O Form NRC418 U.S. NUCLEAR REGULATORY COMMISSION U
CERTIFICATE OF COMPLIANCE 10 C R 71 For Radioactive Materials Packages 1.(:) Certificate Number 1.(b) Revision No.
1.(c) Package identification No.
1.(d) Pages No. 1.(e) Total No. Pages
% 41 1
USA /5641/AF 1
3 2., PRE AMBLE 2.tal This certificate is issued to satisfy Sections 173.393a,173.394,173.395, and 173.396 of the Department of Transportation Hazardou:
Materials Regulations (49 CFR 170-189 and 14 CFR 103) and Sections 146-19-10a and 146-19-100 of the Department of Transportation Dangerous Cargoes Regulations (46 CFR 146-149), as amended.
2.lb)
The packaging Lnd contents described in item 5 below, meets the safety standards set forth in Subpart C of Title 10, Code of Federal Regulations, Part 71, Packaging of Radioactive Materials for Transport and Transportation of Radioactive Material Under Certain Conditions.**
2.fc)
This artificate does not relieve the consignor from compliance with any requirement of the regulations of the U.S. Department of Transportation or other applicable regulatory agencies, including the government of any country through or mto which the package will be transported.
- 3. This certificate is issued on the basis of a safety analysis report of the package design or application-3.la)
Prepared by 3.(b)
Title and identification of report or application:
Uni ted Nuclear (Name and address):
Corporation 67 Sandy Desert Road United Nuclear Corporation Application dated
.Uncasville, CT 06382 February 2, 1968, as supplemented.
3.fc)
Docket No.
- 4. CONDITIONS This certificate is cond;tional upon the fulfilling of the requirements of Subpart O of 10 CFR 71, as applicable, and the conditions specified in item S below.
- 5. Description of Packaging and Authorized Contents, Model Number, Fissile Class. Other Conditions, and
References:
(a) Packaging (1) Model No.:
UNC-2500 (2)
Description The inner container is a box-like construction consisting of steel sheet or 6061-T aluminum with all welded construction.
Dimensions are 7-inch 1
by 7-inch by 60-1/2-inch to 62-3/4-inch length or 8-7/8-inch by 13-1/2-inch by 88-1/2-inch length.
The outer container is birdcage construction formed 1
by a 2-inch by 2-inch by 3/16-inch or 1/4-inch hot rolled angle iron or 6061-T aluminum all welded construction. Maximum gross weight is 7,000 pounds.
(3)
Drawings The packaging is constructed in accordance with United Nuclear Corporation Drawing Nos. A-30340, A-301085, and A-30203.
81081200is m
6 Pag 2 2 - C;rtificate Ns. 5641 - Revisjon No.1 - Docket No. 5641 5.
(b)
Contents (1) Type and form of material Unirradiated fuel clusters, modules or other assemblies.
(2) Maximum quantity of material per package Not to exceed Type A quantities radioactive material and components containing U-235 as specified in Table 1001-I, Ravisions 2 and 3 of United Nuclear Corporation applications dated September 14, 1972 and December 2, 1975. The contents of a single shipping container shall be limited to one (1) rrodule or cluster.
(c)
Fissile Class (1)
For the contents described in 5(b)(1), and limited in 5(b)(2),
the maximum number of components per shipment are limited to the following:
Maximum number of Item Component comoonents per shipment 1.
Element 40 Sub-Assm 9
2.
Element 48 Removable Sub-Assm 20 Sub-Assm 8
Corner or Cluster Module 4
Cluster 2
3.
Element 22 Sub-Assm 4
< Type A Module 2
Nodule 1
4.
Element (1) 20 Element (2) 22 Pre-Assm (2) 6 Sub-Assm (1)(2).
4 Removable Fuel Assm (1)(2) 20 Cluster (1)(2)-
1 5.
Element 20 Pre-Assum (Type A, E, F) 4 Sub-Assm (Type D, or Types D ' VC, or 2 B/C) 4 Pre-Assm (Type D or B/C) 6 Cluster 1
Paga 3 - Certificate No. 5641 - Revision No.1 - Docket No. 5641
- 5. (c)(1 ) Fissile Class (Continued)
Maxir.om number of Item Component components per shipment 6.
Element 20 Outer Pre-Assm (1)(4)(11) 3 Sub-Assm (corner clus) 4 Inner Pre-Assm (2)(3)(5)(6)(8)(9)(10) 4 Corner Pre-Assm (7) 4 Inner Sub-Assm 4
Inner Cluster 1
6.
Additionally, a maximum of 700 grams U-235 or 40 grams U-235/ inch of the type and form of material specified in 5(b)(1) may compose a Fissile Class III shipmeiic.
- 7. -The package authorized by this certificate is hereby approved for use under the general license provisions of 10 CFR !i71.12(b).
8.
Expiration date:
March 31,1986.
REFERENCES United Nuclear Corporation application dated February 2,1968.
Supplements dated:
July 19, August 9, and December 4,1968; October 30, 1969; September 14, 1972; and December 2, 1975.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION hhA V&
_h
~~
Charles E. MacDonald, Chief Transportation Certification Branch Division of Fuel Cycle and Material Safety Date:
L i