g gy s7-TENNESSEE VALLEY' AUTHORITY CH ATTANOOGA. TENNESSEE 37401 SN 157B Lookout Place 9%j ;

u

'JAN 161990 n

O.S. Nuclear Regulatory Commission

. ATTN:

Document Control Desk Hashi.19 ton, D.C.

20555 Gentlemen:

In the Matter of

)

Docket Nos 50-259

(

Tenni:ssee Valley Authority

)

50-260 50-296 BROWNS FERRY NUCLEAR PLANT (BFN) - MONTHLY OPERATING REPORT FOR THE MONTH OF DECEMBER 1989 In accordance with the requirements of the BFN Technical Specifications (TS) section 6.9.1.3, TVA is submitting the Monthly Operating Report for the nonth 5

of December 1989.

If you have any questions, please telephone Patrick P. Carter, BFN, (205) 729-3570.

Very truly yours, TENNESSEE VALLEY AUTHORITY

')

Man'agem, Nuclear Q1 censing and Regulatory Affairs Enclosure cc (Enclosure):

INPO Records Center Mr. Ted Marston, Director Institute of Nuclear Power Operations Electric Power Research Institute 1100 Circle 75 Parkway Suite 1500 P.O. Box 10412 Atlanta. Georgia 30389 Palo Alto, California 94304 Regional Administration Mr. B. A. Wilson, Assistant Director U.S. Nuclear Regulatory Commission for Inspection Programs Office of Inspection and Enforcement TVA Projects Division Region II U.S. Nuclear Regulatory Commission 101 Marietta Street, NW, Suite 2900 Region II Atlanta, Georgia 30323 101 Marietta Street, NW, Suite 2900 Atlanta, Georgia 30323 Mr. B. D. Liaw, Director TVA Projects Division NRC Resident Inspector One White Flint,' North Browns Ferry Nuclear Plant 11555 Rockvllie Pike Route 12, Box 637 Rotkville, Maryland 20852 Athens, Alabama 35609 2000 9001220264 891231 DR ADOCK 0500 9

M/

se to., o,..,menx cm io,.,

cpf;,,rhmAg c,a ;,- T..

c.,/.1.

3 I,

5 a,.m ab, t,s s

.; w.

1-

.+-

.., p..;

., x,y. vy,

.cy-
.n to me r

w' % s ':. f,'

y.

x i

+

[ 9 ;'

l

/_4.

>jy,

.)

'ym.

3; 7-

/

MONTHLY OPERATING, REPORT.

.m

/N,,

BROWNS FERRY NUCLEAR PLANT-i m

'i,

'd2 f

,a.

I I

. i '_ -

s t

L'

- f

. 8' TENNESSEE. VALLEY AUTHORITY?

,1 i

G:/ /.

9 e '

x

+1

,.x DECEMBER.1989

,.?

1

/

tt(

gq -.

DOCKET-NUMBERS 50-259, 50-260; AND 50-296-LICENSE NUMBERS DPR-33, DPR-52,'AND DPR-68 s

6 k

m

'g5 l-1 i

,! ) ;.

) '..-

-'1

.G.

i i

e f

.m

'f,-r e

k, f

~';

s i

L M'

f

.q -

  1. 7 A

c s s

i I

g.

mg-

~ y m:

g e. n '

A,"

..t

is,

a

=

a 4

.s. g,

.i r

.g.

OPERATIONAL

SUMMARY

J DECEMBER 1989.

f

~

UNIT 1 i

r

.A' Unit remains'on administrative hold to resolve various'TVA-~and NRC concerns, o-

' UNIT 2' r

E

' Unit reniains-on administrative hold'to resolve various TVA and NRC concerns.

Modification; operation, and maintenance work continues to support restart.

,, y,..

a s

it' UNIT 3-y<

M iunit remilns ontAdministrative hold to resolve various TVA and NRC concerns.

fjr, i

2 ;:

';Q '

t

?

O;

)

4, 4

F o

9 s

s s.

s o

/

it.?[

y Irll ':

j'],.

.o 4

4,, P0; w' 'ci" a, O 1-m w

-- m

! t,'

~,

'(. ' g,} k '

y w;jo,1

'4 W%

' ", ;.':~ ' H.1 T.

AVERAGE DAILY UNIT 70NER LEVEL' L? g

/

DOCKET NO.

50-259 P

'w,

UNIT One

,i:

DATE.

01/09/90 J

COMPLETED BY S. A. Ratliff TELEPHONE (205) 729-2937-2 p

m.

.O e

+-,

E-

. MONTH DECEMBER 1989 i

,4

. DAY.

AVERAGE DAILY-P0ktR' LEVEL DAY AVERAGE DAILY POWER LEVEL'

._ MWe-Net)

(MWe-Net)

(

.1

-2 17

-2 ey

-i,,

2-

- 18

-2 g

3:

-2 19

-2

' 4'.

'3-20

-2

~

'1 51

-2 21

-3 i

v'.

22

-2

6'

-2 W

s

- 7 '- 23

-2 8 -'

2' 24

-1 9

'2 25

-I r.

=

g-.-?,

10.

-2 26~

-3

.p 11'

-2 27

-2 1

12

-2 28

-2

[

. -2 29

-2

y 4

.m.

t14

-2 30

-2 g,

15

-2 31

-2 M

L16:

-2

\\'

k

'l!

?,

)

Y-1_..

h;,

4 l 'I

_d'

=ut 4.-

i.

s

~

AVERAGE' DAILY UNIT POWER LEVEL DOCKET NO.

50-260 Unit Two 1'

DATE 01/09/90 COMPLETED BY S. A. Ratliff TELEPHONE (205) 729-2937 MONTH DECEMBER 1989 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MWe-Net) 1

-8 17

-9 2

-8 18

-8 3

-9 19

-8 4

-9 20

-8 5

-8 21

-9 6

-8 22

-8 7

-8 23-

-9

.8

-8 24

-7 9

-8 25

-7 10

-8 26

-10 11

-8 27

-18 12

-8 28

-7 13

-8 29

-7 14

-8 30

-7 15

-8 31

-7 16

-8

vv

.f u

AVERAGE DAILY UNIT POWER LEVEL DOCKET NO.

50-296 Unit Three DATE 01/09/90 COMPLETED BY S. A. Ratliff TELEPHONE (205) 729-2937 HONTH DECEMBER 1989 DAY AVERAGE DAILY POWER LEVEL DAY AVERAGE DAILY POWER LEVEL (MWe-Net)

(MHe-Net) 1

-3 17

-3 2

-3 18

-3 3

-3 19

-3 4

-3 20

-3 5'

-3 21

-3 6

-2 22

-3 7

-2 23

-3 8-

-3 24

-1 9 25

-7 10

-3 26

-4 11

-3 27

-4 12

-3 28

-3 13

-3 29

-3 14

-3 30

-3 15

-3 31

-3 16

-3 1

i

+4 OPERAllWG DATA REPORT DOCKET NO.

50-259 DATE _Decunber 1989 COMPLL100 BY $. A. Ratliff TELD' HONE (205) 729-2937 g'ERATING STATUS '-

! Notes 1.

Unit Name:

Browns ferry Unit One 5+

2.

Reporting Perlod:

December 1989 1

3.

Licensed thennel Power (Met):.3293 1

1 4.

Nameplate Rating (Cross Mee):,,l_152 1

1 5.

Design Electrical Rating (Wet Mie):.1065 6.

Maxlana Dependable Capacity (Gross Mee): 1098.4

7..Maulana Dependable Capacity.(Net Mee): 1065 t

i 8.

If Changes Occur in Capacity Ratings (Items Nunber 3 Through 7) $1nce Last Report, Clve Reasons:

N/A 9.

Power Level to Idhich Restricted, If Any (Net M4e):

N/A

10. Reasons for Restrictions, if Any:

N/A 1his Month Yr-to-Date Cumulative

11. Hours in Reporting Period 744 8760 161528
12. Ihauber of Hours Reactor idas Critical 0

0 59521

13. Reactor Reserve Shutdown Hours 0

0 6997

'14. Hours Generator On-l.ine 0

0 58267

-15. Unit Reserve Shutdown Hours 0

0 0

16. Gross thennel Energy Generated (MdH) 0 0

168066787

17. Gross Electrical Energy Generated (MI) 0 0

55398130

18. Het Electrical Energy Generated (MI)

-1445

-43337 53455394 l

19. Unit Service factor 0

0 36.1

20. Unit Availability Factor 0

0 36.1 l?

'21. Unit Capacity factor (Using MDC Net) 0 0

31.1 l-

~.22. Unit Capacity Iactor (Using DER Net) 0 0

31.1

23. Unit forced Outage Rate 100 100 59.2
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: To be detennlied 0277k/10 I

l o

k OPERAllNG DA1A REF9RT DOCKET NO.

50-260 DATE Decentier 1999 COMPLETED BY

5. A. Rat 11ff TELEPHONE (705) 729-2937 OPERAllNG STATUS

! Notes j.

[

1.

Unit Name: _ trowns Ferry Unit two

(

2.

heporting Period:

Decautier 1989 1

1

3. i Licensed thennel Power (PWt):.3293 1
4.. Meneplate Rating (Gross PWe): 1152 I

i L

5.

Design Llectrical Rating (Net IWe): 1065 1

i'-

6.

Maxinun Dependable capacity (Gross fWe): 1098.4

7.. Maxlanan Dependable capacity (Wet PWe): _1065 B.

If Changes Occur in Capacity katings (Items Wund>cr 31hrough 7) Since Last Report, Give Reasons:

N/A 9.

power Level to Which Restricted, If Any (Net PWe):

N/A

10. Reasons f or Restrictions, if Any:

N/A 1his Month Yr-to-Date Cumulative

11. Hours-in Reporting Period 744 8760 156415
12. Nisuber of Hours Reactor Was Critical 0

0 55960

13. Reactor Reserve Shutdown Hours 0

0 14200

14. Hours Generator On-Line 0

0 54338

15. Unit Reserve Shutdown Hours 0

0 0

16. Gross thennel Energy Generated (fWH) 0 0

153245167

17. Gross' Electrical Energy Generated (MI) 0 0

50771798

18. Het Electrical Energy Generated (MI)

-6243

-37881 49013851

19. Unit Service factor 0

0 34.7

.20. Unit Availability factor 0

0 34.7

'21. Unit' Capacity factor (Using MDC Net) 0 0

29.4

22. Unit Capac ty factor (Us ng DER Net) 0 0

29.4 i

i

23. Unit Forced Outage Rate 100 100 59.7
24. Shutdowns Scheduled Over Next 6 Months (Type, Date, and Duration of Each):

N/A l

l

25. If Shut Down At End Of Report Period, Estimated Date of Startup: Under Review 0277k/11

~

4 g

V-l b

i OPLRA11NG DATA REPOR1 F

DOCKET Wo.

50-296

(

I DATE December 1989 COMPT.E1ED BY

5. A. Ratliff TELEPHONE (205) 729-2937 i

i(

. OPERAVING STATUS

! Notes i

1.,Un)i Name:

Browns Ferry Unlt 1hree 2.

Reporting' Period:

December 1999 1

1 l'

3._ l.lcensed thermal Power (WL): 3293 I

4; Nameplate Rating (Gross % ): 1152 5.

Design Electrical Rating (Net me): 1065 1

1 L

6.

Maximum Dependable Capacity (Gross We): 1098.4 i

7.. Maximum Dependable Capactty (Wet me)t 1065-l 8.

If Changes Occur in Capacity Ratings (items Number 3 Through 7) Since Last Report, Give Reasons:

l N/A j

9.

Power Level 10 Which Restricted, If Any (Net We):

N/A

10. Reasons f or Restrictions, if Any:

N/A j

-J This Month Yr-to-Date Cumulative

11. Hours in Reporting Period 744 8460 138840
12. Number of Hours Reactor Was Critical 0

0 45306

13. Reactor Reserve Shutdown Hours 0

0 5150

-14.HoursGeneratorfhine 0

0 44195

15. Unit Reserve Shutdo m Hours 0

0 0

i

16. Gross thermal Energy Generated ( WH) 0 0

131868267 17.' Gross Electrical Energy Generated ( WH) 0 0

43473760

18. Net Electrical Energy Generated (1941)

-2173

-19724 41880363

19. Unit Service Factor 0

0 31.8 l

20. Unit Availability Factor 0

0 31.8

21. Unit Capacity Factor (Using NDC Net) 0 0

28.3

22. Unit Capacity factor (Using DER Net) 0 0

28.3

23. Unit Forced Outage Rate 100 100 63.8
24. Shutdowns Scheduled Over Next 6 Months (Type. Date, and Duration of Each):

N/A

25. If Shut Down At End Of Report Period, Estimated Date of Startup: To be determined L'

0277k/12 1

f V

A

L ;r <

s

.-,\\

4

~

30CKET ND:

MN "i0-tx u

1

. IMIT SwJTDOWIS'AMD POWER REDUCTIONS

" LMIT MAME?

Gem

+

DATE:

81/2/98 "l

REPORT MONTH: DerAr 1999 (9MPLETED SW S. A. Rattiff

^ !

1 TELEPHO'4E.;I205) 729 2937

3. f ~

r

! Method of.'

! Licensee-1 1-1 Caese and Corrective I

i

!' Duration !

! Shutting Down ! Event

- ! System

! Coopenent !

Action to-J* 1 ~

1 Report No...

!. Code *

! Code'

!- ' Prevent Recurrence

~

- 1. No.'

! Date

! Type'- - !~(Hours) ! Reason 12 Reactor 8-s-

l-m!,

! 315 : ! 06/01/85 !

F-

!! 745'

' F-4-

1 1

!~

! Administrative hold to !

1. resolve.various TVA and !

't-t

~ 1 i

! NRC concerns.

1 l-

! ~

!~

1'

' l I'

1

  • E hibit G Instrwctions

'F: Forced Reason:

' Method:

x S: Scheduled A-Equipmefit failere (Explain) 1-Manual for Preoaration of Data 2-Manual Scram Entry sheets for Licensee B-Maintenance or Test

' 3-Automatic Scram Event Report (LER) File C-Refueling-D-Regulatory Restriction 4-Continuation of Existing Outage (fA! REG-061) -

E-Operator Training and License Examination 5-Reduction F-Administrative 9-Other G-Operational Error (Explain)

' Exhibit I-Same Source H-Other (Explain) 0277k/13 T

+

+

89 TP-'

e Ww gp

't' f>v w' 8 fAw

  • y VWD-w'*
  1. e.,eM" ' '

gb-gr^v-e fG d'-

yegis -* M v

.'w 't r v+ M ew" (W

eme$w.-9

  • M V,-g g te g Nr

+w---

gmyvgy-*-tw-v W

wu y

g-tir v ' N" ' "

w'

-W

=

r-

~,.

. ;., n

.. ~ " ~'

1

7 (JNIT SHiJTDOWNS AMio PSER REDIKTIO45 c-'

~ q tm!T M.

- Tem

J +);.=

l'.

.s a'

~

DSCIET W: ' "*-*"*

~

4

~ _ ~

~

1OATE' 81/2/98

' '39

..* - 1989 '

COMPLETED BY:$- A. natitff.

3.7_.

9 REPORT NONTH! h

- -. TELEPHONE!.(2951 69-2937 X /~

~

-.?

~-

~

h 1

! Nethod of:.4.. ! Licensee -

s!.

--1-: Cause and Corrective ;!.

E !..

1:

! Duration !.

!Shetting Down' ! Event-- '. ! System-

! Component 11 Action to 4-t' l

- ! No'.

1! : Da t e..

! Type'

! (Hours)..! Peason'

-!' Reactor'

'! Report Wo.

!. Code *

!' Code

Prevent Recorrence 1

'!~

I'

!c 2 !'

't

! Administrative hold to

-! 305' :! 09/15/84 !.

F.

'!' 745 F -

?4-

!!. resolve various TVA and !'

~!-

s! ' ' -

! NRC concerns.-

E!

1 1

1

~

1 1-

~!

i' 1

f,

~

~!

2

!~

!~

1 1'

?

!~

1'

'F: forced

' Reason:

Mtthod:.

  • Exhibit G-Instructions

~8 5: Scheduled A-Equippent failure (Explain) 7-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File D-Recalatory Restriction-4-Continuation of Existing Ovtage

' (NUREC41)

E-Operator Training and License Examination -

5-Reduction F-Administrative 9dt.ber

'Ex'ibit I-Same Source n

G-Operational Error (Explain)

M-Other (Emplai.1) 0277k/14 P

-DTT'

't T'M.rtr-3

- aw -

yygg.,

7

p:,,-

4

?

r

,3.._.

,n 2

e 3

y-J.)IT SHUTD0wtS AND POWER REDUCTIONS -

tMIT NR80 Thres E

~

-T 17,.i Q

.r.

s DATEi 01/2/98-REPORT MONTH; Du

  • r 1989'

~

! COMPLETED BYrS. A. Ratiiff

'. :~

- TELEPHONE:(295) 729 BF Cause and Corrective

.! Method of.

.! Licensee

! Duration ! :

! Shutting Down ;! Event-

. ! System. - ! Co*ponent !L-

- Action to

- ! No.

!T Date

! Type * ' ! (Hours) ! Reason'

! Reactor

! Report No..'! Code

  • 1 Code' Prevent Recurrence 8

t

-1 1! -

,1-1

F 4

1-l!

! Administrative hold to !

! 157 1 03/03/85 !

F

! 745 I'

! resoTve various TVA and !

! NRC concerns.

1

. !=

~ !

n!

.r t

t

~ !

1 I

i

' t T: Forced

. Reason:

' Method:

  • Exhibit G-Instructions 5: Scheduled A-Eq? pment Failure (Explain)

. 1-Manual for Preparation of Data B-Maintenance or Test 2-Manual Scram Entry sheets for Licensee C-Refueling 3-Automatic Scram Event Report (LER) File -

D~ Regulatory Restriction 4-Continuation of Existing Outage (NUREG-061)

E-Operator Training and License Examination-5-Reduction F-Administrative 9-Other S

G-Operational Error (Explain)

Exhibit I-Same Source H-Other (Explain) 0277k/15 s'

-.r.Wy gN g

,y g-9.py,9 p-9gf y..g_.m q,.i_.ewyy,pg 9g-

.'y y9q>. -

9y9 p.-g..

.yg.

94 4.

p, ysyp g

,*-emqy g,,c.y g y y-_9

,y 9

y

..9-yawy 3 4

-.,g,.

q q

p,