ML20009D519

From kanterella
Jump to navigation Jump to search
Forwards LER 81-050/03L-0
Date released: 01/23/2020 Download: ML20009D519


LER 81-050/03L-0:on 810613,RCS Gross Leakage Was Found to Be 16 Gpm.Caused by Natural End of Life of Root Valve Packing.Leakoff Line Capped,Reducing Leakage.Valve Will Be Repaired During Next Outage
ML20009D526
Person / Time
Site: Calvert Cliffs 
Issue date: 07/13/1981
From: Rayburn C, Wenderlich R
BALTIMORE GAS & ELECTRIC CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20009D526 (1)
Forwards LER 81-050/03L-0
ML20009D518
Person / Time
Site: Calvert Cliffs 
Issue date: 07/13/1981
From: Russell L
BALTIMORE GAS & ELECTRIC CO.
To: GRIER B H
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I)
References
Download: ML20009D518 (1)