ML20006E905

From kanterella
Jump to navigation Jump to search
Monthly Operating Rept for Jan 1990 for Joseph M Farley Nuclear Plant,Unit 2
ML20006E905
Person / Time
Site: Farley 
Issue date: 01/31/1990
From: Hairston W, Dennis Morey
ALABAMA POWER CO.
To:
NRC OFFICE OF INFORMATION RESOURCES MANAGEMENT (IRM)
References
NUDOCS 9002260519
Download: ML20006E905 (5)


Text

iy ~

i ' ) ' 'e n

Alabama Power Company 40 lnverness Center Parkway j

Post Office Box 1295 Birmingham, Alabama 35201 Telephone 205 868 5501 W. G. Hairston,111 Senior Vice President i

Nuclear Operations AlabamaPbwer r

the southem electre system f

February 15, 1990

.i

/

Docket No. 50-364 p

i I

j' U. S. Nuclear Regulatory Commission ATIN: Document Control Desk l

L washington, D. c.

20555 Joseph M. Farley Nuclear Plant

~;

Unit 2 Monthly Operating Data Report I

A Attached is the January 1990 tionthly Operating Report for Joseph M. Farley t&telear Plant Unit 2, required by Section 6.9.1.10 of the Technical Specifim tions.

If you have any questions, please advise.

j Respectfully submitted, f

g

'I GC a ston, II JGS sme/1.6 Attachment cca Mr. S. D. Ebneter Mr. E. A. Reeves Mr. G. F. Maxwell 1

i 1

F 9002260519 900131 gDR ADOCK 05000364 PNU V

t; '

n OrtswrIN3 InTh REFORT DOCKET NO.

50-364 IWit 2/2/90 CCMP1Jr!M) BY D. N. Morey

'IEEEPHCEE (205)899-5156 OPERETING S1RIUS Notes

1. Unit Names Joseph M. rarley - Unit 2
2. Reporting Period:

January, 1990

1) Cumulative data since
3. Licensed Thermal Power (fMt):

2,652 7-30-81, date of

4. Nameplate Rating (Gross MNe):

860 commercial operation

5. Design Electrical Rating (Net fMe): 829
6. Maxinum Dependable Capacity (Gross MNe):

868.6

7. Maxinum Dependable Capacity (Net MWe):

828.2

8. If Changes Occur in Capacity Ratings (Items Number 3 Through 7) Since Last Report, Give Reasons:

Items #6 and 47 have been changed due to evaluation of operating experience.

9. Power Level 1b Which Restricted, If Any (Net MWe):

N/A

10. Reasons For Restrictions, If Any:

N/A

=

'Ihis Month Yr-to-Date Cumlative j

t

11. Hours In Reporting Period 744 744 74 553
12. Number Of Hours Reactor Was Critical 744.0 744.0~

~5

.T'

13. Reactor Reserve Shutdown Ilours 0.0 0.0 35T'
14. Hours Generator On-Lir.e 744 T

~744.0 63,816.0

15. Unit Reserve Shutdown Hours 0.0 0.0 0.0
16. Gross '1hermal Energy Generated (IMI)

I~?I70,306 1,970,306 152,226,573 654,930 E, 21,172

~

17. Gross Electrical Energy Generated (MNH) 654,930

~ 624,764 P, 66,154

18. Net Electrical Energy Generated (PMI) 624,764
19. Unit Service Factor 100.0

'100.0 85.6

20. Unit Availability Factor 100.0 100.0 85.6

~

21. Unit Capacity Factor (Using MDC Net) 101.4 101.4 82.9 22L Unit Capacity Factor (Using DER Net) 101.3 101.3 81.8
23. Unit Forced Outage Rate 0.0 0.0 4.5
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: N/A
26. Units In Test Status (Prior to Comercial Operation):

Forecast Achieved INITIAL CRITICALITY 05/06/81 05/08/81 INITIAL ELECTRICITY 05/24/81_

05/25/81 C0fGEERCIAL OPERATICM 08/01/81 07/30/81

(

rorm 2/30 1

ymwy r

,7 4

4 c r.m w

"+-

p

- c s,

+

' JOSEFH M. ' FARLEY NUCLEAR ILWT LNIT 2 NAHRATIVE SitHARY OF OPERATIONS January, 1990 E'

hm were no unit shutdowns or signifloant power reductions during the O

~ month of January.

c.

N following major safety-related r.aintenatee was perfonned in the month I

of January:-

f e

,1.

A water leak was repaimd ard a new coolirW ' coil was installed on the -

p-

+

' 2A~ service water pianp motor.

u te 2.. 'Ihe turbine driven auxiliary feedwater pump overspeed tappett assembly was mplaced.

p p

3.- The 2A incore detector ard clutch were mplaced.

p f.'

4.

Miscelleneaus corrmet.ive ard rWventive mairatetunce was perfonned on -

T, L

the diea#1 r eerators.

I!'

g p.

Lfr Ll:

Til 1

n re

_rw' m

L'

(

1

~ - _.

t

^

r t

DOCKET No.

50-364 UNIT 2

MTE rebruary 2,1990 t

CCMPLETED BY D. N. Morey TELEPHONE (205)899-5156 I

MONDI January MY AVERAGE MILY POWER LEVEL Mt AVERAGE MILY MMER LEVEL (le9e-Net)

(IMe-Net) t-1 845 17 836 2

845 18 838 3

842 19 835 4

839 20 833 5

839 21 838 6

840 22 843 7

840 23 842 s '

8 843 24 837 9

027 25 835 1

10 816 26 846 11 842 27 845 12 845 28 841 13 846 29 839 14 845 30 845 15 843 31 845 16 839 1

INSTRUCTIONS on this format, list the average daily unit power level in MWe-Net for each day in the reporting month. Compute to the nearest whole megawatt.

. Form 13/21

-r-.

.;[ h UNIT SEUTDotfFS JWrD roWEm mEDUCrloWS DoCERT Wo.54-364 IC UWtr WhfE J. M. FaRLEr

'JWIT 2 _/.

DkrE FESSWhar 2, 19*9 comEno n

o. w. - Er erront n ye sanoami rEzarnosE (mesi m -s154 l

l l

l l

l MErWoD OF

-l LICENSEE l

l CaWSE & CORmECrIVE.

l I

I I

I numeros 1 i Snverras i EvEnr i Srn.m I u m I

actron to

(

ino.

I narE I rrrE.I <noemS)

I =EaSon I no== mEacrom' I mEroar e !cooE' !em i

reEv m mEcumet cE I

.i 2

5 i

l 1

1 I

I i

.I I

I I

lenEmE wEmE no owir Sauroo S om Szo rrreant co En mEnverro S ovarma.r=E Mourn oe annuaar.

1 IL I

I I

I I

I i

1 l

i I

I I

I I

-I i

i i

I I

I I

I I

I I

I i

I i

l-1 I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

i i

I I

I I

I I

I I

I I

I I

I I

I I

l~

l l

I I

I I

I I

I I

I I

I I

I I

i i

i l

I i

I i

l i

I i

i i

i i

i i

l i

l l

I I

I I

I I

I I

I I

I i

i i

i I

I I

I I

I I

I i

.I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

I I

i i

i i

l I

I I

I I

I I

I I

I I

I I

i l

I i

l I

I i

i i

i l

I i

i I

I i

i i

i i

i l

l I

I I

i i

i i

l I

i I F: Forced Reasons Meth63*

Exhibit G-Instructions-S: Scheduled a-Equipment Failure (Explain) 1-Manual for preparation of Data B-Maintenance or Test 2-Manni Scran, Entry Sheets for Licensee C-Refueling 3-autoestic Scree.

Event neport(LEm) File (NUmEG-D-Regulatory mestriction 4-other *Explaine 0161)

E-operator Training s License Examination F-administrative

' Exhibit ! -Same Source G-operational Error (Explain)

(9/77) n-other (Explaint M Rxa M

-