Form NRC 618 U.S. NUCLE AR RECUL ATORY CoMMISSloN CERTIFICATE OF COMPLI ANCE

,g CFR 71 For Radioactive Materials Paestages 1 (s) Certificate Number 1,(b) Revision No.

1.(c) Packace identification No.

1.(d) Pages No. 1.(e) Tolpi No. Pages 5463 1

USA /5463/AF 1

.5

2. PRE AMBLE 2.(a)

This certiScate is issued to satisf y Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Har.ardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.lb)

The packaging and contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of F ederal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Condsteons.'

2.fc)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U S. Department of Transportation or other applicable regulatory agencies, including the governrnent of any country through or into which the package will be transported.

3 This cert Scate is issued on the basis of a safety analysis report of the package design or application-3.(a ). Prepared by (Name and add.ers);

3.(b)

Title and identification of report or application:

Urion Carbide Corporation Safety Analysis Report for Packaging (0ak Ridge L. clear Division Y-12 Plant Foamglas Shipping Package for Enriched 08k Ridge Y-12 Plant, P.O. Box Y Uranium) Report No. Y-DD-156, September 1974.

Oak Ridge, TN 37830 a tei Docket No. 71-5463 4.

Co** D IT IO N S This certificate is c >nditional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditeens specified in item 5 below.

! Description cf Fhc* aging and Authorized Contents, Mcds! Number, F:ssine Class, Other Conditions, and References.

(a)

Packaging (1) Model No.:

FD (2)

Description j

Packaging for uranium enriched in the U-235 isotope.

The containment vessel consists of DOT Spec 2A or 2N metal inner l

l container, 6-3/16 inches diameter by 8-3/4-iRches high.

The containment vessel is centered and supported within a 16-(

gage outer steel drum with a 14-gage head, DDT Spec 6J or equivalent, by solid foamed boron silicate glass.

The outer steel drum is 22-1/2 inches diameter by 22 inches high.

The outer steel drum closure must be at least a 12-gage bol ted ring with drop forged lugs, one of which is threaded, and having a 5/3-inch steel bolt and lock nut.

The package gross weight is 145 pounds.

(3)

Drawing l

<he packaging is as described and fabricated in accordance with Union Carbide Corporation, Nuclear Division, Y-12 Plant Drawing No. E T-55301.

l l

l 8108120300 810904 l

PDR ADOCK 07105463 l

C PDR

Page 2 - C rtificate No. 5463 - Revision No.1 - Docket No. 71-5463 5.

(b)

Contents (1) Type and, form of material Uranium metal, alloys or dry compounds, of any enrichment in the U-235 isotope.

(2) Maximum quantity of material per package not to exceed Type A quantities radioactive material and:

(i)

Not more than 3.7 kg of U-233, or (ii)

Not more than 19.0 kg of U-235 with the H/U ratio not more than 2, considering all sources of hydrogen within the inner containment vessel.

(c)

Fissile Class I, II and III (1)

Class I For the contents described in 5(b)(1) and limited in 5(b)(2)(i).

(2) Minimum transport For the contents described in index to be shown 5(b)(1) and limited in on label for 5(b)(2)(ii):

Class I-I 0.5 (3) Maximum number of For the contents described in packages per shipment 5(b)(1) and limited in for Class III 5(b)(2)(ii):

200 1

l 6.

The package authorized b/ this Certificate of Compliance 14 bereby approved for use under the the general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.

7.

Expiration date: July 31, 1986.

l l

l l

I Page 3 - Certificate No. 5463 - Revision No.1 - Docket No. 71-5463 i

j REFERENCE Safety Analysis Report for Packaging (Oak Ridge Y-12 Plant Shipping Package for Enriched Uranium)' Retort No. Y-DD-156, September 1974.

I FOR THE U.S. NUCLEAR REGULATORY t.CMMISSION

=Y Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and r

Material Safety AUG 0 41981 Date: _

N I

i I

f

}

I i

1 I

l 1

1 i

i l

r

..-.--.........,i_.._-,-...--,._,.._--__-..-.,-.--,-,--,.--,~,_,,,_---,._..

..,-_--_,,-r,._,,,,

,