,_

Detroit Edison M175==

August 31, 1981 EF2 - 54,388 Mr. L. L. Kintner Division of Project Management Office of Nuclear Reactor Regulation U.

S. Nuclear Regulatory Commission Washington, DC 20555

Reference:

Enrico Fermi Atomic Power P'. ant - Unit #2 NRC Docket No. 50-341

Subject:

High Density Fuel Racks:

Reassessment for Site Specific Earthquake

Dear Mr. Kintner:

Attached is a copy of subject report:

Joseph Oat Corporstion, Oat J#7025/J#2437, Report #TM-614 (P. 1 to 12 and Appendix A.:

P.

1 to 36).

This report presents results of analysis which was conducted to verify the expected values of significant paismeters that were submitted to you in EF2 - 53,811 of June 26, 1981.

Sincerely, f5 e

William F.

Colbert Technical Director Enrico Fermi 2 WFC/YNA/jlj Attachment f

s

/ W 8109020233 810831 PDRADOCK0500g

- -