U.S. NUCLEAR REGULATORY COMMISSION 4

+

OFFICE OF INSPECTION AND ENFORCEMENT REGION I Report No.

70-371/81-06 Docket No.70-371 License No. SNM-368 Safeguards Group 1

Licensee: United Nuclear Corporation 67 Sandy Desert Road Uncasv111e, Connecticut 06382 Facility Name:

Naval Products Inspection At:

Uncasville, Connecticut Inspection Conducted:

March 19-27, 1981 Date of Last Material Control and Accounting Inspection:

March 2-6, 1981 Type of Inspection:

Announce4 Material Control & Accounting Inspectors:

e.;.p2m A

b_,

MovIk30 1C 8I f

I. Cohen, Chemist.

date signdd b

S0.1 %' I t

A. Della Ratta( Auditor dite sighed bher A$ '-i M E/

H. Zibul uky,M hemist N

date signea Approved by:

2 yR.> h 4, #

4 /Fe /P/

(Jayes H. Joynirf, Ac1(ing Chief date sig'ned r

t luclear Materral Control and Accountability Section, Technical Inspection Branch Inspection Summary:

Inspection on March 19-27, 1981 (Report No. 70-371/81-06)

Areas Inspected:

Physical Inventory Procedures, The inspection involved 154 inspector-hours onsite by three NRC inspectors and was begun during the regular hours.

Results: The licensee war found to be in compliance with NRC requirements within the area examined except for the following items:

1.

Failure to clean the Eridgeport machine of enriched uranium metal chips in accordance wfth the FNMC plan.

2.

Failure to tamper safe the caged area located in ICA-1 in accordance with the FNMC plan.

3.

Faillre by an employee to use the contamination monitor piior to l uving a contro11r.d area (MBA-3).

1 0107100315 810507 i

PDR ADOCK 07000371 C

PDR

..