ML20008D676
| ML20008D676 | |
| Person / Time | |
|---|---|
| Site: | 07109033 |
| Issue date: | 07/25/1979 |
| From: | Macdonald C NRC OFFICE OF NUCLEAR MATERIAL SAFETY & SAFEGUARDS (NMSS) |
| To: | |
| Shared Package | |
| ML19276G676 | List: |
| References | |
| NUDOCS 7908160560 | |
| Download: ML20008D676 (4) | |
Text
/
a. *W
/
6 e
f " ' ce'w N H C 418 U s. NUcLL AR Rf GUL ATOR Y COMMis5loN
) (-
11273)
CERTiflCATE OF COMPLI ANCE c, g 7, for Radio.ctive Materials Pac h,ses 1.f al Ceciif us e Num!.e, 1.lb f ne ss;on No.
1.tc) P,ck ar,e f dentific ation No.
1.id) Pages No. 1.lel Total No. Pages 9033 3
USA /9033/B( )
1 2
- 2. PP[ AMBLE lla)
This cen;riate is issued to satisf y c.e c,;o n s 173 393a 173 394,173.395. and 173 396 of the Depenment of Ts.mmisiion Ha:a'dnus Vat e,ials Regulations (49 CF R 1701P9 and 14 CF R 103) and sections 14 6 10a nd 14 0 100 of the Depariment of Ts antruristion orn9erous Co#90es Re<julations (46 CF R 146-149), as amendnf.
2 !b)
Th e re b,9;ng,nd cronie nt s desoibed in it em s treloa. rnecis t he saf eiy st and.e d s set fonh in Subpen C of Title 10. Code of I kiera? Repu!aiions, Part 71,
- Tech,9.ng of AM.cactive Maic,ials f or Te anspon,oc T e enst=an aDon of Red'DacHve I'-a'e'iat Und er C co a.n Cond i.ons.
2 It)
Tnes tenir.uit does nos r el eve the cons.goor f rom c omphann vvnh any e cq u o r me nt of the a r pulations of the U S. Depan mer t of T r am;.n ai.on or ot ne.r appl.c abie e rr oisiory e9encies, includ.ng t he gewee nment of an y counity through or into wh c.h the fack age w.ll be ir ar non ed.
- ~ - -
3 This tenifiuie n inu.1 on the t;esis of a sciy or,alysis,cpon of the p ckye c'es;on ce a pplic a no rr-3 (a)
Fe r;.ad by (N.mc.n d a ddr e ss).
3 (b)
T atie and ideqid nation of e epon o, am.:iuison:
Technical Operations, Inc.
Technical Operations, Inc. application fio r t.hwe s t Industrial Park dated November 8, 1974.
Bu rl i ng t on,
".a s sachu s e t t s 01803 3 cci o<.a ei No. 71-9033 4 C ONDal SONS 8*
T hi, c e r t.'.ui e n t or=1.i.o nel o pu n t he f ulf elbng o f t he e :;u'..e n e nis o f Subo.n o of 10 CF H 71, as app:.r able. and t he cor61kons ske c. bed in n. m t n,io.
D eu..gi.on of P, L eg.np ard A ut hor u e(1 Cont ent s. Mod el N u;nbar, F os.te Class. Oiher rond tions..nd R ef ei e nces' s
(a)
Packdging (1) 11odel Nos. :
660 and 660E c
(2) Description-A steel enc a sed, u ranium 'sh i el ded Gam:r.a Ray rjector.
Primary components consist of an outer steel shell, polyurethane potting material, uranium shield, Zircalloy or Ti tanium "S" tube, and end plugs.
The contents dre securely positioned in the "S" tube by a source cable locking device and shipping plug.
Tamper-proof seals are provided on the pdckaging.
The maximum total weight of the package is approximately 48 pounds.
(3)
Drawings The packaging is constrt,cted in accordance with the Technical 0,5 e r a t i o n s, Inc. Drawings I;os. 66025, Rev. A, Sheets 1, 2, and 3.
[
i
.'s s
/
'l l w
o s
g s
e
r 71-9033 Fagt T.
- C'ertificate fio. 9033 - Revision !!o. 3 - Docket rio.
s rs (R('
i
( b)
Contents s.
(1)
Type and form of material i
Iridium-192 sources which meet the requirements of special form as j
defined in 571.4(o) of 10 CFR Part 71.
1 (2)
Maximum quantity of material per package j
120 curies The source essembly for use with this packaging is limited to Teclinica'i 0!, era-f;.
tions, Inc. Model No. A424-9 as shown in Technical Operations, Inc. Drawing No.
C42400, Sheet 2 of 3, Rev. F.
7.
The r.ame plate shall be fabricated of r.aterials capable of resisting the fire test of 10 CFR Part 71 and maintaining their legibility.
The package authorized by this certificate is hereby approved for use under S.
general license provisions of Paragraph 71.12(b) of 10 CFR Part 71.
9.
Expiration date:
July 31, ],984.
m REFERENCES Technical Operations, Inc. application dated November 8,1974.
l Supplements dated:
December 15, 1978 and June 15, 1979.
FOR THE U.S. NUCLEAR REGULATORY COMMISSION O
gj]%'
/
Charles E. MacDonald, Chief Tr ansporta tion Certi fication Branch Division of Fuel Cycle and Ma terial sa f ety JUL 2 51979
.,a t e :
u
.. - - - - - =.
14 0/,j
. _~'!_ j
= = ~y
-A 6.w19] 5(E 54tf l er
__ _ ; 7 g-L pt.*
LOCKir)3 RN(REF)
O
('
5 :)
c]et SOURCE ASSEMBLY f
-.y/2///X+s
\\n( gLC&JNG P!N REF
.312') EM PALL j
F' m((F 9///
I I
'x2 i
/
o f>
.it-
',y y
.N
~
..@.. )
t
/
mi I
- e 2
- f w.d.
g.EEN RNS SLEEVE s
r, ww n-REF.]
s d._
M d('!M: ^g 'j -
2 j REF p.
d i T ~ -- '
LOCKED RT) MON
~I
?,,
r v c m,
$.li
'/ 3 4. R, s
x',(x r
s SEE V
V
///'
SEPAPATE wet 6
{
7 qf.._..(----
/
'l SELECTOR RitG ( REF.)
V
(- -
y a-SELECTOR BODY (REF.)
_UNLOC4D Ryj\\ TION SECTION B-B
~~'
- hJ[
T40TED EE a
~~
1.2g,,,,.fT-T=" --
SHIPPING CONTAINER df2/
- 'N DESCRIPTIVE ASSEMBLY.
t
- a i
c 66c25 A
m s
.<-. 2 :,
i s-.. 3-3
r- --
WM-J lA k,.ny 4 6 or M.
~
-STORAGE TUeE DEPLETED UtdNIUM RADIOCTIVE END PLATES RECEPTACLE SHIELD (% LB3)
SOURCE 11 GA. (.120)
I-20 FLAT HD SCREWS (0)
(lN STORE 6 POSITION)
COLD ROLLED STEEL 4
STEEL-CADMlUM PLATED
-CAST HANDLE r*lO ')2 FLAT HD SCREWS (q,
o
( ALUM. ALLOY)
STEEL-CADMW PLATED.;
d
~
a g
b@
N i
/
/
i
-TITANIUU OR ZlRCALLOY l LOCK ASSY
^
f
'SHELL
( EE M 2) s TUBE!4670.D. v ')85 LD.
j (060 COLD ROLLED STEEL)
( CAST IriSHIELD)
NAMEPLATE (2)-
s (5 DEL) 3 f
=r
._.m I
RE.
//
F
.p.
,)__
_\\
/
/
/ T'
\\/(
u Gm
\\
//i
/
/
dl
\\
4
/
/
/
f 6) i l
d Ol J
\\
[
li
/
SEAL CONTROL CONNECTCR- /
eWIRE V
ASSY
/
lO G
N (SEE5tm2O)
SASH -
-. w CHA\\M 8
y I
H
,.-a xy ir
/
l
/
\\
es>Ih
@o DAN GER ep";)
SOURCE IDENTd c-
/-
/
/ / -//
/\\t
/ib LABEL U "'
//
/
/ //
x
/ c5
___ (
I REF.
BOLT COER, RIVETED g
=
/-i--STORAGE PLUG
/
8
(.05G stain. ST)
-. CONNECTOR
/
7 REF.
5 l
12 3
4
'.[
CONNECTING RODS (4)
~~'
Norto et2 4 0 ~ M~ L-
~
~ ~"**' ~ *~
12Ll4 STEEL RIGlD
/
.a STORAGE PLUG ASSY PCLYURETHANE MODEL 660 GAMMA RAY PROJECTOR REihrCECEMENT FOAM E"SGMa =
SHiPPit6 CONTAINER SLEEVES (TITAN!UM OR ZlRCAll0Y)
[dk"iTN E
- .N DESLRIPTIVE ASSEMBLY
/ CAST IN SHIELD)
TOTAL WEIGHT 48 LBS
,,.. ' \\
C 66025 A
N
-. i,i mm o o.,