AUG 4 1981 Docket lios: 50-329/330 R HORAhDull FOR:
Elinor G. Adensam, Acting Branch Chief Licensing Branch #4, DL FR0ft:
Darl S. Hood, Project Planager Licensing Branch #4, DL l
SUBJECT:
NOTICE OF PEETIliG NJD TOUR BY CASELOAD F0itECAST PNiEL TO ASSESS C0!JSTRUCTION C0fiPLETI0li SCHEDULES - MIDLAND PLNiT.
UtilTS 1 NiD 2 DATE & TIME:
August 25, 1981 (Site Tour) 8:30 a.m.
August 26-27, 1981 Mseting 8:30 a.m.
LOCATION:
August 25 (Plant tour): llidland Plant Site August 26-27, 1981 (Discu'sions): Consumers Service Center 1100 S. Washington Street tiidland, Itichigan PURPOSE:
August 2S: To tour and observe plant construction progress.
August 26-27: To discuss coupletion status and schedules for Hidland Plant Units 1 and 2 1/
PARTICIPANTS:~
NRC Consumers Power Company W. Lovelace J. Cook, et al J. Itatore D. Hood bechtel J. Rutgers, et al Darl S. Hood, Project flanager l
Licensing Branch (4 l
Division of Licensing cc: See next-page
-1/
~
The steeting of August 26-27 is open fur interested members of the public, ptitioners, intervenors, or other parties to attend as ooservers pursuant to j
,,,..m... ;, ouu
-.ci..cii s v i.uw noi r ro n cy, w reueral hug 1 ster 28668, t4on.Lfg4 g
6/28 For t;he. 5.1.t.e...tnur..on. Augu it. 25..1931,..permis si on..to..onter:.construc
"""siYe/78.idusf Ee",o,b tai ned in advance fram Consumers Power Company.'
'" *"" 'D omer)
.. - ~ ~
D. Hood:eb E.A nsam e y g g n g %.......
".2I'*L.$ff'-#.... ' *
--.....~.- -.
. ~~~
~ - -
'~-
ac n A OFFICIAL RECORD COPY 5 @" ** - '"
MILLAND Mr. J. W. Cook Vice President Consumers Power Conpany 1945 West Parnall Road Jackson, Michigan 49201 cc:
Michael I. Miller, Esq.
Mr. Don van Farrowe, Chief Ronald G. Zamarin, Esq.
Division of Radiological Health Alan S. Farnell, Esq.
Department
-# Publ'c Health Isham, Lincoln & Beale P.O. Box 33035 Suite 4200 Lansing, Michigan 48909 1 First National Plaza
- Chicago, Illinois 60603 William J. Scanlon, Esq.
2034 Pauline Boulevard Jares E. Brunner, Esq.
Ann Arbor, Michigan 48103 Consumers Power Cocpany 212 West Michigan Avenue '
U.S. Nuclear Regulatory Commission Jackson, Michigan 49201 Resident Inspectors Office Route 7 Myron M. Cherry, Esq.
Midland, Michigan 48640 1 IBM Plaza Chicago, Illinois 60611 Ms. Barbara Stamiris 3795 N. River Ms. Mary Sinclair Freeland, Michiga,n 48623 5711 Summerset Drive Midland, Michigan 48640 Stewart H. Freeman Assistant Attorney General State of Michigan Environmental Protection Division 720 Law Building Lansing, Michigan 48913 Mr. Wendell Marshall Route 10 i
Midland, Michigan 48640 Mr. Steva Gadler 2120 Carter Avenue St. Paul, Minnesota 55108 rww
4.
MIDIED PIAC WPIS NO 1_ A'ID NO 2 Caseload Torecast Panel Site Visit 1%eting frenda August 25-26, 1981 Overview of project constrt>: tion schedu.Le including progress and asjer 1.
milestones ccx:pleted since cascimd psnel visit of July 1980, currect prob 1c=s, bases for current dates and einy saticipated prt>blem areas that srAy impnet the current projected fac1 load date.
2.
Detailed review of project schedule identifying critical path itens, near critical ite=s, rc.eunt of flent for vnrious activities, the current critical Icth to fael loading, ratheds of ir-pler2ntation of corrective action for any activities vith negative float and provisions for contingencies.
Estiansted percent co=plete for (1) Unit No 2 and needed cerrwn facility, (2) Unit No 1 and (3) total project,all as of July 31,1981.
Detailed reviev and currect status a.ad forecast of design sad engineering 3
effort including any potential problems that r.sy arise fras necessary revert.
1 Detailed Meiev and current status of p-ocurcment activities including 4
valves, pipe, instr. rents, esble, major ecxq=ocents, etc.
\\
5.
Actual and proiosed craft work forec (by cajor craft), craft availability, productivity, Mential labor ocEctiations end problems.
6.
Detailed reviev end current status of all large and small bore pipe hangers, restraints, snubbers, etc. including decisn, revert, procurczent, fabrication, delivery and instnllr, tion, broken down far Unit No 2 and necied cosmon facilities and Unit No 1.
Iktailed review and current status of buie quantitie including current 7
total estir.ated qunctitics, q.mntities installed to dste, quantities scheduled to date, current percent ecuplete for each, actvl vs fo:tcast inst,allntion rates and bssis for these figures broken down separately 4
for (1) Unit go 2 vith needed ecxron facilities and (2) Unit No 1.
Concrete (CY - Cubic Yards) a.
b.
Process Pipe (IJ - Linear Feet)
- Inrge Barc Pipe (2-1/2" and Larger)
- th:11 B7re Pipe (2" and fr4ler) c.
Tarti Pipe (IJ)
Large Bore Pipe Bangers, Restrcints, S:mbbers Etc (Ench) d.
Sr.n11 Bore Pipe Henger, Restraints, F-c (I:nch) c.
f.
Cable Trny (IF)
m L-t o
2 Total Cm onit (LF) g.
h.
Total Erposed Metal Conduit (I7) 4
- i. Electric Cable (IX)
[
- Power
- Control
- Instrtraentation
- Plant Lighting
- Security J.
Klectrical Termineitions (Fach)
- Power
- Control
- Instruncatntion
- Plant Lighting
- Security h.
Electrical Circuits (Each) 1.
Instrumntation (Ihch)
Ccuparison of Forecast' Six Qasntities With Prcrious Forecasts m.
8.
Detailed review and current status of preoperation of preep test procedures, integration of preop test activities with constniction schedules.
rysterrs turnover schedule, preep test schedule, current and prgosed preop test progren manpower, broken down separately for (1) Unit 50 2 vith needed cccnon facilitics and (2) Unit No 1.
a.
Total Inmber of Procedures Required for Puel Load b.
Ember of Draft Procedures Not Started c.
Number of Drnrt Procedures Being Written d.
Wirzber of Procedures Approved
- e.
- Number of Procedures in Beview f.
Total Xtsaber of Preop Tests P.equired for Ptsel Icad g.
Hunber of Prcop Tests Cw.pleted h.
Nt:xber of Preop Tests Currently in Progress 1.
Number of Cyste=s Turned Drer to CP Co J.
Preop Tests Planned or in Progress for' Unit No 1 After Fuel Ioad of Unit No 2 9
Detailed discussion of patentini construction innuence due to changes attributed to fdPE.-(TTIf and other recent licensing requiresents.
10.
Discussion of nchedular ir.pnet, if eury, reganling potential deficiencies I
reported in accordance with.10 CFR 50.55(e).
t
- 11. Overview of carrent cesstruction canagt. tent organizr. tion and activities.
i'
- 12. Site tour nnd observation of construction activities.
- 13. Basis for cc:apletion date extencion.
IEB 8/3/81
s i
MEETING NOTICE DISTRIBUTION Dccket File to -d 27 J. Kramer NRC POR J. Stolz Local PDR S. Hanauer AUG 4 1981 TIC P. Collins NSIC D. Vassallo LB #4 r/f D. Ziemann N. Hughes T. Murley N
E. Case F. Schroeder 9
D. Eisenhut K. Kniel
/
F bl * ': ?
R. Purple D. Skovholt T. Novak G. Knighton g * *'y S. Varga M. Ernst T. Ippolito R. Baer 5 AUG 10 '331
- l' R. A. Clark E. Adensam F, p a uma R. Reid A. Thadani
\\
re*
- R. Tedesco ACRS (16)
/
A. Schwencer 0IE (3)
Y. /.9.. \\ jQ' '
J. Youngblood Attorney, OELD
/
5 F. Miraglia OSD (7)
J. R. Miller Project Manager D. Hood G. Lainas Licensing Assistant !!. Duncan D. Crutchfield Receptionist W. Russell TERA J. Olshinki J. LeDoux, I&E i
R. Vollmer V. Moore R. Bosnak I&E Headquarters F. Schauer I&E Region I R. E. Jackson I&E Region II 4
i G. Lear I&E Region III V. Noonan I&E Region IV S. Pawlicki I&E Region V V. Benaroya Z. Rosztoczy NRC
Participants:
U. Lovelace W. Haass J. "atore D. Muller D. Hood R. Ballard W. Regan R. Mattson P. Check Chief, Power Systems Branch
- 0. Parr F. Rosa bec: Applicant & Service List W. Butler W. Kreger R. W. Houston Chief, Radiological Assessment Branch W. Gammill L. Rubenstein i
T. Speis W. Johnston B. Grimes S. Schwartz F. Pagano S. Ramos
-,