es.

v Form NRC418 U.S. NUCLE AR REGULATORY COMMISSloN CERTIFICATE OF COMPLI ANCE to CFR M For Radioactive Materials Packages 1.tal Certificate Number 1.(b) Revision No.

1.(c) Packace identi ication No.

1.(d Pages No. 1.(e) Total No Pages 6771 3

USA /6771/B(

i 2

2. PREAMBLE 2.(a)

This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Regulations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.

2.(b)

The packaging and contents described in item 5 below. meets the safety standards set forth in Subpart C of Title 10. Code of Federal Regulations, Part 71, " Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.

2.(c)

This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through cr into which the package will be transported.

3. This certificate is issued on the basi of a safety analysis report of the package design or application-3.(a)

Prepared by (Name ar.d address):

3.lb)

Title and identification of report or application:

Metropolitan Edison Company Metropatlitan Edison Company.

P.O. Box 480 application dated April 27-, 1981.

Middletown, PA 17057 7l~b77l 3.(c)

Docket No.

4 CONDITIONS This certificate is conditional upon the fulfilfing of the requirements of Subpart D of 10 CFR 71; as applicable, and the conditions specified in item 5 below.

5. Description of Packaging and Authorized Contents Model Number, Fissile Class, Other Conditions, and

References:

(a)

Packaging (1) Model No.: SN-1 (2)

Description A shipping container for radioactive waste.

The packaging consists of an outer container which is.a 4-inch thick right

~_

circular cylindrical steel shell.

The cylinder is 80 inches in diameter and 84 inches high with a welded bottom plate and a cover secured by 24,1-1/4-inch diameter steel bolts with a silicone rubber 0-ring.

Impact limiters consisting l

~

of shock absorbing foam clad in 24-gage stainless steel, are provided at the top and bottom of the container.

The remainder of the cask is surrounded by a one-inch layer of canned insulation. The maximum v.oight, including contents, is 60,000 pounds.

(3)

Drawings The packaging is constructed in accordance with SUNTAC Nuclear Corporation Drawing No. B-08001, Revision E; Wilson L

Manufacturing Company, Inc., Drawing No. 73-8333-B, Rev. A; and Rilco Manufacturing Company, Inc., Drawing No. 72-A-12a, Rev. O.

l-8108100462 810731 PDR ADOCK 07106771 l

C pg

~

L Page 2 - Certificate No. 6771 - Revision No. 3 - Docket No. 71-6771 5.

(b) Contents (1)' Type and form of material Greater than Type A quantities of nonfissile radioactive material as solidified or dewatered waste contained in leak tight secondary containers.

(2) Maximum quantity of material per package.

5,000 curies

[

6.

As required, shoring must be placed between the secondary container (s) and the cask cavity to limit movement during normal and accident conditions of transport.

I j

. 7.

Prior to each shipment, the packaging lid silicone rubber 0-ring must be inspected. The 0-ring must be replaced with a new silicone 0-ring if inspection shows any defects or every six (6) months, whichever occurs

. fi rs t.

8.

The package authorized by this certificate is bereby approved for use under the general license provisions of 10 CFR 571.12(b).

9.

Expiration date: July 31,.1986.

l REFERENCE Metropolitan Edison Company application dated April 27, 1981.

FOR THE U.S. NUCLEAR REGULATORY COMMISSION I'

~

Charles E. M Donald, Chief

~

i Transportation Certification Branch Division of Fuel Cycle and Material Safety, Date:

i 0

4

}

r

  • o'---'T e-9