w.

.C V

Deholt Edison saw u, 2000 Second Aven 1

i i

l August 14, 1981 EF2'- 54263 Mr. L. L. Kintner U. S. Nuclear Regulatory Commission Division of Project Management Office of Nuclear Recctor Regulation 7920 Norfolk Avenue Bethesda, !k.ryland 20014 Dear Mr. Kintner

Reference:

Enrico Fermi Atomic Power Plant, Unit 2 NRC, Jacket do. 50-341

Subject:

Reve n. Aoting of Butterfly Valves During telecon with your John Lane on August 13, 1981, the request was made for documents supporting the conservatism of reverse test-ing of butterfly valves.

In response to this request, enclosed are:

1.

Janesbury Corporation letter to Edison, May 15, 1979 2.

Detroit Edison mno EF2-45091, Revicion A, June 4, 1979 3.

Design Change Notice 1644, Revision B, March 25, 1980 Sincerely, j

W W. F. Colbert Technical Director Enrico Fermi 2 hTC/MLB/dk Encls.

\\

D l

\\

8108210279 ggogg4

\\

l DR ADOCK 05000341 p

PDR.

-.. - ~ ~.

- - - - -