ML20008F610

From kanterella
Jump to navigation Jump to search
Forwards YAEC-1233, Methods for Analysis of Bwrs,Sys Transient Analysis Model (Retran). Rept Describes Methods for Reload 8 Safety Evaluation
ML20008F610
Person / Time
Site: Vermont Yankee File:NorthStar Vermont Yankee icon.png
Issue date: 04/17/1981
From: Marsolais L
VERMONT YANKEE NUCLEAR POWER CORP.
To: Ippolito T
Office of Nuclear Reactor Regulation
Shared Package
ML20008F611 List:
References
FVY-81-70, NUDOCS 8104210373
Download: ML20008F610 (1)


Text

-

VERMONT YAN KEE NUCLEAR POWER CORPORATION SEVENTY SEVEN GROVF. STREET RUTLAND VenMour osvon FVY 81-70 REPLY TO:

ENGINEERING OFFICE 1671 WORCESTER ROAD FR AMING H AM, M ASS ACH USETTS O1701 TELEPHONE e17.e72-eioo April 17, 1981

[\\k 4

United States Nuclear Regulatory Commission 9

N Washington, D. C.

20555 g'

L g

g q,

-2 Attention: Office of Nuclear Reactor Regulation Mr. Thomas A. Ippolito, Chief kJ x y

y Operating Reactors Branch #2

/A #

Division of Licensing

{t p

References:

a)

License No.- DPR-28 (Docket No. 50-271) b)

Letter, R. L. Smith (VYNPC) to T. A. Ippolito (USNRC) hVY 80-76, dated May 15, 1980 S ubj ect:

Submittal of Documentation for Core Reload Licensing Methods D car Sir:

The purpose of this letter is to forward the attached document, YAEC-1233, " Methods for the Analysis of Boiling Water Reactors, A Systems Transient Analysis Model (RETRAN)".

This report describes methods which will be used to perform safety evaluation of Reload 8 for Vermont Yankee, and is submitted in accordance with the commitments made in Reference (b).

Should you have any questions regarding the attached report, please contact us.

l Very truly yours, VERMONT YANKEE NUCLEAR POWER CORPORATION CvW e L. D. Marsolais VY Operational Project Manager 8104210

  • P