l 7

e Metropolit.n Edison Company Post Office Box 480 b

4 L

Middletown, Pennsylvania 17057 Writer's Direct Dial Number July 2,1981 L1L 197 Office of Nuclear Reactor Regulation Attn: John F. Stolz, Chief Operating Reactors Branch No. 4 U. S. Nuclear Regulatory Commission Washington, D.C.

20555

Dear Sir:

Three Mile Island Nuclear Station, Unit 1 (TMI-1)

Operating License No. DPR-50 Docket No. 50-289 Loft Test L3-1 As discussed in our Mtter of April 22, 1981 (L1L 120) in response to your letter of February 24, 1981, enclused please find a copy of B&W Post Test Evaluation of LOFT Test L3-1.

B&W's Post Test Analysis for Semiscale Test (S-07-10D) will be provided by July 15, 1981.

Sincerely,

\\

. D. 11 ill Director, TMI-l HDH:LWH:hh Enclosure cc:

B. H. Grier D. Dilanni t0 m

a v-as 4

E

[a

-8 2

JUL 0 71981

  • 1 u.s. g33

/

s

(

-(h a

e t \\

8107070364 81070gyop lit n Edison Company is a Member of the General Pubhc Utilities System PDR ADOCK 05000289?

P j_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _

s

- dj

' bg ^!

v:#

.2 -

.. :4a

'~;k -

4 it'

,s '
,n

J Q

us Saw 1

B&W's Post Test Evaluation of LOFT. Test L3-1

-}-

Document No. 51-1125988-01 J.

May 1981 11

'i 3-4

..1,.

Princi;al Ir:vestigate r K. K. Savani 3

~~

R. C. J:-=s bi -

e.

4 -:

? e.: r -2 t y C ~,.3

,,, L.....,.,--...,

n s..~ a

. : ~.a.

f:

~

1 yg-e The Owners Greco of Babcock L '.'ilcox 1l, 177 and 205 FA NSS Systems a

B/b40v'oisv w

-fwarmoto-arramstwMt %*rs % cs** +a**

P t;tt.4t* T_ M "d*4*E N***

  • T* **'* W 9.NT *
  • M'*** "* -

s.Am****

1 c:. o '

TABLE OF CONTENTS I

d Page

li
1. -INTR 00uCTiON 1

r, i

'2.

SUMMARY

2 L '

.3.

~ DISCUSSION OF RESULTS 3

[J.

}'

4..' CONCLUSIONS 10 t.

il-5.

REFERENCES 12 L

Il

6... TABLE' 13

!F p

-7.

FIGURES 14 t.;

O LJ '

F9'

.b

.s ci t

L'

~

1 t)

U.-

,j sJ

? ^

9

=t-U h.

.g r

s J

-q

-Q9 c m - m e - -,......-.~. - - w.+ -.~.- - - e:

~~-~~~%

  • r.--v m ~ v - w w+. e w e*.ww w - - -

=

.rj id

,i1

!j 1.

INTRODUCTION B&W's pretest predictions for LOFT Test L3-1 was submitted to tt. ' NRC by Reference 1.

The test was designed to provide data for a PWR simulated 2.5

[

percent single ended break in the cold leg with ECCS injection limited to the intact loop.

The break was largc enough to cause system F

depressurization.

L The test has been completed and the comparisons of pretest predictions to g)

[]

the test data have been published in Reference 2.

Inspection of this comparison shows that certain discrepancies exist between the protest

  • 1g predictions and the test data.

Based on these discrepancies.

Mr. R. W. Reid of the NRC sent a letter to all Babcock & Wilcox Licensees l

I

[]

(Reference 3) requesting the submission of a post test evaluation of LOFT Test L3-1 and Semiscale Test S-07-100, According to the letter, the objectives of this post test evaluation are-n

.5

.2 1.

Evaluate the code predictive capability using initial and boundary y

conditions consistent with the actual test data,

'}

2.

Identify code modifications and/or improvements necessary to Jn predict the test data, V

3.

Assess whether any improvements and/or codifications necessary for code predictions to agree with test data should be incorporated 3.

in present ECCS scall break evaluation models,

'l t

4.

Identify shcr;;;; M:s i. tne test fa:ility, instru sntatien, J

ttc., a-d insir i ;;a-

7. : fz m :i ti.v. :1 a:ility, and

.I re :=c4 in:r:ve r:s 1: tne test f a:il ty, inIt' :-=-t ati:n,

or test ceccedures to '= *:ve 1*e ve-ificatic9 ; ::ess.

,?

1 4

a -

'12

.h mm u m,,s..,,.mw.,m

,,,p.m-

)

1 U

t

's S

This report is in ecsponse to Mr. Reid's letter.

It provides B&W's post test evaluation of LOFT Test L3-1 and addresses the above mentioned q

jJ objectives. The post test evaluation of S-07-100 is provided in Reference 4.

b 2.

SUMMARY

]

This report is a pa tial response to Mr. R. W. Reid's lett?r requesting the submission of a post test evaluation of LOFT Test L3-1 and Semiscale Test g

!d S-07-10D. This report provides the post test evaluation of the LOFT 3-1 Test.

x

.)

LuiT Test L3-1 was a 2.5 percent single ended cold leg break with a nuclear 4

core initially operated at a power of 50 MW.

The pretest prediction of the u

test was performed using the CRAFT 2 computer code and was submitted to the l

NRC by Reference 1.

The pretest prediction performed by B&W compares favorably with the test data. However, it is recognized that the comparison shows that cetain discrepancies exist between the pretest predictions and the test data.

A l

detailed review of the results of L3-1 is performed and the sources of these dis'crepancies are identified. Qualitative justification is provided in this

}

report demonstrating that if these sources of discrepancies were eliminated, the prediction would be in better agreement with the test data.

1 1J Relative to the objectives of the ::st test evaluation ider.ti#ied in Reference 3, the post test evaluati:n f L-ri Test L3-1 ::nfi e: tna the

,j CRAFT 2 computer code can predict c s al; crea'< LCG :~ e-~ t-a ::sens: S the test, proviced that adequate tes ecr. i.ict.s are cr:. ;;E:. n: :::e l

r.odificaticns are delieved to be re:assary 'r : e :re:ini:n.

3 :r e- ::

inprove the verification process, it is cr;ected tha*. I 2'r#~1 I : :i:-

LA 4

g 3

1 I;)

q.

i 9 <

___,_.,_____.____,_____r..______m.

N2 I5l J

to that utilized for the recent L3-6 prediction be employed.

That approach consisted of setting up a " blind pretest" model. release of the test data, and then a post test evaluation where the changes from the " blind pretest" model must be justified.

1"l J

3.

DISCUSSION OF RESULTS 3

3.1 Pretest Prediction 7J Via, Reference 1, B&W's pretest prediction of LOFT Test L3-1 was submitted to the NRC. A detailed comparison of the prediction to the actual data was l

II performed by EGLG and is documented in Reference 2.

As is shown by that j

report, the B&W prediction compares favorably to the experimental data.

- n LOFT Test L3-1 was a 2.5 percent single ended cold leg break with a nuclear i

core intially operated at a power of 50 MW. The major components of the 3

LOFT facility are shown in Figure 1.

The CRAFT 2 noding diagram utilized for the L3-1 pretest prediction is shown in Figure 2 and described in Table 1.

!:)

The LOFT L3-1 system description and the initial conditions used for the

.I pretest prediction were obtained from References 5 and 6.

During the L3-1 test, some of the actual conditions were different ths.n the initial 1

conditions provided by EG1G ba',re the test.

These differen:es between the d

initial conditions and the actual conditions are described celow:

1 1.

In the test, the auxiliary feed pump was started at 75.0 seccnds j.)

l, while in the EL'a' pretest prediction, the an.iliary feeuzter was

' started at 60.0 setends based on the ir.itial ::rcici:ns ;r:vided by j

EGLB.

ii t

ww y o

e :

e b,

.5 t<

i 2

,_f

,,,g,,

og,

,,9 ww

,w.

i The specified initial accumulator pressure in Reference 6 was 2.

3 600 psig.

The actual measured pressure of the accumulator during J

the test was 633 psig.

3.

During the test, two leakas e paths occurred, which were not identified to the participants who were attempting to predict the tea

Hence, 7,

these leakage flow paths were not modeled in the B&W's pretest prediction model.

9 I*

4.

No specific information about the steam flow control valve was provided in the initial conditions, e.g. flow area, the percent initially open,

$L how fast the valve closed.

No pecification on leakage through the steam flow control valve was provided.

Examination of more recent LOFT Tests, L3-7 and L3-6, indicate that there is some leakage through the main steam control valve when it is in its fully closed position (Reference 7).

Based on conversations with EGtG personnel, the steam valve was assumed g

d to be 75 percent open, and to close at a rate of 5 percent per second to the fully closed position. The effective steady-state flow area was 7j calculated based on the Moody Critical Flow Model and area was changed as a function of secondary side pressure.

No leakage through th. valve

' ~I was allowed when the valve was in its fully closed position.

J As can be seen, there are several significant discrepancies between the 1

3 initial conditions asstned in the analysis and the actual system conditions of the experiment.

The impact of these differences en the prediction is y

j described in the following section.

h 1

^

3 4_

6 eJ

i

)

3.2 Post Test Evaluation

<1 d

In this section, the comparison of B&W's pretest prediction with the test data is provided.

Along with this comparison, the discrepancies between i

B&W's prediction and the test data are explained based upon the differences in assumed and actual system conditions described above.

(1 U

3.2.1 Steam Generator Secondary Pressure rn b

In this test, the steam generator secondary side pressure quickly rose after the reactor scram due to the closing of the steam flow control valve.

In q

j the test this valve did not open during the initial 1500 seconds of the transient. The auxiliary feed pump was started at 75 seconds cooling the l

e 1

mixture in the steam generator.

L

]

The steam generator secondary side pressure comparison of the pretest prediction and the test data is shown in Figure 3.

It is obvious that the calculated secondary pressure exhibited the same trend as the test data; O

however, the pressure was underpredicted slightly for the first 250 seconds l

and then overpredicted from 400 seconds on.

.t J

As' explained earlier, in'B&W's pretest prediction, the steam flow control l

~t valve was assumed to be 75 percent open and to close at a rate of 5 percent J

Or second to the fully closed position. The auxiliary feedwater was i

sta-ted at 50 se::r.ds.

.'l.

In the actual test, the zuxiliary feedwater was started at 75 seconds.

t;o s:e:ific infer ation at:v. the steam flow control valve perfcrmance is previded to co care it with the B&W's pretest prediction nodel assumption.

a 3

my

' v i

b

,1

By modeling the steam flow control valve exactly as it behaved in the actual test, the steam generator pressure prediction is expected to improve.

It is l

felt that the steam flow control valve was probably open less than 75 percent initially and thus, was fully closed earlier than calculated.

The initiation of auxiliary feedwater at 75 seconds, as it happened in the test, is expected to bring the predictions in better agreement with the test data during the early part of the transient because the steam generator cooling will be delayed.

Examination of recent LOFT tests indicate that there is leakage through the steam flow control valve when it was in its fully closed position (Reference 7).

In the B&W pretest prediction model, no leakage through steam flow control valve was allowed.

It is expected that there was probably leakage in the L3-1 test.

Inclusion of steam flow control valve leakage would l

result in a faster steam generator > pressurization more typical of the experimental data.

3.2.2 Intact Loop Accumulator Pressure The accumulator injection during the test was initiated at 634 seconds after j

the rupture.

The measured initial pressure was 633 psig.

The specified initial accumulator pressure in Reference 6 was 600 psig.

Figure 4 shows it.e comparison of the B&W's calculated accumulater pressure

l. -

to the test data. As can be seen. B&W's predicted accumulater pressure g

ii l1.

resp 0r.se stews a t end similar to the test data indicatir: that t"e L.

accumulator er::'ed at a rate sir.ilar to the experi ent.

The riserepancy prirr te the i tiation Of tre a::; ulat:r is due :: tre :ifferer:e tetween the ir.itial C 5!iti:CS girer. aCC tne a:tbal test C:r.

  1. . i:05.

ELn"s fretest

-=- in Lne #.itilii r. Of the a :utu'.a:Or fi. a 350 predicticr. rec '

t se :r.ds. ~he in'tiation " =~ - lat:- flow just cue to the :-::er initial 1'

i l.

J

..v-

<!)

._,,,,,_,y-_.,

~

accamulator pressure alone will result in ne100 second earlier initiation of accumulator flow.

Also, the expected improvement in the system pressure I

prediction by utilizing the actual test conditions in the pretest prediction model (as discussed in Section 3.2.4) will further improve the predicted

)

time of accumulator actuation.

3.2.3 Break Flow Figure 5 compares the leak flow rate of B&W's pretest prediction and the

['

test data.

The predicted break flow exhibits the trend of the data for the L

initial 50 seconds and from ^e 500 seconds on. The pretest prediction over these time frames is within the range of the test data.

The predicted break flow between 50 to 250 seconds is essentially constant anf significantly higher than the test data.

The predicted break flow then sharply drops and is slightly lower than the test data up toes 500 seconds.

This discrepancy betwecn the predicted break flow and the test data is prim'rily due to the leakage paths that existed in the test.

During the 1

a I

test, leakage through the cold leg warm-up line, reflood assist bypass valves and from hot leg to downcomer occurred. These leakage paths were not s

i,I identified to the participants who were atterpting to model the test.

Because of these leakage paths, there was a direct path for the hotter fluid

)

of the system to be transporten and mixed at:n the fluic at tne break.

Consequently, subcooled liquid discharge will end earlier and there will be

"]

a smoother transition thrcagh tan phase f'.ca ;c steam, chich n'as typical cf the actual experiment cata.

n

.i

.. ~

.[

es i

9 i.

. i.]

i.

In B&W's pretest prediction model, these leakage flow paths were not modeled.

Therefore, the predicted break flow during the first 250 seconds of the transient is subcooled liquid as no steam relief path to 6%o break is available until the loop seal is cleared.

The clearing of the loop seal will decrease the break flow sharply as a result of a sudden decrease in the density of the fluid at the break.

The slightly underpredicted break flow between 250 to 500 seconds is due to the discharge model utilized in the prediction model and as a result of the earlier difference between the prediction and the test data.

The Bernoulli-Moody Discharge Model with a discharge multiplier of 0.6 for subcooled and two-phase flow was utilized in the prediction.

The discharge multiplier was changed to 0.9 when the break flow stabilized at pure steam.

In order to predict the two-phase discharge flow precisely, the discharge multiplier should be changed as a function of break fluid quality. The expected transient of the test without the leakage flow paths was a long duration subcooled liquid discharge followed very quickly by a transition to steam.

Hence the two-phase discharge was expected to occur only for a short time during the transient.

Based on this, the discharge multiplier for the entire two-phase discharge flow was i

kept constant at 0.6.

The discrepancy between the predicted break flow and.

the test data during 250 to 500 seconds is essentially due to the constant

}

discharge multiplier of 0.6 for the entire two-phase flow and the earlier difference between the prediction and the test data.

In sh:rt, the predicted break flow compares reastnably well with the test data.

T.s predicti:n is sxps:ted to imprcve significantly if the act.E'.

test ::rciticas (leakare ;tths) and the ccre a::r::riate discharge ncdei f:r the test are utilizec in the prediction model.

~

9 4

.-w e

" E r-

.ii

(:r i l

-- - n s

J-t 3.2.4 System Pressure In the test, the system pressure was characteri7ed by a rapid depressuriza-tion to the system fluid saturation pressure.

The depressurization rate then decreased until 300 seconds when the system liquid level decreased below the break orifice, allowing stecn to escape and the system to depressurize more rapidly.

From 1000-15000 seconds depressurization rate was decreased as a result of the liquid level in the broken loop increasing above the break orifice.

1 Figure 6 shows the comparison of B&W's pretest prediction with the test l

data. The prediction generally shows the same trend as the test data and is in good agreement with the test data.

However, it is recognized that the I

pressure is slightly under predicted from 50 to 2'00 seconds and over predicted from 600 to 1100 seconds.

The initial underprediction of the pressure is mainly due to the fact that steam generator secondary side pressure was underpredicted during this time frame.

During this period of time, the fecondary side pressure controlled the primary side pressure.

Thus, the expected improvement that could be abtained in the steam generator presse-e would irprove the primary system pressure comparison.

The long term overpredicticn of system pressure is due to a combination of various factors.

  • s centioned earlier, the pretest prediction did not include the leakage aths. With the addition of these i,

leakage paths, as explained in Section 3.2.3, the break flow prediction can U

be improved and this would i= prove, the system pressura with the test data.

1 l

As discussed in Se:ti n 3.2.2, Er.'s :-etest predi:t :n cf a::: alater i

1 initiation was late-an :ne trutzl tect-T-is w:: ;mrtially z result of the difference betwee-tne initial ::r:#if:r riven ' " --= =-~' =1 test condition of the a:0 7;Iat:r. 'With ins i-itiati:n Of tre a::umulatcr, steam will be condensed an: nc :e a m:-e rz:': rytter ce:-essuri:1-icn will take place. The delaye: :recitted a :umult::r actuation : ntricutec to the over i:

prediction of the system cressuee.

\\

A

_g_

11 i i L

i

> P m m--aw_~-~~

~~ -----~~--~ ~ ~ ~ -- - ~-*~~~-

w -

~g~

The steam generator secondary side became a heat source in B&W's pretest prediction at about 400 seconds.

During the pretest prediction, no leakage through the s' eam flow control valve was allowed once it was in its fully closed position.

If in the actual test, leakage throuah the steam valve existed once it was in its fully closed position, a portion of the secondary side energy would be released through the leakage and hence less energy would be added to the primary system.

This also contributes to the over-prediction of the system pressure in B&W's pretest prediction mcdel.

In short, B&W's pretest prediction of the system pressure compares I

reasonably well with the test data.

The difference between the prediction and the test data is a result of the differences between the assumed and l

actual test conditions.

4.

CONCLUSIONS In general, B&W's pretest predictions of the L3-1 test are in good agreement with the test data.

Review of the comparisons of B&W's pretest prediction and the test data by EG&G in Reference 2, reveals that the predictions i

exhibited the same trend as the data for all the parameterc compared.

It is recognized that the comparison shows that certain discresancies exist between the predictions and the test data.

The differences between the l

predictions and the data are due to differences in the ass. red and actual system conditions.

The qualitative analysis provided in tris report demonstrates that incorporation of the actual experimental conditions would result in an improved prediction.

Relative to the objectives of the post test evaluatien, =' e ='=" in the February 24, 1981 Reid letter (Referer.:a 2;, -he feli:w7n: ::nciusions are drann:

1.

The evaluation of LOFT Test L3-1 ::

'#- ec that - e CRAFT 2 :: ruter code is capable of predictir: trs s a : sa< ' :: : en:re a observed in the test if the a:tual test c0r.diti:ns nere utilice:.

~

'9.

t

  • e

... -. ~.. - -.

t 2.

No code modifications are believed to be necessary to predict the test.

t 3.

Since no code modificatiers are necessary to predict the test, no modifications to the present ECCS small break evaluation model e,!

have been identified from this 2xperiment.

e f

. )

1-4 e

A L.

I r 5 :

{.-

l 1 t_.

I i

    • 4 i

.J m

4

.eeip' n s 9

N

. i

  • k.

ri.

il

~

?

8

- 5.

REFERENCES 1.

Letter from J. H. Taylor to D. F. Ross, "B&W's Best Estimate Prediction of the LOFT'L3-1 Nuclear Small Break Test Using the CRAFT 2 Computer Code," December 13, 1979.

2.

Czapary, L. S., " LOFT L3-1 Preliminary Com'parison Report" EGG-CAAP-5255, dated September 1980.

3. ' Letter to All Babcock & Wilcox Licensees from R. W. Reid, Chief Operai.ing Reactor Branch #4, Division of Licensing, February 24, 1981.

4.

T. E. Geer, et'..al., B&W's Post Test Analysis For Semiscale Test S-07-100 Doc. No. 86-1125888-00, May 20, 1981.

5.

LOFT System and Test Description (5.5 ft. Nuclear Core 1 LOCES),

NUREG/CR=0274, TREE-1208, Reeder, D. L. dated July 1978.

6.

Information for L3-1 Standard Problem, Kaufman, N. C., Kau-203-79, dated September 28, 1979.

7.

Modro, S. M. & Condil, K.

G., "Best Estimate Prediction for LOFT Nuclear Experiment L3-5/L3-5A," EGG-LOFT-5240, dated September 1980.

J

)

d I 'r l

e

'\\,E w-.-

O --

d l

_ - - - - i_ _ _ - - _ _. _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _. _.. __., _ _ __,_,.. __

Table 1.

Node Description Node No.

Description 1

Downcomer annulus 2

Downcomer 3

Lower plenum 4

Core 5

Upper plenum & upper head 6

Pressurizer 7

Hot leg, intact loop 8

Steam generator, front half of primary sida, intact loop j

9 Steam generator, back half of primary side, intact loop 10 Steam generator outlet, cold leg piping, intact loop 11 Pump suction, intact loop 12 Pump discharge, intact loop 13 Hot' leg plus half simulated SG, broken loop 14 Half simulated SG plus half pump, broken loop 15 Half pump plus piping, broken loop 16 Leak node 17 Suppression tank 18 Secondary side, intact icop V

v'%

O d

_13 r

' i. }

~

1 1,

3 M

o

.. _ !")".I.A '"?I' m _

Broken loop I

i Oulek opening valve (2) l Steam 3

[W-generator Y

8I"'utator jtj

.i i

=

v 5

f cd.

l'n g urtisi lit t,601 s

(pst,6tlot r

}

M g h D ',

Si,

'I.

. Isolation f

g

  • k

, 5,-

,) s

% valve w,-

r'

.s,

l a

~ N Pump

'N P

5 3

simulator.

t

~ECC injection m

h location v

( '

Pumps

.t.

l' q

b&

,)

'{T~K r d' F

fleactor I

i vesse!

j',Q

'V Suppression l

,! g;!,

l,,,) Downcomer vesse!

.i

,h-Core I

! ll l'

)

l OWftf pit'fillm

(

}

! l,' l E M8S? 3 fitmi tot g e :i,i'l.

3! rare 1.

I.OIT mejor components.

~

E 7

R 1

A E

8 h

D O

N E

O D

T e

o ON &

8 8 O K

AhSi E

l L

T A

P l

Sl W

6 i

1 T O A L l

P F f

E 7

K D O A 0 L E N F L oo)

@ a, 3

e r

C C

g o (A' 8

8 M

A 7

R 1

GA 2

I D

4 7

GN 2 s

I D

e O

r N

ug 1

i h@2 h

T F

3L i

2 FO

@ g h

L 3

g

.4 e @g

)

3 1

Bg

~

4 1

n o

h j

f\\,l!I:

B b

y OO g

i i/

O

//

//

>x

//

<o

//

ZO

/ /

OLd J

W

//

m

//

R om

//

<==

San

//

oa C

o o W.

,aem o o

$5'

[

r-( LO Ld s

Y

~

thS 3 j/

f R

5

/ l/

2 to i

i I

/

O.

LO to

/

n i i

//

b 8

I i

//

H 3

e m

c,

//

o z

a

//

O u.

m

//

l-e

//

o.5 8 '2

//

O F-OO

~

to 1

/

<O

+

0-

/

EW o=

//

z8

/

/

Om w td

/

wt Cb

~

l fw

//

//

ga om i i

\\ s - _. - -

m-o O

-O O

O En O

.0

~J N

O N

r=4 r-i Q

(UTSd) EIr.2EElf e

4" t

6 n....-.%%.,

..,,,,,--w..,,.%,,,,.,,._~%,y,..-~.,,,...,._..-,,,c.

....-_w.

e e

e O

O LO s

. /

a

/

/

/

x

/ /

os

/

~

//

W

//

d

//

o noe o

'5 A=5

/I

=

255 f/

1o amu

//

o 2 S

2 o

e

a. D M

7 /

a o

t I y

/ /

<H t I t l

//

Ou Z

7 I I 3

o f /

f/

a k

o o

v

,/

m o

//

u z

w O

O 3

/

.+ /

Y m

O DO 1 1 o

.E

,-4 J

r gk a

o O

1j

=

g e4 1

1 4

1 ma 1

l1 o

zr o

l V) 12 i

11 s8 E Ei 11 EE i

11 l-oc-it o

o o

Li >

O t.D P-C N

^

(e7sc) erssar;-

e i,

i,

'.)

4

.,_y_,

11 0 TTE-Bl-1 l

)

--- UPPER BAND

\\

L0t!ER BAND

\\

B&tt y

\\

\\

\\

n u

( ')

w

~

\\

\\\\

i 5

\\\\

7 0

20

\\\\

\\\\

m E

\\ \\

\\>

i

\\ \\ N l

,I i

10

' N\\

l l

f c

~

~

0 i

O 500 1000 1500 Tima After Rupture (Sec)

COMPARISON OF B&Yi CALCULATIONS OF BREAK MASS FLOff TO OATA Figure 5

~

9 s O 6

OO to 4

6 e

l g

II dl

+a l

a

/l f?

fIl w

==

y l.

B 7M

/11 bu~

ll IEE E 11 8^

jj Oy g

mma m Z

i 8

/ I

,d l i e

i I

/ /

9 a

8 i

/ /

3

//

-9 W

//

z n.

e D

//

4 0

3

,/,/

O a

u) w

/

z Lt.

I o

O

/

o.!i p

O F-4

/

f LD

.J e

B

//

.J*

/

o

/

u.

I O

I z

I lf m

$ lI m

C

-c:

=

0 O

O O

O in O

O N

M M

(en ) a2nssard i

e 8

5

- 19 i

O

,-..,~-w---w.w.,ne.-