ML20009F749

From kanterella
Jump to navigation Jump to search
Forwards Updated LER 81-058/03X-1
Date released: 01/23/2020 Download: ML20009F749


Updated LER 81-058/03X-1:on 810522,surveillance Testing of Steam Generator Level Channel Identified That lo-lo Level Bistable Setpoints for Reactor Trip & Safety Features Actuation Exceeded Limit.Caused by Failed Component
ML20009F752
Person / Time
Site: Sequoyah 
Issue date: 07/16/1981
From: Harding M, Wilkey A
TENNESSEE VALLEY AUTHORITY
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F752 (1)
Forwards Updated LER 81-058/03X-1
ML20009F748
Person / Time
Site: Sequoyah 
Issue date: 07/16/1981
From: Green H
TENNESSEE VALLEY AUTHORITY
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F748 (1)