ML20009C808
| ML20009C808 | |
| Person / Time | |
|---|---|
| Site: | 07109088 |
| Issue date: | 07/17/1981 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML20009C804 | List: |
| References | |
| NUDOCS 8107210559 | |
| Download: ML20009C808 (2) | |
Text
r-j'.
_m-
- .I Form NRC418 U.S. NUCLEAR REGULATORY COMMISSloN' 10 c R 71 CERTIFICATE OF COMPLIANCE For Radioactive Materials Packages
' 1.L) Certificate Nu
.1.(b) Revision No.
nt ication No.
1.(
Pages No. 1.(
Total No. Pages g
- 2. PREAMBLE 2.la). This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardous Materials Reputations (49 CFR 170189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.(b) - _ Tt e packaging and contents described in item S below, meets the safety stendards set forth in Subpart C of Title 10 Code of Federal Regulations, Part 71. ** Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions."
2.(c)
This certificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, in:luding the government of any country through or into which the package will be transported.
- 3. This certificate 3s issued on the basis tsf a safety analysis report of the package design or application-3.(a)
Prepared by (Name and address):
3.(b)
Title and identification of report or application:
Schlumberger Well Services Schlumberger Well Services Application P. O. Box 2175 dated May 15, 1981.
l Houston, TX 77001 3.!c)
Docket No..
- 4. CONDIflONS This certificate is conditional upon the fulfilling of the requirements of Subpart D of 10 CFR 71, as applicab and the conditions specified in item 5 below.
- 5. Des:ription of Packaging and Authorized Contents, Model Number, Fissile Class, Other Conditions, and
References:
(a)
Packaging (1) Model Nos.:
NLS-RF, NLS-KL, and NLS LM (2)
Description Tne containers are mild steel, welded, cylindrical shell with a full length stainless steel center tube containing a special-form capsules.
The 20.5-inch long by 17.3-inch diameter outer cylinder has a 0.075-inch thick shell and 1/8-inch thick end plates.
The annulus between the.
outer cylinder and the 2-inch OD by 1.73-inch ID center tube is filled with polyethylene for shielding.
The center tube bottom closure is a welded,-solid plug drilled for a bolt closure.
The upper closure is a removable steel plug engaged by a scissor tr chanism pad-locked closed.
Handling rings are welded onto both ends.
The gross weight of the contair,ers are 155 pounds.
-(3)
Drawings The packagings are constructed according to Schlumberger Well Services Drawing Nos. H-251810, Rev. 0; H-251507, Rev. 0; and Model No.
Source Ass'y Pressure Vr psel NLS-RF H-142108, Rev. C H-208167, key. 8 NLS-KL H-239681, Rev. A H-329044. Rev. 0 NLS-LM H-245258, Rev B H-329042, Rev. 0 h g K 07209ogg 59 sto737 i
C PCR
. _. -.. _ ~ ~ -,. _ _
.v,;
- Pag 12 - Certificate No. 9088 - Revision No.1 - Docket No. 71-9088
-5;
- (b) Contents ~-
-(1) Type.and' form Americium-241 as a' sealed source thet meets-the requirements of special form as defined in 10 CFR 571.4(o).
(2) Maximum quantity of material per package
~
'25 curies 6.-
-Name' plates shall be fabricated of materials capable of resisting the fire te.st of 10 CFR Part 71 and maintaining their legibility.
'7.
- The packagings authorized by this certificate are hereby approved for use
- under the general license provisions of 10 CFR 571.12(b).
8.
Expiration date: May 31, 1983, REFERENCE Schlumberger Well Services application dated.May 35, 1981.
l FOR.THE U.S. NUCLEAR REGULATORY COMMISSION
&5 Charles E. MacDonald, Chief Transportation' Certification Branch Division of Fuel Cycle and Material Safety Date: JUL 17 198I t-F g
r,-~,-,
--., - -, _,.- -