ML20006C440

From kanterella
Jump to navigation Jump to search
Discusses ACNW 16th Meeting on 900124-25 Re NRC Program on Low Level Radwastes
ML20006C440
Person / Time
Issue date: 01/30/1990
From: Moeller D
NRC ADVISORY COMMITTEE ON NUCLEAR WASTE (ACNW)
To: Carr K
NRC COMMISSION (OCM)
References
NACNUCLE-R-0032, NACNUCLE-R-32, NUDOCS 9002080043
Download: ML20006C440 (2)


Text

E n y.1 n

l L

..r;%

. !pt,

'o UNITED STATES gg y

L I

NUCLEAR REGULATORY COMMISSION i

r

,g ADVISORY COMMITTEE ON NUCLEAR WASTE

]

l WASHINGTON. D.C. 20tW January 30, 1990 I

)

The Honorable Kenneth M. Carr Chairman

)

U.S. Nuclear Regulatory Commission Washington, D.C. 20555

)

Dear Chairman Carr SUBJECT NRC PROGRAM ON LOW-LEVEL RADIOACTIVE WASTES During-its 16th meeting, January 24-25,

.1990, the Advisory l

Committee on Nuclear Waste met with representatives of the Division of Low-Level Waste Management and Decommissioning for a review of matters'partaining to the production, treatment, and disposal of i;

inw-level, radioactive vastes (LLWs).-

These matters had also been j

discussed with other 3 embers of the NRC staff on several previous L

occasions.-

As. a result of these reviews, va offer the following

?

comments.

j

(

\\

1.

While considerable attention han been given to the l

_ development of requirements for the siting, construction, l

and' operation of disposal facilities, there appears to be a~1ack of coordination of these activities with the l

processes that produce the wastes. It is these processes I

which, in ' turn, determine the chemical and - physical p

characteristics, radionuclide content, and volumes of the wastes.

In. our opinion, these processes and the-

?

resulting products may have - as, much bearing on the protection - of public health and safety as do the.

requirements for the disposal facilities.

We believe this is an excellent example where a systems approach could yield dividends.

Before this can be accomplished, however, there is a need for closer coordination of L

relevant activities by NMSS, NRR, and RES.

i 2.

Under the requirements of the Low-Level Radioactive Waste-l Policy Act and amendments, a number of states and state compacts are moving forward to develop plans for the siting 1and construction of low-level-radioactive waste disposal facilities. Although the NRC staff has prepared a multitude of reports containing information that would L

be useful to the Agreement States and LLW facility l-developers, there is currently no single document L

containing comprehensive guidance or a "Ioad map" to n

gJgs2o2oR@nfas$e R

o L

Td

i

....*r a ~

I The Honorable Kenneth M. Carr 2

January 30, 1990 i

5 reports that pertain to this topic.

To correct this situation, we recommend that a guidance document contain-ing a summary of relevant laws and key regulations, i

regulatory guides, NUREG documents, and technical posi-

tions, suitably annotated and cross-referenced, be prepared.

To the extent practical, pertinent standards developed by the U.S. Environmental Protection Agency and applicable key documents developed by the U.S. Department of Energy might also be cited in this report.

3.

The Committee continues to believe that a need exists for i

a system through which the benefits of operating ex-t parience can be factored into NRC activities related to the generation and disposal of LLW.

One contribution to this subject would be the preparation of a report based on a definitive review and digest of the experience gained at the Maxey Flats, Sheffield, and West Valley disposal facilities, j

i 4.

The Committee is concerned about the availability of adequate disposal capacity, licensed under the provisions of 10 CFR 61, Licensing Requirements for Land Disposal of Radioactive Waste, to accommodate LLWs after the scheduled closure in 1992 of the currently operated l

Barnwell, South Carolina, and Beatty, Nevada, disposal facilities.

We urge that the Commission increase its efforts to encourage the States to accelerate the process -

for developing suitable disposal facilities.

We hope these comments will be helpful.

Sincerely,

,q Dade W. Moeller Chairman l'

i i

..