ML20009F366

From kanterella
Jump to navigation Jump to search
Order Prohibiting Use of Model NFS-4 Until Reasonable Determination Is Made by NRC That DOT Surface Contamination Levels Will Not Be Exceeded
ML20009F366
Person / Time
Site: 07106698
Issue date: 07/22/1981
From: Jennifer Davis
NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS)
To: Andognini G, Baynard P, Burstein S, Dawson D, Heider L, Lundvall A, Maiser J, Nardi A, Olsen A, Parker W, Seaman W, Shimshak R, Sullivan J, Toy H, Robert E. Uhrig, Wiedemann L
BABCOCK & WILCOX CO., BALTIMORE GAS & ELECTRIC CO., Battelle Memorial Institute, COLUMBUS LABORATORIES, BOSTON EDISON CO., COMMONWEALTH EDISON CO., DAIRYLAND POWER COOPERATIVE, DUKE POWER CO., FLORIDA POWER & LIGHT CO., FLORIDA POWER CORP., GENERAL ELECTRIC CO., JERSEY CENTRAL POWER & LIGHT CO., Maine Yankee, NUCLEAR FUEL SERVICES, INC., ROCHESTER GAS & ELECTRIC CORP., SOUTHERN CALIFORNIA EDISON CO., WESTINGHOUSE ELECTRIC COMPANY, DIV OF CBS CORP., WISCONSIN ELECTRIC POWER CO.
Shared Package
ML20009F361 List:
References
NUDOCS 8107310065
Download: ML20009F366 (4)


Text

.

O UNITED STATES OF AMERICA NUCLEAR REGULATORY COMMISSION In the Matter of

)

)

Docket No. 71-6698 NRC CERTIFICATE OF COMPLIANCE

)

N0. 6698 FOR RADI0 ACTIVE

)

MATERIALS PACKAGES

)

ORDER TO SHOW CAUSE (IMMEDIATELY EFFCCTIVE)

I On November 14, 1972, a Certificate of compliance under 10 CFR Part 71 was issued to Nuclear Fuel Services, Inc., for Model No. NFS-4 cask design.

The latest license expired on December 31, 1980, and is currently under timely renewal.

The packag',ng (" cask") identified as Serial No. NAC-lD is one of seven casks manufactured to the Model No. NFS-4 design.

All seven were suspended from service by the Commission's April 6,1979 Order concerning structural integrity.

On December 12, 1979, after further evaluation of the structural integrity, the Commission permitted three casks, including Cask Serial No. NAC-lD, to return to service with certain restrictions on their use.

II On at least seven occasions between August 1980 and July 1981, following offsite transportation, the cask displayed impermissably high levels of surface contamination under the Department of Transportation's regulations, 49 CFR 5173.397.

Fo' dowing the di?covery of the e. assive contaminations, the cask, before reshipment, was required to be decontamiritted to the levels perr,itted by 49 CFR 5173.397.

After transportation following the decontaminations, the cask repeatedly arrived with surface contamination exceeding the permissable limits of 22,000 dpm/100 cm2 by as much as 2,000,000 dpm/100 cm.

The increase in surface contamination exhibited 2

following transport suggests that contamination which originally was fixed, was released in transit.

The reason for this excessive contamination, which may be related to the surface finish of the cask, is not fully understood. There appears to be no reasonable absurance that future shipments of the cask would be within the surface contamination limits set forth in 49 CFR 5173.397.

8107310065 810727 PDR ADOCK 07106698 C

PDR

III In view of the repeated instances of excessive surface contamination, in violation of 49 CFR sl73.397, reasonable assurance does not now exist that the publi, health and safety will not be jeopardized by the continued use of this c sk. Therefore, I find that the public health, safaty and interest req; ire immediate suspension of use of cask Model No. NFS-4, Serial No. F 4C-10.

IV In view of the foregoing and pursuant to Sections 57, 62, 81, and 161(b) of the Atomic Energy Act of 1954, as amended, and the Commission's regulation in 10 CFR Parts 2 and 71, IT IS HEREBY ORDERED THAT:

(A) Use of the cask designated as Model No. NFS-4, Serial No. NAC-lD, outside the confines of a licensed facility or plant is suspended, effective immediately; provided that, for the sole purpose of attempting to requalify the cask for use outside the confines of a licensed facility or plant, it may be transported (empty) once to an appropriate testing / rehabilitation site, subject to the following procedures:

(1) Prior to shipment, surface contamination of the cask shall not exceed the levels permitted by 49 CFR 5173.397.

(2) The cask shall be packaged in plastic bagging covering the entire external surface of the cask except-the trunnions, which shall be covered with tape.

The bagging shall be secured with tape and banding.

(3) A health physics technician carrying monitoring instruments and extra tape, shall accompany the

shipment, (4) The integrity of the bagging shall be verified
t -

at transport intervals of not more than 80 miles.

(B) The owner / user show cause, as specified in Section V of this Order, why the suspension of the general license should not be continued until the Director, Office of Nuclear Material Safety and Safeguards, finds there is reasonable assurance that surface contamination levels will not exceed the require-ments of 49 CFR 5173.397 at any point during future shipments of the cask.

+

-. _ ~

O In determining >:hett'er there is reasonable assurance thet the cask will not expe.tence excessive contamination levels in transport, the Director will consider among other things:

(1) The extent of the understanding of the cause c# the excessive surface contamination (e.g., improper decontam-ination of cask surfaces and condition of cask surfaces).

(2) The action taken to refurbish the cask surfaces and/or decontamination procedurcs to be used compatible with user waste treatment facilities.

(3) Tests performed which simulate transport conditions to demonstrate the response to Items (1) and (2) above are correct and that excessive contamination levels will not be experienced.

V An owner / user to whom this order applies may show cause within 25 days of the date of this Order by filing a written answer under oath or affirmation which sets forth the matters of fact and law on which the licensee relies.

The owner / user may answer, as provided in 10 CFR 52.202(d),

by consenting to the entry of an order in substantially the form proposed in this Order to Show Cause.

Upon failure of the owner / user to file an answer within the specified time, the Director, Office of Nuclear Material Safety and Safeguards, may issue without further notice an order ~ continuing the suspension as described in Section IV above.

VI The owner / user or any other person who has an interest affected by this order may request a hearing within 25 days of the date of this Order.

Any answer 17 this Order or any request for hearing shall be filed with Mr. John G. Davis, Director, Office of Nuclear Material Safety and Safeguards, U.S. Nuclear Regulatory Commissien, Washington, DC 20555.

Copies shall also be sent to the Secretary of the Commission and the "t- -

Executive Legal Director at the same address.

If a person other than the owner / user requests a hearing, that person shall describe specifically, in accordance with 10 CFR 52.714(a)(2), the nature of the person's interest and the manner in which that interest is affected by this Order. ANY REQUEST FOR A HEARING SHALL NOT STAY THE IMMEDIATE EFFECTIVENESS OF SECTION IV (A) 0F THIS ORDER.

  • ?

.),

VII If a hearing is requested, the Commission will issue an Order designating the time and place of any hearing.

If a hearing is held, the issue to be considered at any such hearing shall be whether this Order should be sustained.

FOR THE NUCLEAR REGULATORY COMMISSION W

Jo n G. Davis, Director Office of Nuclear Material Safety and Safeguards Dated at Bethesda, Maryland this J.2. day of July 1981.