Revised LER 80-089/03X-1:on 801205,electric Driven Emergency Feedwater Pump Indicated No Flow or Discharge Pressure. Caused by Failed Pump Shaft,Due to Heat Stress Caused by Failure of Radial & Thrust Bearings