Form DOE-618 U.S. DEPARTMENT OF ENERGY jlg4 CERTIFICATE OF COMPT. LANCE ERDAM 5201 Ic. Certificate Nurreer 1b. Rowisson No.
I tc. Pacmage toentsfecation No, 1 Id. Page No.
le. Total No. Pages.
nu/coca/m (nor inh 1
- 2. PREAMBLE 2a.
This certificate es issued to satisfy Sections 173.393a 173.394,173.395, and 173.396 of the Deoertment of Transoortation Hazardous Meteriais Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Decertment of Transoortatica Dangerous Cargoes Regulatens (46 CF R 146-149), as amenced.
2b.
The poemaging and contents described in item 5 Detow, meets the safety standards set forth in Sucourt C of Title 10, Code of Federal Regulations Part 71," Packaging of Radacective Meterief for Transcort and Transportation of Radioactive Matertal Uncer Cartain Condit:ons."
2c.
TNs certifiste does not relieve the consagnor from como4sance with any requirement of the requestions of the U.S. Department of Transportation or other acoticenes regulatory agencies, including tne government of any country tnrougn or into wnsen it's package will be traceported.
- 3. This certifiate es issued on the besas of a safety enssynas report of tfie package cessgn or aposication-.
$p8t t'"fCNY " SaEy"An'Y1yT1$
Report for Packaging - Krypton Shipping $n 1975 En.i Nuclear Idaho t,umpany, Inc.
Container - USA /5958/BL(D0f-ID), by C. W. Nielsen.
P.O. Box 2800
~
Report ENIC0-1069, Addendum to ICP-1077 Idaho Falls, Idaho 83401 SARP for USA /5958/SL(DOE-ID), January 1981
- 4. coNDtTioNS Th,s artificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CF R 71. as aoolicabie, and the conditions spec:fied in item 5 eetow.
- 5. Description of Pecnagang and Authorized Contents, Modet Numoor, Fssaie C: ass, other Conditions, and Rererenas:
5.a.
Description of Packaging (common name - Krypton Shipping Container)
(1)
Outer Packaging (thermal shield)
( a)
End-loading cylindrical thermal shield consisting of concentric inner and outer steel walls (16 gage c.h) 6" apart, filled with high-temperature resistant (to 2,200 ) phenolic foam plastic and longitudinal oak stringers at 9 intervals.
(b)
Closed by 1/2" steel plate bolted to flanged inner steel wall with six 1/2" bolts. Outer cover (phenolic foam filled to 5-3/8")
attached with six 3/4" bolts torqued to 30 ft. lbs.
(c)
Exterior dimensions:
Thermal shield 83-1/2" long, 30" diameter, with metal framework (2" schedule 40 pipe) which measures 69-3/4" long and 30-1/4" wide.
Framework used for lifting and tie-down purposes.
(d)
Metal identification plate with container nomenclature, serial number, quantity of radioactivity. and name and address of owner.
(2)
Inner Packaging
( a)
Radiation Shield Container I.
End-loading cylindrical steel-encases (1/4") lead (2" thick) shield with 3 steel-encased plugs for loading, valve access, and access to gas cylinder retaining steel band.
2.
Closure by retention of end shielding plug with clamp (11" x 4-1/2")
held in place by two 5/8" set screws.
Shield cask cap (3/4" thick) se. cate of issuance:
April 1981 l Eb. Emo> ration Cate:
None FOR THE U.S. OEPARTMENT OF ENERGY 7a. Accress (of 00E Issuing Office) j 7b.c n ture, Nam ', and Title (of COE U. S. Department of Energy
(
Aca a f f,. roving Official) 550 Second Street
(.
p" "^
O Idaho Falls, Idaho 83401 Char 1es E. Williams "9
8107230272 810527 PDR ADOCK 071*****
C;.
(!MR
measuring 14" diameter is held in place by "V" ri'ng (clamped with two 5/16" bolts).
(b)
Gas Cylinder Primary containment by DOT Specification 3A or 3AA gas cylinder (length 52" and outside diameter of 9") rated to 2015 psig.
Cylinders to be certified at least once every 5 years by testing to 3360 psig.
(c)
Closure Valves 1.
Kerotest Valve - special high temperature monel valve (#440 x 70),
Kerotest Mfg. Corporation, 2525 Liberty Avenue, Pittsburgh, PA.,
15222. Valve measures 4-5/8" with a torque of 90 in. lbs. for closure.
2.
NUPRO Bellows Valve - special high temperature valve (series T),
NUPRO Co., 4800 East 345 St., Willoughby, Ohio, 44090. Valve measures 4" with a minimum torque of 50 in, lbs.
(increased torque may be required to assure leak tightness).
(3)
Gross Weight: 5200 lbs.
5.b. Authorized Contents Gaseous krypton-85 (Transport Group III) in large quantities, not to exceed:
(1) 74,000 curies (2) 1000 BTU /hr decay heat (293 watts)
(3) 500 psig gas cylinder pressure.
5.c. Leak Testing (1)
Each packaging, before first use; and siter every third use, or within the 12 months preceding any use, whichever comes first, shall be leak tested using a method capable of demonstrating that the maximum gas le k containment vessel and closure valve is less than 1 x 10~f age raj/sec.e from the primac atm-cm (2)
Prior to shipping, the primary containment vessel and closure valve shall be leak tested using a method capable of demonstrating that the maximun krypton-85 gas leakage rate from the vessel and valve is less than 0.278 uCi/sec. under "as-loaded" conditions.
5.d.
References (1)
A. J. Mallett and S. G. W1eatley, Fissile Material Container and Packaging Development and Testing Program, K-1686 Union Carbide Corporation, April 1, 1966.
(2)
A. J. Mallett and C. E. Newton, Protective Shipping Packages for 30-Inch Diameter US, Cylinders, K-1686, Union Carbide Corporation, AEC-ORGDP, April 13, 1967.
(3) 49 CFR, Parts 170-189, DOT Hazardous Materials Regulations.
(4)
ANSI Standard N14.5, American National Standard for Leakage Tests on Packages for Shipment of Radioactive Materials, dated October 1977.
1 9 ~' m -
a