ML20010A312

From kanterella
Jump to navigation Jump to search
Interim Significant Deficiency Rept 19,re Target Rock Motor Operated Valves - Bushing Not Staked,Initially Reported on 801215.Valve Mods Will Be Completed by 811215.Final Rept Will Be Submitted by 811231
ML20010A312
Person / Time
Site: Waterford 
Issue date: 07/31/1981
From: Aswell D
LOUISIANA POWER & LIGHT CO.
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, W3K-81-0278, W3K-81-278, NUDOCS 8108110304
Download: ML20010A312 (1)


Text

F Gmb g o. s ge3 15 H D is Nie co cay 1

L.OUISIANA P O W E R & L I G H T! P O BOX 6008

  • NEW ORLEANS. LOUISIANA 70174 242 Oct,RONOe smeer

. (504) 366 2345 EuI$SysYE July 31, 1981 o.L.aswtu Vee Presdent-Power Prtxkcton W3K-81-0278 Q-3-A35.07.19 Q-3-A35.02.01

/A l f S Mr. K. V. Seyfrit, Director, Region IV pd \\ '

~'/,'

U. S. Nuclear Regulatory Comutission d

Office of Inspection and Enforcement

(

x s

611 Ryan Plaza Drive, Suite 1000 h

h8 Y

Arlington, Texas 76012 7

Q l.

B' J

SUBJECT:

Waterford SES Unit No. 3 i^

c e Docket No. 50-382

/

D kK q,7

" Target Rock Motor Operated Valves - Bushing Not Stake)dQioM Significant Constlaction Deficiency Nc. 19 F,e f erence : LP&L Letter W3K-80-0013 dated December 15, 1980

Dear Mr. Seyfrit:

The interim report for Significant Construction Deficiency No. 19 was submitted to the NRC via above reference. In the report, we indicated that corrective action would be accomplished and a Final Report submitted by July 31, 1981.

We have been notified by Ebasco that the modification of the subject-valves is now scheduled to be completed by December 15, 1981.

Based on this information, the final report for Significant Construction Deficiency No. 19 will be submitted to the NRC by De : ember 31, 1981.

If you have any questions, please let us know.

Very truly yours, D. L. Aswell DLA/LLB/grf g)7 cc:

1) Director Office of Inspection & Enforcement 3

U. S. Nuclear Regulatory Commission Washington, D. C. 20555

/D

2) Director Office of Management Information and Program Control C. S. Nuclear Regulatory Commission Washington, D. C. 20555 8108110304 810731 PDR ADOCK 05000392 S

PDR