8 6

m TENNESSEE VALLEY AUTHORITY g

CH ATTA % OOG A, TENNESSEE 37401

$f v4' g *gf. 0 6 gg,

-d 2

500A Chestnut Street Tower II

,,ica.

j February 27, 1981

%t.,NIK N.

w Director of Nuclear Reactor Regulation Attention Mr. A. Schwencer, Chief Licensing Branch No. 2 Division of Licensing U.S. Nuclear Regulatory Commission Washington, DC 20555 Dear Mr. Schwencer In the Matter of

)

Docket No. 50-327 Tennessee Valley Authority

)

As required by item 2.C(9)(a) of the Sequoyah Nuclear Plant Operating Licenas DPR-77, enclosed is an engineering report which addresses the steam generator camera inspection device. This report includes the description, results, and conclusion of the preliminary tests performed using the device. We believe this device is a satisfactory alternative to the proposed inspection ports.

Very truly yours, TENNESSEE VALLEY AUTHORITY J. L. Cross Executive Assistant to the Manager of Power Sworn to ard subso prthis N M day of T./ I.before me 1981 (Ltdk 6/4MA

~

. Notary Public My Commission Expires Enclosure f

a f

8103 09 0 lej g An Eque Opw. undy Emp%ci L..