Text
.
0; l
CCDSum8lS i
Power James W Cook Oh Vice President - Prn4 cts, Engineering and Construction J
l General Offices: 1945 West Pernell Road, Jackson, MI 49201 * (517) 788-0453 August 10, 1981 b
N rd 1 e N
[6Y LQ L
Mr Harold R Denton, Director l
g Office of Nuclear Reactor Regulation i ~j AUC 17 gggj r US Nuclear Regulatory Commission Washington, DC 20555 g,s.ie,s** %
j MIDLAND PROJECT U
y DOCKET NOS 50-329, 50-330
/
PERMANENT PLANT DEWATERING FILE: 0485.16 UFI:
71*01, 00234(S) SERIAL:
13407
REFERENCES:
- 1) JWC00K LETTER TO HRDENTON SERIAL 12243, DATED JUNE 8, 1981
- 2) RLTEDESCO LETTER TO JWCOOK DATED JUNE 18, 1981 ENCLOSURE: FIGURE 1 LOCATION OF BACKUP INTERCEPTOR WELLS Our construction of the backup interceptor dewatering wells has progressed to a point which requires your concurrence on the final eight wells. As you recall, we deferred installation of these wells pending additional soil samples as requested in your June 18, 1981 letter.
We have completed drilling pilot holes at the location of relocated permanent Backup Wells F-1, F-5 and F-7 as well as at the locations of permanent Backup Wells G-7 and G-8 (Figure 1).
A sufficient thickness of sand was encountered at each location for well installation. The results of representative grain size analysis indicate the design gravel pack material is compatible with the material to be screened. Therefore, we request permission to proceed with the installation of the eight relocated permanent backup wells designated as G-9 l
and F-1 through F-7.
Wells Executive Manager For J W Cook JWC/RLT/ RAP /dsb l
oc0881-0394a100
[
8108190427 810810' PDR ADOCK 05000329 A
i PDR
2 CC Atomic Sately teu Licensing Ar 2a1 Board, w/o Atomic Safety and Licensing Board Panel, w/o CBechhoefer, Esq, w/o JEBrunner, Esq, w/o MMCherry, Esq, w/o RJCook, Midland Resident Inspector, w/o Dr FPCowan, w/o RSDecker, w/o SGadler, w/o DFJudd, B&W, w/o FJKelley, Esq, w/o RBlandsman, Region III, w/a WHMarshall,w/o HMiller, IL&B, w/o WDPaton, Esq, w/o HSingh, Army Corps of Engineers, w/a MSinclair, w/o BStamiris, w/o CRStephens, w/o Docketing and Service Section, w/a oc0881-0394a100
b l
5' f
7
??
~ %,
N
'VIQ
/
i f
4 c.'q 4
d C
q
/
p\\t 44 S
S\\
g
'k N(h -
fp N
's 4N N
N h
9 N
s s
[3 9g t
\\
\\~'
3 j
.g
[2' [f[^1 E'
\\
v N
'O.
wn g
=
\\
?
tn 4
k 1, Q,1 Lek' L[ T 60' Mk PN/LLS
_.. A 99 3
SERV 1
^
cy cyto,e.[
I CIRC.U L ATING WATE R PUMP J
\\
i
\\
.h t o c.
s gj%
,; INTAKE STRUCTURE ST R U CTU RE
(
1 4
N
/
.'//
a BECHTEL
,- \\
E XP L AN ATION ANN AnDOR
+
'\\
o pad'.-up WELL k MIDLAND POWER PLANT M
@ RW Mo'6 LOCATION OF y
g g nqt_ou nog BACKUP INTERCEPTOR WELLE
/
/ jfr f ' /
f fp
- k em.
_a m m u o.
an.
SCALE 1" = 50, P
7220 FIGURE iA
-L