Docket No. 50-344 r
- Ell Port landGeneralElectricCompany Brt D mem 'ke Premmt t.(
I i
)
[
June 29, 1981
~
4 "j
k Trojan Nuclear Plant e
Docket 50-344 9
4 License NPF-1 d' gh Mr. R. H. Engelken, Director N
U. S. Nuclear Regulatory Commission Region V yh l
kh' 2,
Walnut Creek Plaza, Suite 202 N
1990 N. California Blvd.
S' Walnut Creek, CA 94596
,, _ ' M l 3198l g I
Dear Mr. Engelken:
\\h 9
examination of Containment penetration welds at the Trojan'hu6 d&q'y IE Bulletin 80-08 requested information regarding the nondest,ruc t
ant.
The PGE to NRC responses dated July 2, 1980 and August 25, 1980 stated that although all of the welds were examined by radiography, documentation records could not be located for some of the penetration welds. All of the Trojan Nuclear Plant penetration weld radiographs have now been located.
Table 1 of PGE's letter dated July 2,1980 has been editorially corrected and updated accordingly (see attachment).
No other changes are necessary.
This action concludes PGE's response to IE Bulletin 80-08.
Sincerely, gs u
Bart D. Withers Vice President Nuclear Attachment c:
Mr. Lynn Frank, Director State of Oregon Department of Energy
[
6i g
8107140763 810629 DRADOCK05000g 121 SW Sa! mon Street, Podand. Oregon 97204 J
2
-a
' Trojan Nuclear Plant License NPF-1 1;ocket 50-344 June 23, 1981 Sheet 1 of 4 TABLE I IE Bulletin 80-08 TROJ AN NUCLEAR PLANT CONTAINMENT PIPE PENETRATION P;netration Line Number Pipe Backing Number and Size Material Bars Used Repair Work Done 1)
P-1-1 3/4"-CCB-1 A-376/TY304 YES NO 2)
P-2-1 2"-CS-601R-4 A-312/TY304 YES Yes a) Slag Inclusion 3)
P-3-3 2"-CS-2501R-28 A-376/TY304 YES Yes a) Slag Inclusion 4)
P-5-2 2"-CS-2501R-28 A-376/TY304 YES NO
- 5) P-7 4"-CS-151R-6 A-312/TY304 N0 NO
- 6) P-8 3"-CS-2501R-5 A-376/TY304 NO NO
- 7) P-9 14"-RH-601R-5 A-358/TY304 NO Yes a) Incomplete fusion
- 8) P-10 4" DC-151R-1 A-312/TY304 NO NO
- 9) P-11 12"-RH-2501R-19 A-376/TY316 NO NO
- 10) P-12 3/4"-RC-2501R-21 A-376/TY304 NO NO
~
- 11) F -13 3"-HCB-16 A-312/TY304 YES NO
- 12) P-11-1 3/4"-HCB-17 A-312/TY304 YES NO
- 13) P 1. 7 3"-HCB-4 A-312/TY304 YES NO
- 14) P-20 3"-RC-151R-19 A-312/TY304 YES N0
- 15) P-21 3"-HBE-9 A-333 Gr6 YES Yes a) Slag Inclusion b) Root Concavity
- 16) P-22 3"-HBE-8 A-333 Gr 6 YES NO
- 17) P-40-2 3/4"-RC-151R-32 A-312/TY304 YES NO 18)
P-1-3 3/8"-RC-2505R-1 A-269/TY316 N0 NO
- 19) P-25 8"-HCB-11 A-312/TY304 YES NO
- 20) P-26 10"-HCB-10 A-312/TY304 NO NO
- 21) P-40-3 3/4"-SI-2501R-22 A-376/TY304 YES NO J
/
I
- Trojan Nuclear Plant License HPF-1 Docket 50-344 Sheet 2 of 4 TABLE I Penetration Line Number Pipe Backing Number and Size Material Bars Used Repair Work Done
- 22) P-28 14"-EBE-3 OUT A-106B INL A-353 Gr6 NO NO
- 23) P-29 14"-EBE-3 OUT A-106B INL A-333 Gr6 NO NO 24 ) P-30 14"-EBE-3 OUT A-106B INL A-333 Gr6 NO NO
- 25) P-31 14"-EBE-3 OUT A-106B INL A-333 Grf NO NO
- 26) P-32 28"-EBB-1 A-155 Gr KCF-70 NO NO
- 27) P-33 28"-EBB-1 A-155 Gr KCF-70 NO N0
- 28) P-34 28"-EBB-1 A-155 Gr KCF-70 NO NO
- 29) 9-35 28"-EBB-1 A-155 Gr KCF-70 NO N0 301 P-36-1 2"-EBE-6 A-335 Gr N0 N0
- 31) P-37-1 2"-EBE-6 A-335 Gr6 NO N0
- 32) P-38-1 2"-EBE-6 A-335 Gr6 NO N0
- 33) P-39-1 2"-EBE-6 A-335 Gr6 N0 N0
- 34) P-40-1 1"-SI-602N-1 A-106B YES NO
- 35) P-14-2 3/4"-GCB-10 A-312/TY304 YES N0
- 35) P-42 14"-HBE-2 A-333 Gr6 NO Yes a) Surface Defect
- 37) P-43 14"-HBE-3 A-333 Gr6 NO Yes a) Root Concavity
- 38) P-44 3"-SI-2501R-3 A-376/TY304 N0 N0
- 39) P-45 4"-SI-2501R-1 A-376/TY304 YES N0
- 40) P-46 8"-SI-2501R-31 A-376/TY304 YES N0
- 41) P-47 8"-SI-2501R-31 A-376/TY304 YES Yes a) Hole in backing ring
- 42) P-48 10"-HCB-9 A-358/TY304 YES N0 J
I
' Trojan Nuclear Plant License NPF-1 Docket 50-344 Sheet 3 of 4 TABLE I Penetration Line Number Pipe Backing Number and Size Material Bars Used Repair Work Done
- 43) P-49 10"-HCB-9 A-358/TY304 N0 N0
- 44) P-50 18"-GCB-5 A-358/TY304 N0 Yes a) Slag Inclusion
- 45) P-51 18"-GCB-5 A-358/TY304 YES N0
- 46) P-16-3 3/4"-CCB-1 A-376/TY304 YES N0
- 47) P-14-3 3/4"-CCB-1 A-376/TY304 YES N0
- 48) P-54 3"-HCB-15 A-312/TY304 NO Yes a) Slag inclusion b) Incomplete fusion
- 49) P-55 3"-HCB-12 A-312/TY304 NO NO
- 50) P-56-1 1"-HCC-19 A-312/TY304 YES NO
- 51) P-57-1 4"-HBE-11 A-333 Gr6 YES N0
- 52) P-58 3"-HCB-3 A-312/TY304 YES Yes a) Slag inclusion
- 53) P-62 1"-HCB-20 A-312/TY304 YES ND
- 54) P-63 4"-SI-2501R-1 A-376/TY304 NO N0
- 55) a -6 5 1"-HCB-20 A-312/TY304 YES N0
- 56) P-68 8"-HBE-14 A-333 Gr6 NO NO
- 57) P-69 1"-HCB-20 A-312/TY304 YES N0
- 58) P-70 4"-SI-2501R-1 A-376/TY304 NO N0
- 59) P-71 1"-HCB-20 A-312/TY304 YES NO
- 60) P-72 8"-HBE-14 A-333 Gr6 NO NO
- 61) P-74 14"-HBE-7 A-333 Gr6 NO Yes a) Root Concavity
- 62) P-76 14"-HBE-5 A-333 Gr6 NO Yes a) Root Concavity
- 63) P-101-1 8"-HBE-16 A-333 Gr6 YES Yes a) Slag inclusion
- 64) V-18 54 "-HB E-15 A-333 Gr6 NO Yes a) Slag inclusion b) Porosity
- 65) V-19 54"-HBE-15 A-333 Gr6 N0 Yes a) Slag inclusion b) Incomplete fusion
)
~
' T'rojan Nuclear Plant License NPF-1 Docket 50-344 Sheet 4 of 4 TABLE I Panetration Line Number Pipe Backing Number and Size Material Bars Used Repair Work Oone
- 66) P-3-2 2"-CS-2501R-28 A-376/TY304 YES Yes a) Slag inclusion 67)
P-5-3 2"-CS-2501R-28 A-376/TY304 YES N0 68)
P-5-1 1"-GBB-1 A-333 Gr6 YES NO
- 69) P-36-2 3/4"-EBE-6 A-333 Gr6 NO NO
- 70) P-37-2 3/4"-EBE-6 A-333 Gr6 NO NO
- 71) P-38-2 3/4"-EBE-6 A-333 Gr6 N0 NO
- 72) P-39-2 3/4"-EBE-6 A-333 Gr6 N0 N0 1
- 73) P-37-3 2"-HBE-17 A-333 Gr6 NO N0
- 74) P-39-3 2"-HBE-17 A-333 Gr6 YES NO
- 75) P-101-2 8"-HBE-16 A-333 Gr6 YES Yes a) Slag inclusion
- 76) P-57-2 4"-JBD-35 A-333 Gr 6 NO N0
- 77) P-56-2 1"-HCB-19 A-312/TY304 YES NO A0W/vrb 3-55.7A19 r.
'