ML20009G235
| ML20009G235 | |
| Person / Time | |
|---|---|
| Issue date: | 07/21/1981 |
| From: | Papadopulos S, Perlman J NRC OFFICE OF ADMINISTRATION (ADM), S.S. PAPADOPULOS & ASSOCIATES |
| To: | |
| Shared Package | |
| ML20009G234 | List: |
| References | |
| CON-FIN-B-7343-1, CON-NRC-02-81-065, CON-NRC-2-81-65 NUDOCS 8108040007 | |
| Download: ML20009G235 (5) | |
Text
_ _,
x x,nsm sawCr5 AD=wsrt mN
. AW ARD/ CONTRACT l l5 FAGE CF ST AND ARD FORM 26, ' JULY 1966 f f D PeOC. Af c. MICFRI t-t hl0 B
- l. CONTRACT (l'ror. l rss.1/e:t./ NO.
2 Eff ECTlYE DA ft
- 3. REQUtilTION/PURCHA$t kOUEST/ PROJECT NO. _
- 4. CEpilflE3 FOR NATIONJ.L del (N$f UND(R SD$A NRC-02-81 -065 7/g/g//f RFPA NMS-81-065
'Jh2,^~"'o' "5 "L i-S. 155UE3 SY CODE
- 6. ADMINISTERED BY CODE l
- 7. DEllVERY FCS DtsTS.
(if esber than block $)
US Nuclear Regulatory Commission U N^=N Division of Contracts Ome. (w,
'd*->
Washington, DC 20555
.. CONTRACTOR code l l
racitirr code l
- 9. DISCOUNT 'ot raoar' '^rMzN' NA>AE AND ADDRES$
CS.S. Papadopulos & Associates
]
'ATT: Steven Larson-
','e." Ei'..
6218 Montrose Road
-s d m <adr> : Rockville, Maryland 20852
- 10. $USMit INvolCis (d repies unless esberwise purfed) TO ADDRESS SHOWN IN SLOCK f
II. 5HLP TO/ MARK FOR CODE (
l
- 12. PAYMENT WILL BE MADE BY CODE l US Nuclear Regulatory Commission US Nuclear Regulatory Commission ATT: Robert.Starmer.905SS Office of the Controller Program Support Br.-Office of NMSS Washington, DC 20555 l!ashington, DC 20555 O io us c rao < x i 13 THIS FROCUREMENT WAS O ADvrR'isrD.
~ico'IA'tD. 'AsuANr so b dl U.S.C. 252 (cM )
Id t.CCOJNitNG AND APPROPRaA710N DATA d & R No. 50-19-03-02 Fin No. B-7343 Appropriation Symbol: NA
$6440.00 33, t o.
I T.
18.
19.
20.
I tit M NO.
SUPPLit 5 / 5 E RvtCES Q U A NTITY UNIT UNIT PRICE AMOUNT 1
Training Course on Use of U.S. Geological Survej
, $'6440.00 Ground-Water Flow Models
~
u 8
bkkb bb 21.
TOTAL s.MOUMi OF CONTRACT $
CONTRACTING OFFICER lt'lLL CO.\\fPLETE BLOCK 22 OR 26 AS APP 11 CABLE 22.
CONTRACTOR'S NEGOTIATED AGREEMtut (Consrassor is required to sige
- 26. Q AWARD (Cee:racter is met required to sign sbis duus ent.)
Yo r ener 6 'oficitation Number lacteding the sh/s dermweif. sed return repies te issuing ejite.) Contractor agrees to fores! sad del.ver all items or perform oil the services set forth or otherwise additions or changes mode by yov which odddiene or changes are set forth in full Ident4.d obeve end on any cons.nvahon sheets for the cons.derot.on stated her**.
obove, is hereby occessed os to the items listed at,ove and on any conhnwation sheeth i
The e.gtes and obtegotions of the port.es to this contred shell be subject to and go*
This sword consummo'es the conteoct which consists of the followicg documentai (o) wneJ by the fellew ng documects: {o) this owned / contract,(b) the solicitation, if any, the Go.ornment's solicitotion and yona oPer, and (b) this o=ord/ contract. No and (c) s,ch prov s ets, repeesentetieas. certificoe.ons, and specifications, os are feether contractual document is necessary.
owecked or encorporated by reference herein.
(Attachaeonts are lhted hereie.)
,7. UNITED STA $ OF AMERICA (wufgm%
2
- 23. NAME OF CONTRACTOR S.S. Papadopulos & Assoc,iatesh,,,M is,no re.,,.rson o.thoringrygg g
(s.,nc re e, en,,oc,.n, 0%
11 NAMn n o mte or sooNet tr>pe er pri.r>) w l
2s: DAre sloNsD 2s. NAme OF ppN,nACvNo OmCet (r,pe., pri.r) 2,. DAry suoNw Stavros S. Papadopulos/
/
7/13/1981-V T
I a
_ _ __1
= 26-i0s 8108040007 810721 e-==~'~-==.--m.
PDR CONTR NRC-02-81-065 PDRc
e
- ~
NRC-02-81-065 p.~.,
Page 2 of 5' f
s
- ARTICLE I - SCOPE OF WORK:
'A.- The contractor shall furnish'the necessary, personnel,. facilities,
~~and materials ~to perform the following task:
The U S.G.S. finite-difference 2-Dimensional and 3-Dimensional Flow 1 g
- Programs (ref. (a)JFinite-Difference Model for Aquifer Simulation in Two Dimensions with Results of Numerical Experiments - U.S.G.S.
Techniques of Water-Resources Investigation, Book 7, Chapter. Cl; (b) Documentation'of Finite-Difference.Model'for Simulation of Three-Dimensional Ground-Water Flow - U.S.G.S. Open-File. Report 75-438 and Supplement to Open-File. Report 75-438) shall be pre-sented in a three-day course' designed and J ven by Mr. Steven P.
i Larson of the' contractors staff and approved by the NRC Project Officer.
The course shall cover the'following topics:
1.
Theoretical development; 2.
Practical considerations for application;
~ 3.
Limitations; 4.
Interpretation of output; 5.
Deck set up; and 6.
Simulation' examples, such that each participant can set-up and run one simulation for each of 2-D horizontal, 2-D vertical and 3-D cases.
The course shall be held at the NRC offices in Silver Spring, Maryland.
Approximately twelve (12) NRC personnel are expected to attend. An
- appropriate text book and/or notes shall be supplied by the contractor.
~
B.
Meetings:
The-contractor shall schedule seven trips to NRC in Silver Spring,
. Mary and as directed by the NRC Project Officer and will include a l
meeting before the course is presented to finalize plans and review s
.the proposed course materials.
All meetings shall be documented by the contractor and the documenta-tion transmitted to the NRC Project Officer within one week of said meeting. These trips are not expected to exceed one day in duration.
Meeting dates to be determined by NRC and contractor.
~
C.
Reporting Requirements:
The contractor shall supply NRC with a final report consisting of a
- complete set of all course materials; course outline, lecture notes, visual aidstused,.and example problems'with results. The contractor shall submit the course outline, course notes and problems in the
' form of a training manual.
a e
y y
y r
NRC-02-81 -065
' Page 3 of 5 A preliminary draft of the course materials shall. be submitted to the NRC for. approval by the Project-Officer at least one week prior to the first course session. This draft, after approval by the Project Officer, shall be1used for the course.. Participants in the course will provide comments on the course materials during the last-session of the course. -The final draft shall have been -revised to include comments from the Project Officer, and course participants, those comments to have ~ been submitted by.close of
- business on the' day after the last day of. instruction. The contractor shall
. submit the final report in. eleven copies (including one camera-ready copy) to:
4 US Nuclear Regulatory' Commission
.ATT: Robert Starmer.905SS Program. Support Branch Office of Nuclear Material Safety & Safeguards Washington, DC'20555 One copy of the final report shall be su$mitted to the following:
US Nuclear Regulatory Commission ATT: Ms. Joyce Perlman, Contracting Officer Small Purchases Section, ACB 286SS Division of Contracts Washington, DC 20555 US Nuclear Regulatory Comm:ssion --
ATT: Division of Technical Information i
and Document Control Washington DC'20555 US Nuclear Regulatory Commission ATT: ' John B. Martin, Director Division of Waste Management 905SS Washington, DC 20555 US Nuclear Regulatory Commission Office of Nuclear Material Safety & Safeguards ATT: Progrcm Support Branch 905S3 Washington, DC 20555 The above reports shall be submitted before the end of the six-week performance period.
l ARTICLE II - PERIOD OF PERFORMANCE i
Performance under this contract wili be for a period of six weeks from date of contract award at which time' all work shall have been completed.
, ARTICLE III - CONSIDERATION l
l In full consideration of the contractor's performance hereunder, the NRC shall pay the contractor a fixed-price of $6440.00.
l-ARTICLE IV - OBLIGATION The amount. presently obligated by the NRC with respect ta this contract is $6440.00.
l-i
.~
i W-
l
~
lNRC-02-81-065
.,o e ge.4 of 5 s
- r..
ARTf CLE V-PAYMENT I
Payaient shall be made in accordance with Clause 2 of the General Provisions-
, entitled " Payments" as -soon as practicable after completion and acceptance of. all of the work, upon submission by the Contractor of voucher (s) in a form
~
satisfactory to the Contracting 0fficer, provided, however, that said payment (s) shall not 'be deemed to ' prejudice any rights which the Government may have by law L
or under other_ provisions of this contract.
~
ARTICLE VI - PROJECT OFFICER Robert Starmer is hereby designated as the Contracting Officer's authorized representative (hereinafter called Project Officer)' for technical aspects of'
- this contract. ' The Project Officer is not-authorized to approve or reouest l
any action which results in or could result in an increase in contract cost; or termiaate, settle any claim or dispute arising under the contract; or issJe any unilateral directive whatever.
l The~ Project Officer is responsible for:
(1) monitoring the' Contractor's technical progress, including surveillance and assessment-of performance, and recomending
' to the Contracting Officer changes in requiresents; (2) interpreting the scope of work; (3) performing technical evaluation'as required; (4) performing technical inspections and acceptances required by this contract; and (5) assisting the
. Contractor in the resolution of technical. problems' encountered during performance.
Within the purview of this authority, the~ Project Office,r is authorized to review l
all costs requested for reimbursement by contractors and submit recc=endations-
- for approval, disapproval, or suspension for supplies / services required under this contract.
The Contracting Officar is responsible for directing or negotiating any changes in terms, conditions, or amounts cited in the contract.
For guidance from trie Project Officer to the Contractor to be valid, it must:
(1) be consistent with the description of work set forth in the contract; (2) not constitute new assignment of work or change to the expressed terms, conditions, l
or specifications incorporated into this contract; (3) not constitute a basis l
for an extension to the period of performance or contract delivery schedule; and, l
as stated above, (4) not constitute a basis for any increase in the contract cost.
I' I
If the contractor receives guidance from the Project Officer which the contractor l
feels is not valid under the criteria cited above, the contractor shall immediately notify the Project Ofncer.
If the Project Officer and the contractor are not able to resolve the questiens within five days, the contractor shall notify the Contracting O f fi cer.
ARTICLE VII - DISSEMINATION OF CONTRACT INFORMATION The contractor shall not publish, permit to be published, or-distribute for public consumption, a'ny information, oral or written, concerning the resulte.
or conclusions made pursuant to the performance of this contract without the' prior written consent of the Contracting Officer.
(Two copies of any material proposed to be published or distributed shall be submitted to the Contracting
' Of fi cer. )
i
)
k
^^ ~ '~ ^
,,- _~,. A_ _. m n.,
dh5-NRC-02-81 -065
-2 Page 5 of 5
. ARTICLE'VIII - SPECIAL PROVISIONS VIII.1 2 GOVERNMENT FURNISHED MATERIALS,
~1he NRC shall provide.a copy.of the D'ivision of ADP Support's Computer ^
User's Guide if needed by the contractor. The NRC shall. provide meeting
' facili. ties, audio-visual 1 equipment,- and computer facilities lat the discretion,of the NRC Project Officer.
VIII.2 KEY PERSONNEL LFor-the purpose'of Clause 26 of the General Provisions,- Steven P. Larson L
'is identified as being essential to the work being performed.
ARTICLE IX - GENERAL PROVISIONS The contract is subject to~the Fixed Price Research: and' Development Contracts Under $10,000.00,' dated November 14, 1977, which incorporates.the.FPR Changes and Additions and NRC Additions, attached hereto and made a part hereof.
l Clauseil4 entitled '" Patent Rights - Acquisition by the Government"-is deleted l
in its entirety.
l e
6 1
i J'-
s k
,;._,-..-.;,.-4,-_.,
w-___--
....