ML20009G142

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 81-028/01X-1
Date released: 01/23/2020 Download: ML20009G142


Updated LER 81-028/01X-1:on 810611,reactor High Pressure Switches Controlling RHR Shutdown Cooling Valves Found Above Allowable Limits.Caused by Setpoint Drift.Setpoint Reset & Surveillance Instruction Completed
ML20009G160
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 07/24/1981
From: Holder G
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009G160 (7)
Forwards Updated LER 81-028/01X-1
ML20009G141
Person / Time
Site: Browns Ferry Tennessee Valley Authority icon.png
Issue date: 07/24/1981
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009G141 (1)