ML20006F203
| ML20006F203 | |
| Person / Time | |
|---|---|
| Site: | North Anna |
| Issue date: | 12/31/1989 |
| From: | Dreyer E, Peters T, Stafford A VIRGINIA POWER (VIRGINIA ELECTRIC & POWER CO.) |
| To: | Office of Nuclear Reactor Regulation |
| References | |
| 90-069, 90-69, NUDOCS 9002270256 | |
| Download: ML20006F203 (5) | |
Text
_.
7.
.(.
i VinotNix EI.ECTHIC AND POWER COMI'ANY j
Ricnxoxn,Vinatxtr unen February 20, 1990 i
Director, Office of Nuclear Regulatory Research Serial No.90-069 i
United States Nuclear Regulatory Commission NURMN:jm]
Washington, D.C. 20555 Docket Nos.
50 338 50 339 License Nos. NPF 4 NPF 7 Gentlemen:
l VIRGINIA ELECTRIC AND POWER COMPANY NORTH ANNA POWER STATION UNITS 1 AND 2 ANNUAL WHOLE BODY EXPOSURE REPORT Attached please find the subject repon for Nonh Anna Power Station for the period of January 1,1989 through December 31,1989. This report is submitted in accordance I
with 10 CFR 20.407(a)(2) and Technical Specifications Section 6.9.1.5.
Very truly yours, m
W. L. keb l
Senior Vice President Nuclear l
Attachment cc:
United States Nuclear Regulatory Commission Region ll 101 Marietta Street, N.W.
- Suite 2900 Atlanta, GA 30323 P
U.S. Nuclear Regulatory Commission Attn: Document Control Desk Washington, D.C. 20555 Mr. J. L. Caldwell l
NRC Senior Resident inspector North Anna Power Station bO b38
.. R PDC N
W.
~
.s
.c
. P; e
f i
P.
r i.
t RECORDED ANNUAL WHOLE BODY EXPOSURE REPORT
(
FOR THE
[
[
NORTH ANNA POWER STATION FOR THE PERIOD i
i JANUARY 1, 1989 - DECEMBER 31, 1989 L
i Prepared By:
[
//[.
T. G. Fsters '" ~ "
Supervisor Health Physics (Exposure Control) l Reviewed By:
i E. W. Dreyer l
Supervisor Health Physics (Technical Services) l P
Reviewed By:
/M M
A. H. Stafford Superintendent H alth Physics Approved By:
G. E. Xane Station Manager 8
m g.,
FORWARD THIS REPORT IS SUBMITTED AS REQUIRED BY TECHNICAL SPECIFICATIONS 6.9.1.4 AND 6.9.1.5 FOR NORTH ANNA POWER STATION UNITS 1 AND 2 AND 10 CFR PART 20 SEC. 20.407 (a) (2).
l
hpc o
94
-VIRGINIA POWER r-o;i i
' ~.
NORTH ANNA POWER STATION b
s LICENSE NOS. NPF-04 AND NPF-07 p
RECORDED ANNUAL WHOLE BODY EXPOSURES y
CALENDAR YEAR 1989
' Dose: Range.
Numb'er of; (mrem)
Individuals.
No measureable exposure 1,235 1
- 99-1,308 100 - 249.
256' j
- 250 - 499 309 l
500 - 749 239 750 - 999.
'166 b
1000 - 1999 450 2000 - 2999 114
-3000 - 3999, 16 4000'24999 3
5000 - 5999 0
6000 - 6999 0
i
. 7000.- 7999.
0 8000 - 8999-0
. 9000 - 9999 0
t b
10000' 10999 0
l 11000 zl1999 0
}
~ 12000 0-Total number of individuals reported 4,096 Total Station' Man-Rem as determined by TLD 1,471.227 The above.information is-submitted for the total number of individuals for
- whom: individual monitoring was provided during this calendar year.
i
. i.,
f
VIRGINIA POWER
~'
NORTH ANNA POWER STATION - LICENSE NOS. NPF-04 AND NPF-07 MAN-REM EXPOSURE-WORK JOB FUNCTION JANUARY - DECEMBER 1989 NUMBER OF PERSONNEL TOTAL MAN-REM WORK AND JOB FUNCTION Station Utility Contract Station Utility Contract Empioyees Empioyees Employees Employees Employees Empioyees Reactor Operations and Surveillance 150 1
58 37.972 0.041 1.184 Maintenance Personnel 19 0
30 1.431 0.000 0.227 Operating Personnel 78 0
2 33.130 0.000 0.012 Health Physics Personnel 35 0
24 2.298 0.000 0.939 Supervisory Personnel 16 0
0 1.093 0.000 0.000 Engineering Personnel 2
1 2
0.020 0.041 0.006 Routine Maintenance 645 94 1532 243.791 30.694 515.377 Maintenance Personnel 211 41 1083 159.410 27.857 342.744 Operating Personnel 227 3
19 28.318 0.094 2.413 Health Physics Personnel 71
.10 359 40.127 1.751 159.140 Supervisory Personnel 71 7
11 9.511 0.076 2.696 Engineering Personnel 65 33 60 6.425 0.916 8.384 Inservice Inspection 80 6
252 6.803 1.690 114.440 Maintenance Personnel 28 5
120 2.270 1.690 100.039 Operating Personnel 30 0
2 4.054 0.000 0.030 Health Physics Personnel 6
0 123 0.082 0.000 13.117 Supervisory Personnel 1
0 3
0.002 0.000 1.065 Engineering Personnel 15 0
4 0.395 0.000 0.189 Special Maintenance 71 15 1021 3.603 0.388 590.434 Maintenance Personnel 12 1
797 0.243 0.058 535.910 Operating Personnel 13 2
11 0.855 0.056 0.286 Health Physics Personnel 18 0
186 0.714 0.000 42.361 Supervisory Personnel 8
1 1
0.213 0.044 2.550 Engineering Personnel 20 11 26 1.578 0.230 9.327 Waste Processing 105 1
45 8.265 0.010 0.976 Maintenance Personnel 27 1
14 0.378 0.010 0.509 Operating Personnel 54 0
0 4.445 0.000 0.000 Health Physics Personnel 19 0
31 2.786 0.000 0.467 Supervisory Personnel 5
0 0
0.656 0.000 0.000 l
Engineering Personnel 0
0 0
0.000 0.000 0.000 l
Refueling 101 11 328 7.498 1.437 50.352 l
Maintenance Personnel 37 3
201 5.168 1.153 44.452 l
Operating Personnel 25 2
0 0.718 0.072 0.000 ifealth Physics Personnel 20 0
121 0.517 0.000 5.237 Supervisory Personnel 18 1
1 1.091 0.030 0.031 Engineering Personnel 1
5 5
0.004 0.182 0.632
-~
-