4 Gentlemen:
- 'IM '
This refers to your application dated February 16,1981, as amended, requesting additional contents in the Model No. NL-1/2 packaging.
In connection with our review,'we need the information identified in the enclosure to this letter.
Please advise us within thirty (30) days from the date of this letter
. when this infomation will be provided. The additional informatica mquested by this letter should be submitted in the form of revised pages to the safety analysis. If you have any questions regarding this matter, we would be pleased to meet with you and your staff.
f Sincerely, Original Signed by N E.MACDONALD.
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety, NMSS
Enclosure:
As stated i
l Distribution w/ encl:
WHLake
'~
CRChappell I
RH0degaarden #
Doc.ket Files i
M55 R/t FCTC R/F GJackson ZMcDonald i
c "q
l NRC PDR L
I
. g,,
g,
![Ci TC F
,,,,gg,,,,,
oma>
,,,,,,,p pe 1,1
, h,,W
,1,Qa e,,,,,,C,F.M</cDo,nal,d,,
- Su= W 8?aardep,:,a1 mC a
ammi 07/f/81 07//3/81,
07/15/81 07//f/81
" " " rl " " "
1.. sto721o477 810715 E JDR ADOCK 07109O %
, )FFICI A_L RECORD _ COPY _ _,,, _ _. _ _. _.. _
...--..U rg
i s
Model No. NL-1/2 Packaging Docket No. 71-9010 JUL 1 ~ 1981 Encl to ltr dtd:
1.
The application does not adequately show that the proposed canister meets the requirements of 10 CFR 171.42.
In.particular, the design of the proposed canister was not shown to t,e sufficiently similar
~
to the canisters ~ tested in 1975 and 1977 to support a conclusion that the performance of the proposed caniste would be similar to the performance of the tested canisters.
1dition, the application does not adequately describe the 1975 an: I ?/ :anisters, the tests to which they were subjected, or the resu, 5 th t were observed following the tests to support a conclusion 't the tested canisters would have mot the requirements of " CFR 571.42.
.2.
Provide. engineering drawings of the upper and lower spacers
'(i.e., Figure 6) that will be used with the canisters.
3.
Provide a copy of Reference (9) and show that the equation for mean crushing strength (pg. III-B16) is applicable to the post-buckling behavior of circular columns with no lateral support.
4.
Specify the maximum total weight of materials (contents, canisters and other objects) that are to be transported within the containment vessel of the cask.
Evaluate the closure of the cask containment vessel under 30-foot drop conditions (top end and top corner) considering the maximum total weight of material within the vessel.
5.
Appenddx C to Section III, which addresses containment for'the vitrified waste was not included in your June 15,.1981, submittal.
l l