ML20009F424

From kanterella
Jump to navigation Jump to search
Forwards LER 81-048/03L-0
Date released: 01/23/2020 Download: ML20009F424


LER 81-048/03L-0:on 810702,HPCI Isolated on High Steam Line Flow.Caused by Switch Failure Due to Loss of Internal Damping.Switch Replaced,Recalibr & Returned to Svc.Hpci Proven Operable
ML20009F429
Person / Time
Site: Hatch 
Issue date: 07/02/1981
From: Nix R
GEORGIA POWER CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F429 (2)
Forwards LER 81-048/03L-0
ML20009F423
Person / Time
Site: Hatch 
Issue date: 07/02/1981
From: Manry M
GEORGIA POWER CO.
To: OREILLY J P
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION II)
References
Download: ML20009F423 (1)