Significant Const Deficiency Rept 28 Re 2-inch & Below Schedule 160 Socket Welds Undersize.Repairs by Tompkins- Beckworth Scheduled for Completion by 810915.Final Rept Will Be Submitted by 810930
ML20009G432
Person / Time
Site: Waterford 
Issue date: 07/22/1981
From: Aswell D
LOUISIANA POWER & LIGHT CO.
To: Seyfrit K
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION IV)
References
10CFR-050.55E, 10CFR-50.55E, W3K-81-0265, W3K-81-265, NUDOCS 8108040252
Download: ML20009G432 (1)


Text

C O iIE

'{ 0, 3 3 f- >,

w 5

i1 Ie '

y J

l LoulSIANA

,42 mAnoNot s m POWER & LIGHT P O 80 *. 6006

'$u?OSysE u

D L ASV4LL July 22, 1981 v'c= P== dent-%er PnxWon W3K 0265 Q-3-A35.07.28 Q-3-A35.02.01 Mr. K. V. Seyfrit, Director, Region IV

/cQre,'/

U. S. Nuclear Regulatory Commission

,[y) '

Office of Inspection and Enforcement g

611 Ryan Plaza Drive, Suite 1000 g

g g'

Arlington, Texas 76012

-Q

SUBJECT:

Waterford SES Unit No. 3

_]_

g p,19 M " -

l g.co" 9g M 'u.5 Tb,s,5M

,J nocket No. 50-382 Significant Construction Deficiency No. 28 "Two-Inth and Below Schedule 160 Socket Weld dersize" CQ

Reference:

LP&L Letter W3K-81-0169 dated May 8, 1981 T[T

Dear Mr. Seyfrit:

The interim report for Significant Construction Deficiency No. 28 was submitted to the NRC via above reference.

In the report, we indicated that corrective action would be accomplished and a Final Report submitted by July 31, 1981.

We have been notified by Tompkins-Beckwith that the repair of the subject welds is now scheduled to be completed by September 15, 1981. Based on this information, the final report for Significant Construction Deficiency No. 28 will be submitted to the NRC by September 30, 1981.

If you have any questions, please let us know.

Very truly yours, D. L. Aswel1 DLA/LLB:grf p@7 cc:

1) Director Office of Inspection & Enforcement

/g U.

S. Nuclear Regulatory Commission Washington, D. C. 20555

2) Director of fice of Management Information and Program Control U. S. Nuclear Regulatory Commission Washington, D. C. 20555 8108040252 810722 PDR ADOCK 05000382 S

PDR