ML20010A103

From kanterella
Jump to navigation Jump to search
Forwards Revised LER 80-089/03X-1
Date released: 01/24/2020 Download: ML20010A103


Revised LER 80-089/03X-1:on 801205,electric Driven Emergency Feedwater Pump Indicated No Flow or Discharge Pressure. Caused by Failed Pump Shaft,Due to Heat Stress Caused by Failure of Radial & Thrust Bearings
ML20010A106
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 07/16/1981
From: Cogburn T
ARKANSAS POWER & LIGHT CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20010A106 (2)
Forwards Revised LER 80-089/03X-1
ML20010A102
Person / Time
Site: Arkansas Nuclear Entergy icon.png
Issue date: 07/16/1981
From: Trimble D
ARKANSAS POWER & LIGHT CO.
To: MADSEN G L
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
Download: ML20010A102 (1)