ML20009H138

From kanterella
Jump to navigation Jump to search
Leak Testing Procedure for Radioactive Matls Contained in Special Form or DOT 2R Capsules
ML20009H138
Person / Time
Site: 07109851
Issue date: 02/12/1980
From:
ENERGY, DEPT. OF
To:
Shared Package
ML20009H136 List:
References
19398, 31, NUDOCS 8108060108
Download: ML20009H138 (3)


Text

.n OPERATIONS DIVISION PAM 1

)

g#

RADIOISOTOPE DEPARTMENT un 2112!so BUILDING 3029 SOURCE DEVELO?.".ENT LABORATORY LEAK TESTINO PROCEDURE FOR RADIOACTIVE liATERIAI.S CONTAINED IN SPECIAL FCD10R DOT 2R CAPSULES I.

Leak Testing A.

General All radioactive materials contained in Special Form or DOT 2R capsules are leak tested before shipment. The method used is f

the air bubble, vacuum, and glycol as descriDed in ANSI Standard l

N14.5 A3.6.

3.

Eouipment 1.

The leak test eouipment consists of a glass test cha=ber with a removable sealable top.

A line penetrates the top and is connected to an in-cell vacuum pump. The size and shape of the test chamber may vary with the design of the piece being tested; and cust be large enough that the piece can be

~

completely i==ersed in the test liquid, leaving at least one inch of test liquid above the weld atea.

2.

Racks, suspension assemblies, or si=ilar positioning devices

'may be required for some radioactive sources. These will be designed so as not to interfere with ebservation of the weld area during testing.

3.

Unless otherwise specified, the test liquid for liners is distilled water. The final test liquid for radioactive sources is ethylene glycol.

The' final leak test has a sensitivity greater than 1 x 10' at.cm /sec.

3 C.

Procedure f

I 1.

The test chamber is filled with test liquid to a depth g

sufficient to cover the piece being tested and leave at least one inch, but not more than three inches, of test liquid above the weld area when the piece is in the test position.

2.

The top is placed on the test cha:ber and a vacuum of at least 20 inches Hg is i= posed.

3.

The piece, and especially the veld area, is observed for 30 seconds while the vacuum is maintained. A leak is l

indicated by a steady stream of air bubbles coming from a fixed point on the source.

4.

After the 30-second observation the vacuu= is relieved;

{

then the piece is re=oved fro = the test chamber.

i f

(

. asa n o ve o

.4

[ -:,f.

Y #f #<:~'

9 /12/S0

/,...e.

(.#

JCm-t 2W a n B108060108 810714 PDR ADOCK 07109 C

~

GPERA TIONS DIVISION

~

RADIOISOTOPE DEPARTMENT e ',"

in2%0-BUILDING 3029 i

SOURCE DEVELOPMENT LABORATORY LEAK TESTINC PROCEDURE FOR RADICACTIVE MATERIALS CONTAINED IN SPECIAL FO'DI 0:t DDT 2R CAPSULES

(-

i a.

Leaking pieces are rejected and defueled.

s b.

Non-leaking pieces are transferred to the furnace testing area.

}

t i

4 i,

i I

t A"PR0vCO f> " E "*/15 3 P P R O C.C'j' G Ay 5'( g A of n /

QaTg e

v v

dl? }'O, /& C.r %- M o

~

E-2/12/80 UCes.e 2333 A (3 4 77*

m_.

OPERATIONS DIVIslON 31 a

2 ow a,

l' ADIOISOTOPE DEPARTMENT o n,'

, n,..n BUILDING 3029 SOURCE DEVELOPMENT IABOPATORY LEAK TESTING PROCEDURE FOR PADICACT:VE MATERIALS CONTAINED IN SPECIAL FORM OR DOT 2R CAPSULES RADIOACTIVE SOURCE DATA SilEET Customer Capsule No.

S.W. No.

Fuel Form Curies Fuel Batch No.

Assay I

Nom. Dim.-0.D.

I.D.

Length Cap. Thk.

Capsule Comp.

Spec. Sheet Accepted Reject l l

Date l

Supvr.

Capsule & Cap Degreased l

Liner No.

Liner Cleaned Liner Dried (

)

I Welding Procedure Test Weld No.

t Capsule Velded k

Co-tro-go Test l

Leak Test I

i Oven Test (

)

j Co-no-go Test I

. Leak Test Decontaminated Max.S= ear Avg.

k i

i l-Shelf Test Started l

Shelf Test Co=pleted l

Re-smear Max. Smear Avg.

l l

Co-no-go Test Source Disposition Apppovgo

  • "pf #y" ** Shj.

0'iJI2/3o U C w e 2513 A 83 a.7 7.

.