We Or e
g u, E,,,. ; [g UMTED $TATES t>
q NUCLEAR REGULATORY COMMISSION 5
[
WA$HINGTON D. C. 20$$5 a
DEC 2 B GB9
?p.
,4 MEMORANDUM FOR:.
Charles E. Rossi, Director AEOD/E910 Division of Operational Events Assessment Office of Nuclear Reactor Regulation l
FROM:-
Thomas M. Novak, Director Division of Safety Programs Office for Analysis and Evaluation of Operational Data v
SUBJECT:
POTENTIAL FOR GAS BINDING OF HIGH HEAD SAFETY INJECTION PUMPS RESULTING FROM INSERVICE TESTING OF VCT OUTLET ISOLATION VALVES Enclosed is an Engineering Evaluation report concerning the potential to gas bind both high head safety injection pumps as a result of inservice testing of voluwee 1
control tank outlet isolation valves.
During inservice testing at the Trojan nuclear plant, plant personnel discovered that the procedurally specified opening of one manual " bypass" valve around the motor operated VCT outlet isolation valves could render both high head safety injection pumps inoperable if a safety injection signal occurred while testing was in process.
Furthermore, upon completion of testing, should the manual bypass valve be inadvertently left in the open position, both trains of high head safety injection could be unknowingly rendered inoperable for an extended period of time.
NRC Information Notice (IN) 88-23 was previously issued to address gas binding of high head safety injection pumps due to dissolution of hydrogen in low pressure portions of ECCS piping.
Supplement I to IN 88-23 later described additional problems at the South Texas, North Anna, and Surry plants involving air in the suction piping of centrifugal charging pumps.
'The enclosed proposed supplement to IN 88-23 informs licensees of the previously mentioned, newly recognized potential for gas binding the high head safety injection pumps by opening a bypass valve around the VCT outlet isolation valves.
DFo}
9001100171 0912Ae i
)'
[
DR ADOCK OSOOg 4 ll NRC RLE CENTER COPY g
j
I
.g.
t L
lt is recommended that the enclosed proposed supplement to NRC Information Notice
'No. 88-23 be sent to all PWR licensees and construction permittees to alert them to the potential for gas binding the high head safety injection pumps as a result of t
testing activities.
For further information regarding this study, please contact Mark Padovan (x24445) of my staff.
/p/
Thomas M. Novak, Director Division of Safety Programs Office for the Analysis and Evaluation of Operational Data
Enclosures:
As stated Distribution:
PDR KBlack i
TNovak MMendonca, Region V ROAB R/F BBrady VBenaroya MTaylor, EDO DSP R/F Central File JRosenthal EJordan MPadovan CHaughney 1
-Plam l
CHeltemes l
LSpessard HFaulkner FiL W
W R@B:DSP: AE0D R02:DSP:AE00 DSP:AE00 0
@ROAB:DSP:AE0D lPadovan:mp Plam JRosenthal VBenaroya Ti 12/.%/89 12/r///89 12/27/89 12/t7/89 89 l