IMI AI..C Fmn & Weiss 315 Peffer Street 1725 Iye Street, N.W., Suite 506 Earrish=g, Pennsylvania 17102 Washington, D.C.

200s Attorney General of New Jersey e

F&ert Q. Pollard ALu:

?.c=as J. Gemine, Esgaire 609 Mcntpelier Street ceputy Attorney General Baltimore, Maryland 21218 Division of Iaw - Ponn 316 1100 Bayrend Eculevard Chauncey Kepferd Newark, New Jersey 07102 Judith E. Johnsrd Envi_u... ental Ccalition en Nuclear Ellyn R. Feiss, Isgaire Pcuer At crney. for the Crica cf Ccncerned 433 Criando Ave =e Scientists State College, Pennsylvania 16801 Harren & Feiss 1725 Eye Street, N.W., Suite 506 Pa.rrin I. Iscis Washingtcn, D.C.

20006 6504 Eradford Terrace Phi' v lphia, Pennsylvania 19149 e

Steven C. Sholly Urien of Ccncerned Scientists Ma.d crie M. Aaroit 1725 Eye Street, N.W., Suite 601 P.. D. 5 Washingtcn, D.C.

20006 Ccatesville, Pennsylvania 19320 M

e pO4 e

e 8

_