Forwards LER 81-012/03L-0
Date released: 01/23/2020 Download: ML20009B601


LER 81-012/03L-0:on 810518,during Surveillance Testing,Valve MO-2-1001-7B Failed to Reopen.Caused by Failure of Auxiliary Contacts in Circuit Breakers to Disengage.Valve Manually Opened & Contacts Replaced
ML20009B603
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 06/10/1981
From: Kopacz J
COMMONWEALTH EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20009B603 (2)
Forwards LER 81-012/03L-0
ML20009B600
Person / Time
Site: Quad Cities Constellation icon.png
Issue date: 06/10/1981
From: Kalivianakis N
COMMONWEALTH EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20009B600 (1)