l' i

JUL 3W Joint llospital Services, Inc.

License No.34-176'.6-01 ATTN:

Mr. Robert. D. Severn Chairman Administrative Committee Executive Director, Pro Tem 103 Hemm Road j

Piqua, Ohio 45356 Gentlemen:

Thank you for your letter dated February 3, 1981 with oath dated May 26, 1981, informing us of the steps you have taken to correct l

the noncompliance which we brought to your attention in our letter

<tated January 2, 1981.

1 Regarding Item No. 1, Dr. J. Cooper is no longer with the hTC.

Dr. B. Mallett has replaced him.

If you have any questions about Item No. 1, you can contact Dr. Mallett. lie will be able to help you.

I Your cooperation with us is appreciated.

4 Sincerely.

D. J. Sreniawski, Chief Materials Radiation Protection Section 2

[hh>fI cc w/ltr dtd 2/3/81:

i DMB/ Document Control Desk (RIDS) 97 LEVcD b

JUL 101981> ~.

33 SJ ua, ma.,mma Misspts

/8 1

p RIII B I

/ reniawski Re ch hold S

a

{ $@ g($v TT

  1. '/'

1n me,13em i1em NMS LIC30 34-17646-01 PDR

I e

-\\

OINT Hoseirst Seavices.

luc.

%)

f S

w 72. MQZir'~L;LD g_:

_-~i x 3

Y 45356 (513) 7781561 Y l

103 Hemm Road, Piqua, Ohio

__ w e :3

)

Rbruary 3,1981 Mr. A. B. Davis Chief l

Fue! Facility and l

fAateriets Saf aty Branch U. S. f4uclear Regulatory Commission, Region lli 799 Roosevelt Road Cien Ellyn, Illinois 60137

Dear tar. Davis:

This letter is in response to the telephone call f rom lAr. W. P. Reichhold January 30, 1981, concerning the clarification of item number two in FAr. fAacfAillan's written re-sponse of the 27th. The following address each specific issue with the revision of number two.

1.

This item deals with the f act that Joint liospital Services, Inc., used by-product material at Piqua IAemorial Hospital and Vhtson TAcmorial Hos-pital which also have specific licenses.

Corrective Action Per a recent phone conversation w;th Dr. Cooper, this itern will attempt to be reconciled following a visit by him to Joint Hospital Services to again review the situation and to determine possible alternative methods of structuring the licenses.

2.

This item d a!s..ith the fact that durior; the inspection there were licensed materials in an unrestricted area which were not secured against unauthorized removal, neither were they under constant sur-veillance, nor irnmediate control.

Carrective Action i

All nuclear medicine personnel were informed and instructed to follow Regu ation 20.207 A & 3-Storage and Control of Licensed fAaterials in Unrestricted Areas.

t

/

h s

l w

g

-I f,-

i

{

~

,,,y l'

[.

}

i

.U

Mr. A. B. Davis Pace 2 February 3,1981; s

3. This item deais with the fact that radioactive materials were being de-livered to a location other than Joirit Hospital Services.

Corrective Action All radioactive rnatorial is again being delivered to Joint Hospital Ser-vices. As of this date, all suppliers have been notified and deliveries are being made to Joint Hospital Services. Full compliance regarding this point has been achieved.

Respectful submitted.

7(

//f/

f g

Robert D. Severn Chali man Administrative Committee Executive Director Pro Tem RDS:bj May 26,1981 Per your letter of May 1,1981, and telephone request of May 26, 1981, the following affirmation is added:

j On this date and to the best of my knowledge and belief, the above statements j

as appears over my signature are true and correct.

l

. -- - s-j Date N

V Robert D. Severn

'd Executive Director, Pro Tem Chairman, Adminis' ative Committee 1

$f Sat 1

Bett)VJ ckson, Witness