ML20010B645

From kanterella
Jump to navigation Jump to search
Forwards LERs 81-029/03L-0 & 81-030/03L-0
Date released: 01/24/2020 Download: ML20010B645


LER 81-030/03L-0:on 810713,during Normal Operation,Steam Generator Stop Valve Dump Valve MRV-241 Removed from Svc. Caused by Seat Leakage.Valve Plug Machined & New Seat Ring Installed
ML20010B658
Person / Time
Site: Cook 
Issue date: 08/07/1981
From: Wizner D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010B658 (1)
LER 81-029/03L-0:on 810711,during Routine Tour,One Ice Condenser Intermediate Deck Door Found Partially Open.Caused by Ice Buildup.Ice Removed from Around Door & Door Returned to Svc
ML20010B649
Person / Time
Site: Cook 
Issue date: 08/07/1981
From: Wizner D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010B649 (1)
Forwards LERs 81-029/03L-0 & 81-030/03L-0
ML20010B644
Person / Time
Site: Cook 
Issue date: 08/07/1981
From: Shaller D
INDIANA MICHIGAN POWER CO. (FORMERLY INDIANA & MICHIG
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20010B644 (1)