ML20008E746

From kanterella
Jump to navigation Jump to search
Forwards LER 80-091/01T-1
Date released: 01/22/2020 Download: ML20008E746


LER 80-091/01T-1:on 801223,determined That Floor Beam Above Block Wall Between Control Room & Stairway AB-1 & at Top of Wall 3307 Would Be Overstressed During Seismic Event.Caused by Methodology Change.Struts Will Be Added
ML20008E749
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 01/06/1981
From: Mekbel C
TOLEDO EDISON CO.
To:
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20008E749 (3)
Forwards LER 80-091/01T-1
ML20008E744
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 03/02/1981
From: Murray T
TOLEDO EDISON CO.
To: KEPPLER J G
NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION III)
References
Download: ML20008E744 (1)