ML20005E565
| ML20005E565 | |
| Person / Time | |
|---|---|
| Site: | Armed Forces Radiobiology Research Institute |
| Issue date: | 12/22/1989 |
| From: | Eselgroth P NRC OFFICE OF INSPECTION & ENFORCEMENT (IE REGION I) |
| To: | Irving G ARMED FORCES RADIOBIOLOGICAL RESEARCH INSTITUTE |
| References | |
| NUDOCS 9001080146 | |
| Download: ML20005E565 (12) | |
Text
,
i.
L 1
Docket No: 50-170 Defense Nuclear Agency Armed Forces Radiobiology Research Institute L
ATIN: Colonel George Irving, III, MC, USAF L
Director F
Bethesda, Maryland 20814-5145 Gentlemen:
SUBJECT:
SENIOR REACTOR OPERATOR LICENSING EXAMINATIONS In a telephone conversation between Mr. M. Moore, Reactor facility Director and Mr. B. Hughes, Operations Engineer, arrangements were made fo-the administration of licensing examinations at the Armed Forces Radiology Research Institute, i
The written examinations are scheduled for March 5,1990. The operating examinations are scheduled for March 6-8, 1990.
To meet the above schedule.-it will be necessary for you to furnish the refer-ence material listed in Enclosure 1, " Reference Material Requirements for
- Senior Reactor Operator Licensing Examinations," by January 29, 1990. Any
. delay in receiving approved, properly bound and indexed reference inaterial, or the submittal of inadequate-or incomplete reference material may result in the examination being rescheduled. Mr. M. Moore has been advised of our reference
' material requirements, and the address where each set is to be mailed.
You are responsible for providing adequate space and-accommodations for ad-ini-stration of the written examinations., " Requirements for Admini-
+
stration of Written Examination," describes our requirements for conducting these examinations.
- contains the Rules and Guidelines that will be in effect during the administration of the written examination. The facility management is respons-ible for ensuring that' all applicants are aware of these rules.
The facility staff review of the written examination will be conducted in accordance with requirements specified in Enclosure 4, " Requirements for Facility Review of Written Examinations."
All completed license applications should be submitted at least 30 days before the first examination dates so that we will be able to review the training and i
l.
C 9001080146 891222 PDR ADOCK 05000170 V
PDC 0FFICIAL RECORD COPY HUGHES/AFRRI 90-DAY /12/12/89 -
0001.0.0 12/15/89 h7
Defense Nuclear Agency 2
experience of the candidates, process the medical certifications, and prepare i
final examiner assignments after applicant eligibility has been determined.
If L
the applications are not received at least 30 days before the examination dates, it is likely that a postponement will be necessary.
Mr. M. Moore has been informed of the above requirements.
This request is covered by Office of Management and Budget Clearance Number 3150-0101 which expires May 31, 1992. The estiraated average burden is 7.7 hours8.101852e-5 days <br />0.00194 hours <br />1.157407e-5 weeks <br />2.6635e-6 months <br /> per response, including gathering, xeroxing and mailing the required material.
Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to the Records and Reports Management Branch, Division of Information Support Services, Office of Information Resources Management, U.S. Nuclear Regulatory Commission, Washington, D. C. 20555; and to the Paperwork Reduction Project (3150-0101), Office of Management and Budget, Washington, D. C. 20503.
Thank you for your consideration in this matter.
If you have any questions regarding the examination procedures and requirements, please contact me at (215) 337-5210.
Sincerely.
Ortstaal Signed PY:
hkfdl W
uter W. EselgrotW, Chief Pressurized Water Reactor Section Operations Branch Division of Reactor Safety
Enclosures:
1.
Reference Material Requirements for Senior Reactor Operator Licensing Examinations 2.
Requirements for Administration of Written Examinations 3.
NRC Rules and Guidelines for Written Examinations 4.
Requirements for Facility Review of Written Examinations cc w/ enc 1:
M. L. Moore, Reactor Facility Director Dr. William Vernetson, Director of Nuclear Facilities, University of Florida Public Document Room (PDR)
Local Public Document Room (LPDR)
Nuclear Safety Information Center (NSIC)
State of Maryland (2) 0FFICIAL RECORD COPY HUGHES/AFRRI 90-DAY /12/12/89 -
0002.0.0 s
12/15/89 n
^-
f-Defense Nuclear Agency 3
- .y bec w/ enc 1
['
ReDion I Docket Room (with concurrences) l J. Dyer, EDO i
-Chief Examiner i
Assigned Examiners
.0L Facility File i
Project Manager, NRR i
B Hughes Examiner DRS Files (3)'
bec w/o encis:
Management Assistant, DRMA i
t i
i DRL R DRS:RIf8 I
Hughes k
Esel roth <
/-
12/jf/89 12/p/89
, gdy 0FFICIAL RECORD COPY HUGHES/AFRRI 90-DAY /12/12/89 -
0003.0.0 12/15/89 s
i
ENCLOSURE 1 REFERENCE MATERIAL REQUIREMENTS FOR REACTOR / SENIOR REACTOR OPERATOR LICENSING EXAMINATIONS 1.
Existing learning objectives, Job Performance Measures and lesson plans 3
(including training unuals, plant orientation manual, system descript-i ions,reactortheory, thermodynamics,etc.)
A' copy of ce facility Job and Task Analysis (JTA), specifying the know-ledges.and abilities required of an operator at the facility.
Each parti-cular knowledge and/or ability will include an importance rating correlat-ing it to ensuring the health and the safety of the public.
If a JTA is not furnished, the Knowledges and Abilities Catalog for Nuclear Power Plant Operators, NUREG 1122 (1123) will be used to establish content' valid-ity for the examination.
All Job Performance Measures (JPMs) used to ascertain the competence of the operators in performing tasks within the control room complex and, as identified in-the facility JTAs, outside of the control room, i.e., local operations.
Training materials shall include all substantive written material used for preparing applicants for initial R0 and SRO licensing. Tne written mater-ial shall include learning objectives and the details presented during.
lectures, rather than outlines. Training materials shall be identified by plant and unit, bound, tabbed, and indexed.
FAILURE TO PROVIDE COMPLETE, PROPERLY BOUND AND INDEXED PLANT REFERENCE MATERIAL MAY RESULT IN THE-RETURN OF 1HE MATERIAL TO THE PERSON WHO IS THE HIGHEST LEVEL OF' CORPORATE MANAGEMENT WHO IS RESPONSIBLE FOR PLANY OPERATIONS (E.G., VICE PRESIDENT OF NUCLEAR OPERATIONS). ACCOMPANYING THE MATERIAL WILL BE A COVER LETTER EXPLAINING THE DEFICIENCIES IN THE REFERENCE MATERIAL AND THE FACT THAT THIS WAS THEl REASON THE EXAMINATIONS WERE CANCELLED OR POSTPONED. Train-ing materials which include the following shall be provided:
System description:. including descriptions of all operationally relevant flow paths, components, controls and instrumentation.
System training material should draw parallels to the actual proce-dures used for operating the applicable system.
Complete and operationally useful descriptions of all safety-system interactions and, where available, BOP system interactions under emergency and abnormal conditions, including consequences of anti-cipated operator error, maintenance error, and equipment failure.
Training material used to clarify and strengthen understanding of emergency operating procedures.
V
E
, :.1
-w 2
Comprehensive theory. material that includes fundamentals in the area of theory of reattor operation, thermodynamics, heat transfer and
_ fluid flow, as well as specific application to actual in plant com-ponents.
For example, mechanical theory material on pumps shall include pump theory as well as descriptions of how these principles-actually apply to major plant pumps and the systems in which they are installed (i.e., Reactor Coolant Pumps, all ECCS pumps, Recirculation pumps, Feedwater pumps and Emergency Feedwater pumps).
Reactor Theory material shall include descriptions that draw explicit ties between the fundamentals and the actual operating limits followed in-the plant (i.e., reactor theory material should contain explanations how principles relate to the actual curves used by operators to verify shutdown margin or calculate an ECP).
2.
Complete Proceduro Index (including surveillance procedures, etc.)
'3.
All Administrative Procedures (as applicable to reactor operation or safety) 4.
All integrated plant procedures (normal or general operating procedures)'
5.
All-emergency procedures (emergency instructions, abnormal or special pro-cedures) 6.
Standing orders (important orders that are safety related and may super-sede the regular procedures) 7.
Surveillance procedures (procedures that are run frequently, i.e. weekly or that can be run on the simulator)'
8.
Fuel-handling and core-loading procedures, (initial core-loading proce-
-dure, when appropriate) 9.
All annunciator / alarm procedures 10.
Radiation protection manual (radiation control manual or procedures) 11.
Emergency plan implementing procedures 12.
Technical Specifications (and interpretations, if available) for all units for which licenses are sought.
13.
System Operating Procedures
_14.
Piping and Instrumentation diagrams, electrical single-line diagrams, or o
flow diagrams
c
.;.^
v' I'
1 3
- 15. Technical Data Book, and/or Plant curve information as used by operators and facility precautions, limitations, and set points (PLS) for the facility 16.
Licensee Event Reports for the previous two years.
17.
Examination Question Bank specific to the facility training program which may be used in the written or operating examinations.
In particular, multiple choice questions for the written examination.
(Voluntary by licensee).
- 18. Additional material required by the examiners to develop examinations that meet the requirements of these standards and the regulations.
The above reference material shall be approved, final issues and shall be so marked.
If a plant has not finalized some of the material, the Chief Examiner shall verify with the facility that the most complete, up-to-date-material is-available and that agreement has been reached with the licensee for limiting changes before the administration of the examination, All procedures and reference material shall be bound with appropriate indices or tables of contents so that-they can be used efficiently.
Failure to provide complete,
. properly bound and indexed plant reference material could result in cancella-tion _or rescheduling of the examinations.
i I
1 l
l
?.
O
(
e-'
{
c ENCLOSURE 2 REQUIREMENTS FOR ADMINISTRATION OF WRITTEN EXAMINATIONS 1.
A single room shall be provided for administration of the written examina-tion..The location of this room and supporting restroom facilities shall-be such as to prevent contact with all other facility and/or contractor personnel during the written examination.
If necessary, the facility should make arrangements'for the use of a suitable room at a local school, motel, or other building. Obtaining this room is the responsibility of the licensee.
2.
Minimum spacing is required to ensure examination integrity as determined.
by the Chief Examiner.
Minimum spacing should be one applic. ant per table, with a three foot space between tables.
3.
Suitable arrangements shall be made by the facility if the applicants are
~
.to have lunch, coffee, or other refreshments. These arrangements shall comply with Item 1 above and shall be reviewed by the examiner and/or proctor.
- 4.
The-facility licensee shall provide pads of 8-1/2 by 11 inch lined paper in. unopened packages for each applicant's use in completing the examina-tion..The examiner shall distribute these pads to the applicants.
5.
Applicants may bring pens, pencils, calculators or slide rules into' the examination room. Only black ink or dark pencils should be used for writing answers to questions.
6.
The licensee shall provide one set of steam tables for each applicant.
The examiner-shall distribute the steam tables to the applicants. No wall charts, models, and/or other training materials shall be present in the examination room.
No other equipment or reference material shall be-allowed unless provided by the examiner.
l
g l
^
9[
ENCLOSURE 3
.NRC RULES AND GUIDELINES FOR WRITTEN EXAMINATIONS
- 1.
Check identification badges.
2.
Pass out examinations and all handouts.
Remind applicants not to review examination until instructed to do so.
L READ THE FOLLOWING INSTRUCTIONS VERBATIM:
During the administration of this examination the following rules apply:
1.
Cheating on the examination means an automatic denial of your application and could result in more severe penalties.
2.
After the examination has been completed, you must sign the statement on the cover sheet indicating that the work is your own and you have not received or given assistance in completing the examination. This must be done after you complete the examination.
READ THE FOLLOWING INSTRUCTIONS 3,
Restroom trips are to be limited and only one applicant at a time may leave. You must avoid all contacts with anyone outside the examination room to avoid even the appearance or possibility of cheating.
4.
Use black ink or dark pencil only to facilitate legible reproductions.
l
. 5.
Print your name in the blank provided in the upper right-hand corner of the examination cover sheet.
6.
Fill in the date on the cover sheet of the examination (if necessary).
7.
You may write your answers on the examination question page or on a separate sheet of paper.
USE ONLY THE PAPER PROVIDED AND DO NOT WRITE ON THE BACK SIDE OF THE PAGE.
8.
If you write your answers on the examination question page and you need more space to answer a specific question, use a separate sheet of the paper provided and insert it directly af ter the specific question. DO NOT WRITE ON THE BACK SIDE OF THE EXAMINATION QUESTION PAGE.
L 9.
Print your name in the upper right hand corner of the first page of each section of your answer sheets whether you use the examination question pages or separate sheets of paper.
Initial each pagc.
l l,
- 10. Before you turn in your examination, consecutively number each answer l
sheet, including any additional pages inserted when writing vour answers on the examination question page.
l.
1
4
~
s 2
1 11.
If you are using separate sheets, number each answer as to category-and number (i.e. 1.04,6.10) and skip at least 3 lines between answers to allow space for grading.
- 12. Write "End of Category
" at the end of your answers to a category.
13.
Start each category on a new page.
.14. Write "Last Page" on~the last answer sheet.
- 15. Use ' abbreviations only if they are commonly used in facility literature.
Avoid using symbols such as < or > signs to avoid a simple transposition error resulting in an incorrect answer. Write it out.
- 16. The point value for each question is indicated in parentheses after the question. The amount of blank space on'an examination question page is NOT an indication of the depth of answer required.
17.
Show all calculations, methods, or assumptions used to obtain an answer.
18.
Partial' credit may be given for other than aultiple choice questions.
Therefore, ANSWER ALL PARTS OF THE QUESTION AND 00 NOT LEAVE ANY ANSWER BLANK.
- 19. Partial credit will NOT be awarded for questions using multiple choice selection formatting.
The correct answer must stand on its own merit.
20.
Proportional grading wi11 be' applied. Any additional wrong information that is provided may count against you.
For example, if a question is worth one. point-and asks for four responses, each of which is worth 0.25 points, and you give five responses, each of your responses will be worth 0.20 points.
If one of your five responses is incorrect, 0.20 will be deducted and your total credit for that question will be 0.80 instead of
-1.00 even though you got the four correct answers.
21.
If the intent-of a question is unclear, ask questions of the examiner only.
12 2. When turning in your examination, assemble the completed examination with examination questions, examination aids and answer sheets.
In addition, turn in all scrap paper.
- 23. To pass the examination, you must achieve an overall grade of 80% or greater and at least 70% in each category.
24.
Ensure that all information you wish to have evaluated as part of your answer is on your answer sheet.
Scrap paper will be disposed of without review immediately following the examination.
/
3
- 25. There is a time limit of (6) hours for completion of the examination -(or some other time if less than the full examination is taken).
- 26. When you are done and have turned in your examination, leave the examina-tion area (DEFINE THE AREA).
If you are found in this area while the examination is still in progress, your license may be denied or revoked.
t
, - =
p,,.
e-
- d. ',
ENCLOSURE 4 REQUIREMENTS FOR FACILITY REVIEW 0F WRITTEN EXAMINATIONS 1.
At the option of the Chief Examiner, the' facility may review the written examination up to two weeks prior to:its adminictration.
This review may C
take place at the facility or in the Regional office. The Chief Examiner-will. coordinate the details of the. review with the facility. An NRC exam-iner will always be present during the review.
When this option of examination review is utilized, the facility reviewers will sign the following statement prior to being allowed access to the examination.
The examination or written notes will not be retained by the facility.
a.
Pre-Examination Security Agreement I
agree that I will not knowingly divulge any informa-tion concerning the replacement (or initial) examination scheduled for to any unauthorized persons.
I understand that I am.not to participate in any instruction involving those reactor operator or senior reactor operator applicants scheduled to be admini-stered the above replacement (or initial) examination from now until after the examination has been administered.
I understand that viola-tion of this srcurity agreement could result in the examination being voided.
Signature /Date In addition, the facility. staff reviewers will sign the following statement after the. written examination has been administered, b.
Post-Examination Security Agreement I
did not, to the best of knowledge, divulge any information concerning the written examination administered on to any unauthorized persons.
I did not participate in providing any instruction to those reactor opera-tor and senior reactor operator applicants who were administered the examination from the time that I was allowed access to the examination.
Signature /Date l
l I
l l
rar
~
q 2
f 2.
Regardless of whether the above examination review option is exercised, immediately following the administration of the written examination, the facility staff shall be provided a marked up copy of the examination and the answer key. The copy of the written examination shall include pen and ink changes made to questions during the examination administration.
If the facility did not review the examination prior to its administra-tion, they will have five (5) working days from the day of the written examination to submit formal comments.
If the facility reviewed the examination prior to its administration, any additional comments must be
^
given to an examiner prior to his/her leaving the site at.the end of the week of the written examination administration.
In either case, the comments will be addressed to the responsible Regional Office by the highest on site level of corporate management for plant operations, e.g.,
i Vice President for Nuclear Operations. A copy of the submittal will be forwarded to the Chief Examiner, as appropriate.
Comments not submitted within the required time frame will be considered for inclusion in the
. grading. process on a case-by-case basis by the Regional Office Section Chief.
Should the comment submittal deadline not be met, a long delay in gr: ding the examination may occur.
3.
The following format should be' adhered to for submittal of specific comments:
-a.
Listing of NRC Question, answer and reference b.
Facility comment / recommendation c.
Reference (to support facility comment)
NOTES:
1.
No change to the examination will be made without submittal of of a reference to support the facility comment. Any supporting documentation that was not previously supplied, should be provided.
2.
Comments made without a concise facility recommendation will not be addressed.
4.
A two hour post examination review may be held at the discretion of the Chief Examiner.
If this review is held, the facility staff should be informed that only written comments that are properly supported will be considered in the grading of the examination.
1 i
.