l J
O, Form NRC418 U.s. NUCLE AR REGULATORY COMMISStoN CERTIFICATE OF COMPLIANCE jo CFR 71 For Aadioactive Materials Packages 1.fal Certificate Number 1.lb) Revision No.
1.f cl Package Identification No.
1,(d ) Pages No. 1.tel Total No. Pages 9145 1
USA /9145/A 1
2
- 2. PRE AY8LE 2.tal TNs certificate is isswed to satisf y Sections 173.3934.173.394.173.395, and 173.396 of the Department of Transoortation Hazardous
?.taterials Regulations (49 CFR 170183 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Cecartment of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amerdad.
2.Ibn The pacnaging and contents cescribed in item 5 below, meets the safete standards set forth in Subpart C of Title 10. Code of Federal Regwlations. Part 71. Packaging of Radioactive Materials for Transport and Transportation of Radioactive P.*aterial Under Certain Conditions /*
2.f c)
This certifacate does not relieve the consignor from compliance with anw requirement of the regulations of the U.s. Department of Transocrtation or other applicable regulatory. agencies, including the government of any country through or into wNeh the package vwill be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.lal Prepared by (Narne and address):
3.(b)
Title and identification of report or application:
Nuclear Packaging, Inc.
NUPAC application dated September 19, 1980, 815 South 28th Street as supplemented.
Taccma, WA 98409 3.fc)
Docket No.
71-9130 4 CONDITIONS This certificate.s conditinnat upon the fulfi!!ing of the requirements of Subpart D of 10 CFR 71. as applicable, arid the conditions scocified in item s below, f
- 5. Cescription of Packagsng and Ai.tnorized Conte its. Model Numoer. Fessile C! ass. Otner Cono.tions, and
References:
(a) Packaging (1) Model Nos.:
NUPAC 50-1.5L, NUPAC 50-2.5L, NUPAC 50-3.0L, and NUPAC 50-4.0L (2) Description A steel encased lead shielded casks for low specific activity radioactive material.
The casks are right circular cylinder with a 48.5 inch inside diameter by 52.5 inch inside high cavity.
The walls of the casks contain a lead thickness ranging from 1.25 to 3.75 inches encased in 3/8-inch thick steel shells.
The bottom and to,o covers of the cask are made up of two, steel plates ranging in thickness from 1.00 to 3.00 inches.
The primary cask lid is secured to the cylindrical cask body by eight,1-inch rachet binders. A secondary cask lid is centered in the primary lid and is secured to the primary lid with eight, 3/4-inch studs and nuts.
Each lid is provided with a Neoprene gasket seal.
The cask is provided with four equally spaced lifting / tie down devices.
Cash gross weights range
~
from 13,200 to 28,900 pounds.
(3) Drawing The packagings are fabricated in accordance with Nuclear Packaging, Inc.
Drawing No. X-20-2010, Sheets 1 and 2, Revision B.
osnn120 M
_. =_
_ _ _ - =
i l
b i
Page 2 - Certificate No. 9145 - Revision No. 1 - Docket No. 71-9145 (b) Contents (1) Type and form of material (i) Dewatered, solids, or solidified waste, meeting the requirements for low specific activity radioactive material as defined in 10 CFR 671.4(g), in secondary containers; or (ii) Activated solid components meeting the requirements for low specific activity radioactive material as defined in 10 CFR 571.4(g).
(2) Maximum quantity of material per package l
Greater than Type A quantities of radioactive material.
6.
Shoring shall be placed between secondary containers (or activated components) and the cask cavity to prevent movement during normal conditions of transport.
7.
Prior to each shipment, the packaging lid srals shall be inspected.
The seals shall be replaced with new seals if inspection shows any defects or every twelve (12) months, whichever occurs first.
8.
The package authorized by this certificate shall be transported on a vehicle, railroad car, aircraft, inland water craft, or hold or deck of a seagoing vessel assigned for sole use of the licensee.
9.
Lid lifting devices shall be covered prior to transport to prevent its use as tie-down devices.
10.
The cask bod;' and each cask lid shall be marked in accordance with 10 CFR 571.53(c).
11.
The package authorized for use by this certificate is hereby approved for use under
-license provision of 10 CFR 671.12(b).
12.
Expiration date:
February 28, 1986.
REFERENCES Nuclear Pack.'ging, Inc. application dated September 19, 1980.
Supplements dated:
December 12 and 18, 1980 FOR THE U.S. NUCLEAR RE(.JLATORY COMMISSION 1
be v
I~CharlesE.MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and l-Material Safety Date:
04 133; r
,, _, + - - - -.
. ~. _
,----..,.-r-m.--.,--c.,
-~.._.,,..#
_w-...
< -..