ML20008F913

From kanterella
Jump to navigation Jump to search
Provides Determination of Consequences Re Water Leakage Into Dry Spent Submerged Demineralizer Sys Ion Exchange Vessel. Leakage Presents No Dangerous Impact Due to Venting in Vessel Design.Addl Tritium Release Considered Insignificant
ML20008F913
Person / Time
Site: Crane 
Issue date: 05/05/1981
From: Hovey G
METROPOLITAN EDISON CO.
To: Barrett L
Office of Nuclear Reactor Regulation
References
LL2-81-0118, LL2-81-118, NUDOCS 8105120304
Download: ML20008F913 (2)


Text

,.

P 4

Metropolitan Edison Company to sN, Post Office Box 480 f h' gj

'e g\\

MiCdletown. Pennsylvania 17057 A

c

[31 s

3 8L

. y 'C-w,ite,oi,w o,. %,,ou MAY 111981*g 1

May 5, 1981 M p s.mata uauwoes J.

LL2-81-Oll8

.f comunae A

h M

h@

TMI Program Office z

Attn:

Mr. Lake Barrett, Deputy Directsr 4

U. S. Nuclear Regulatory Commission cn g

c/o Three Mile Island Nuclear Station no Middletown, PA 17057 h

=

Dear Sir:

U u

52 Three Mile Island Nuclear Station, Unit 2 (TMI-2)

Operating License No. DPR-73 Docket No. 50-320 Submerged Demineralizer System During discussions with members of your staff you requested that we provide an analysis to determine the consequences of possible water in-leakage into a dry, spent SDS ion exchange vessel. This letter provides our response to your request.

In the unlikely event that water leaked into a dry, spent SDS vessel while in storage and the maximum centerline temperature had been reached, the water would flash to steam. As a result of the gener-ation of steam three primary consequences could result. They are:

1.

Steam would enter the storage vent header.

2.

Pressure in the vessel would increase if the vent header were plugged.

3.

Increased tritium levels in the offgas.

Steam entering the vent header is prohibited from depositing on the offgas HEPA filters by virtue of its passage through the offgas separator where condensation of the vapor occurs.

Water inleakage to a dried, spent SDS vessel would not present a dangerous situation due to the venting provided in the vessel design.

However, the vessel will remain intact even if the vent were plugged.

Worst case inleakage would occur if water is introduced to the hot centerline resins. Calculations show that a maximum centerline temperature for the zeolite could be as high as 435'F for 60,000 (Cs-137) curie loading of the SDS liners. Water contacting these resins would be vaporized.

The SDS liners are designed to withstand an internal pressure of 350 psig and will be hydrostatically tested to a pressure of 525 psig.

Saturated steam at the projected centerline temperature of 435'F has an dd

)

b/8 Me:mcmtan Ecison company is a Member cf :ne General Pt bLc Urtht;es System

_810 512 030t[

w. V Mr. Lake Barrett LL2-81-Oll8 absolute pressure of 360 psi.

Steam produced by this mechanism would not rupture the vessel, ignoring 1) the venting and 2) the cooling provided by the heat sink of pool water and 3) significant external pressure. Any heat of hydration released upon inleakage to a dried bed would be dissipated to the heat sink provided by the fuel pool, and the vessel would remain intact. Furthermore, such a dried bed is not expected to exist; the SDS zeolite liners will be stored sub-merged under " wet" conditions and will not self-dry to any appreciable extent. Calculations show that the minimum dehydrating time for a 60,000 curie-loaded bed is approximately fourteen years.

Althoegh it is possible, under water inleakage conditions, to increase the amount of tritium released in the SDS offgas, this additional amount of tritium is insignificant. Our caleglations indicate that the additional tritium released will be 1.2 x 10 pCi/sec. This compares to a normal tritium source term of 8.14 uCi/sec.

Should you have any questions or wish to discuss this matter, please contact Mr. L. J. Lehman, Jr. of my staff.

Sincerely, J'K r

G. K. Hovey Vice-President and Director, TMI-2 GKH:LJ, cc:

Dr. B. J. Snyder, Director - IMI Program Office t

4

= *

  • r v

e w-m 4

y